Notifier AM2020 AFP1010 with SIB-NET Installation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-am2020-afp1010-with-sib-net-installation-0623948175.pdf |
---|---|
Type | |
Size | 1.19 MB |
Downloads |
Text Preview
AM2020 AFP1010 SIB NET 15094 Rev 15094 C ECN 95 210 Precautions Adherence to the following will aid in problem free installation with long term reliability Several different sources of power can be connected to fire alarm control panel Disconnect all sources of power before Control unit and associated equipment may be damaged by and or inserting cards modules or interconnecting cables the unit is energized Do not attempt to install service or operate unit until this manual is read and understood all solid state electronic devices this system may operate or can be damaged when subjected to lightning induced Although no system is completely immune from lightning and interferences proper grounding will reduce susceptibility or outside aerial wiring is not recommended due to an susceptibility to nearby lightning strikes Consult with the Services Department if any problems are anticipated or System Reacceptance Test after Software Changes To proper system operation this product must be tested in accor with NFPA 72 1993 Chapter 7 after any programming operation change in site specific software Reacceptance testing is required any change addition or deletion of system components or after any repair or adjustment to system hardware or wiring components circuits system operations or software functions to be affected by a change must be 100 tested In addition to that other operations are not inadvertently affected at least 10 initiating devices that are not directly affected by the change up to a of 50 devices must also be tested and proper system opera verified system meets NFPA requirements for operation at 0 49O C at a relative humidity of 85 RH non condensing 30OC the useful life of the system standby batteries and the components may be adversely affected by extreme tem ranges and humidity Therefore it is recommended that this and its peripherals be installed in an environment with a room temperature of 60 80O F AC power and batteries prior to removing or inserting boards Failure to do so can damage circuits all electronic assemblies prior to any drilling filing reaming punching of the enclosure When possible make all cable entries from sides or rear Before making modifications verify that they will not with battery transformer and printed circuit board location not tighten screw terminals more than 9 in lbs Over tightening damage threads resulting in reduced terminal contact pressure difficulty with screw terminal removal system contains static sensitive components Always ground with a proper wrist strap before handling any circuits so that charges are removed from the body Use static suppressive to protect electronic assemblies removed from the unit the instructions in the installation operating and program manuals These instructions must be followed to avoid damage to control panel and associated equipment FACP operation and depend upon proper installation that wire sizes are adequate for all initiating and indicating loops Most devices cannot tolerate more than a 10 I R drop the specified device voltage Alarm System Limitations While installing a fire alarm system may make lower insurance rates it is not a substitute for fire insurance automatic fire alarm system typically made up of smoke detectors detectors manual pull stations audible warning devices and a fire control with remote notification capability can provide early warn of a developing fire Such a system however does not assure against property damage or loss of life resulting from a fire fire alarm system may fail for a variety of reasons detectors may not sense fire where smoke cannot reach the such as in chimneys in walls or roofs or on the other side of doors Smoke detectors also may not sense a fire on another or floor of a building A second floor detector for example may not a first floor or basement fire Furthermore all types of smoke both ionization and photoelectric types have sensing limita No type of smoke detector can sense every kind of fire caused by and safety hazards like smoking in bed violent explosions gas improper storage of flammable materials overloaded circuits children playing with matches or arson Smoke detectors must be installed in the same as the control panel and in rooms used by the system for the of alarm transmission wiring communications signal and or power If detectors are not so located a developing fire damage the alarm system crippling its ability to report a fire Warning This equipment generates uses and can radiate radio energy and if not installed and used in accordance with the manual may cause interference to radio communications It has tested and found to comply with the limits for class A computing pursuant to Subpart B of Part 15 of FCC Rules which is designed provide reasonable protection against such interference when operated a commercial environment Operation of this equipment in a residential is likely to cause interference in which case the user will be required correct the interference at his own expense warning devices such as bells may not alert people if these are located on the other side of closed or partly open doors or located on another floor of a building fire alarm system will not operate without any electrical power If AC fails the system will operate from standby batteries only for a time heat detectors may be subject to reduced sensitivity time For this reason the rate of rise feature of each detector be tested at least once per year by a qualified fire protection used in the system may not be technically compatible with control It is essential to use only equipment listed for service with control panel lines needed to transmit alarm signals from a premise to a monitoring station may be out of service or temporarily disabled most common cause of fire alarm malfunctions however is maintenance All devices and system wiring should be and maintained by professional fire alarm installers following procedures supplied with each device System inspection and should be scheduled monthly or as required by National and or fire codes Adequate written records of all inspections should be Requirements digital apparatus does not exceed the Class A limits for radiation emissions from digital apparatus set out in the Radio Interference of the Canadian Department of Communications present appareil numerique n pas de bruits radioelectriques les limites applicables aux appareils numeriques de la classe prescrites dans le Reglement sur le brouillage radioelectrique edicte par ministere des Communications du Canada 11 02 95 of Contents 1 Installing the Serial Interface Board for the AM2020 AFP1010 4 4 1.1 Related Documentation 5 1 1 1 1 with 1 SIB NET Chip 6 1.2 Mounting the Interconnect Chassis Assemblies 6 1 2 Mounting the ICA 4L and System Boards 7 1 3 Two ICA 4Ls using Expansion Power Cable 75142 8 1.3 Mounting the Serial Interface Board 9 Terminal Designations 10 1 4 CRT Terminal 11 1.4 1 5 to SIB Connections 12 1.5 Remote Printers 13 Printer to SIB Connections 13 1 6 Printer Connections 14 1 7 1 8 to SIB NET Connections 15 A Circuit Devices Ratings