Notifier AFP-400 Operating Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-afp-400-operating-instructions-7682409531.pdf |
---|---|
Type | |
Size | 947.30 KB |
Downloads |
Text Preview
AFP 400 OPERATING INSTRUCTIONS sheet must be framed and mounted adjacent to the control panel Operating Information STANDBY OPERATION Green AC POWER indicator lit steadily Red ALARM indicator off Yellow TROUBLE indicators off CONDITION Red ALARM indicator lit Alarm signaling devices activated Option module remote station or supplementary alarm relay activated Alarm information visible on LCD display RESET locating and correcting the alarm condition reset the control by pressing the SYSTEM RESET switch CONDITIONS of trouble signal under normal operation indicates a that requires immediate attention Contact your local representative Silence the audible signal by pressing the switch The Trouble indicator will remain Switch Functions silences the piezo sounder and changes all flashing to steady Only one press is necessary regardless of number of new alarms troubles or supervisory signals If piezo is silenced it sends an ACKNOWLEDGE message to printer and history file ACKNOWLEDGE also automatically a special command to silence piezo sounders on the and ACS Annunciators If more than one event exists it the display to the next item and displays it for seconds or until the ACKNOWLEDGE STEP key is pressed Step function SILENCE Silence performs all the functions of ACKNOWLEDGE In if an alarm exists it turns off all silenceable circuits and the ALARM SILENCE indicator It also sends an SILENCED message to the printer and history file A alarm will then resound the system This unit is programmed to inhibit signal silence for seconds This unit is programmed to automatically silence alarm signal after minutes ACTIVATE AFP 400 waits for the ALARM ACTIVATE switch to be for 2 seconds to prevent accidental activations then on all silenceable circuits all CMX 1 modules bell circuits are programmed silenceable and turns off the ALARM LED It sends a Manual Evacuate message to the display LCD 80 printer and History file RESET the control panel TEST and hold the switch to lamp test the LEDs LED Indicators POWER LED which illuminates when primary power is applied to the panel ALARM LED that flashes when one or more alarms occur Illuminates after alarms are acknowledged and turns off when is pressed after alarm clears WARNING LED that flashes when a pre alarm threshold is reached 80 character LCD display indicates if it is an ALERT or pre alarm optional LED that illuminates for a security alarm LED turns off after alarm clears and RESET is pressed optional LED that flashes when a Supervisory Hazard Alert or condition occurs such as a sprinkler valve tamper The LED turns off when the Supervisory condition The Hazard Alert or Tamper indication will latch until reset TROUBLE LED that flashes when one or more troubles occur Goes steadily when ACKNOWLEDGE is pressed and turns off when trouble conditions are cleared Will illuminate if the micropro watchdog timer fails CPU FAIL POINTS LED that illuminates when one or more points are disabled 80 character LCD will indicate which points have been Turns off when points are re enabled SILENCED LED that illuminates after ALARM SILENCE has been Turns off when ALARM ACTIVATE or SYSTEM RESET pressed Audible Tone Indicator continuous sounding tone slow pulsating tone signal having an equal on and off time fast pulsating tone signal having an equal on and off time Periodic Testing and Maintenance ensure proper and reliable operation system inspection and should be scheduled monthly or as required by NFPA 72H local fire codes A qualified Service Representative should testing TESTING fire department and or central alarm receiving station if condition is transmitted Notify facility personnel of the test alarm sounding devices are ignored during the test period TESTING all fire central station and or building personnel when is complete SERVICE REPRESENTATIVE 50364 Rev A ECN 95 447 10 23 95 of 2 The following section applies to voice and telephone systems only Audio Telephone System Information Audio Message Generator Level This green LED is illuminated when the audio level is correct Call This green LED toggles ON and OFF with each press of the All Call switch Line This green LED normally illuminates to show that the control panel is with the Audio Message Generator This yellow LED illuminates to indicate the presence of a trouble local to the equipment AMG FFT and amplifiers Call switch The All Call switch when pressed is used to activate all speaker circuits speaker circuits will deactivate when the All Call switch is pressed toggle function provided an alarm is not present If an alarm is the speaker circuits remain active until manually turned off or until system is reset In dual channel applications press either All Call switch the same result Volume The local speaker volume control adjusts the volume of the speaker located on the AMG It will not affect volume of the speakers installed throughout the facility If necessary turn the volume down to prevent during paging operations The microphone is used for paging operations To page select the speaker circuit s that you wish to page by using the control switches on the VCM DCM or ACS or by using the All Call switch on the AMG the switch on the side of the microphone and speak into the microphone Talk loudly enough to cause green Audio Level LED to illuminate If the Audio Level LED remains off for 30 seconds a system will result Select Circuit Select To turn a speaker circuit on press the control button for a specific speaker circuit on the VCM DCM or The LED for the circuit selected will illuminate The control button toggles the state of this circuit select an audio output function voice message or audio tone press the control button Note An active function may have to be deactivated before selecting the next function select a channel press the control button for the desired channel The LED on that point will illuminate control button toggles the selection of the channel Channels must be selected for each speaker zone a dual channel system Select Audio Tone Generator Line This green LED normally illuminates to show that the control panel is with the Audio Message Generator Channel This green LED illuminates to show that manual paging will occur over the Channel This green LED illuminates to show that manual paging will occur over the Channel Channel This yellow LED illuminates to indicate the presence of a trouble local to the equipment AMG FFT and amplifiers Select switch The Page Select switch when pressed is used to choose between EVAC and channels for paging The respective LED will illuminate when that is selected The microphone is used for paging operations To page select the speaker circuit s that you wish to page by using the control switches on the VCM DCM or ACS or by using the All Call switch on the AMG the switch on the side of the microphone and speak into the microphone Talk loudly enough to cause green Audio Level LED to illuminate If the Audio Level LED is allowed to remain off for 30 seconds a trouble will result Circuit Select To turn a speaker circuit on press the control button for that specific speaker circuit on the VCM DCM or The LED for the circuit selected will illuminate The control button toggles the state of this circuit and FFT 7S Fire Fighters Telephone Mode FFT 7 only The green LED will illuminate when the Page switch is depressed Line This green LED will illuminate to show that power is applied to the Trouble This yellow LED illuminates to indicate an internal circuit trouble Trouble This yellow LED illuminates to indicate an external circuit trouble switch The Page switch allows the firefighter to page from the FFT To page the speaker circuits that will carry the page by using the control or by using the All Call switch on the adjacent AMG 1 Press the switch and talk loud enough into the handset to cause the green level LED on the AMG 1 to illuminate Calls The green LED on the VCM mapped to a telephone circuit will flash and the piezo will beep DO NOT THE ACKNOWLEDGE BUTTON IN THIS CASE To answer the incoming call pick up the master and press the control button Wait until the caller is connected audible click in the receiver To the call momentarily press the telephon