Notifier AROM6N for the AFP1010 ROM Inventory List

File Preview
File Preview
Click below to download for free

File Data

Name notifier-arom6n-for-the-afp1010-rom-inventory-list-9508342716.pdf
Type PDF
Size 1.21 MB
Downloads

Text Preview

12 Clintonville Road CT 06472 1610 FAX 203 484 7118 Release Summary the Notifier AFP1010 Control Panel the DIA 1010 Interface Assembly AROM6N document covers AFP1010 Release 6.0 Software as affects the following ROMS AROM6N AMGZC AROM6N LIB B System Reacceptance Test after Software Changes To ensure proper system operation this product must be tested in accordance NFPA 72 1993 Chapter 7 after any programming operation or change in site specific software Reacceptance testing is required after any addition or deletion of system components or after any modification repair or adjustment to system hardware or wiring components circuits system operations or software functions known to be affected by a change must be 100 tested In addition to ensure other operations are not inadvertently affected at least 10 of initiating devices that are not directly affected by the change up to a maximum 50 devices must also be tested and proper system operation verified 15538 Revision H1 15538 H1 ECN 97 294 List following replacement ROMs must be ordered individually according to your system requirements AROM6Ns and A1ROM6Ns cannot be in conjunction with earlier ROMs All system ROMs must be upgraded at the same time See Compatibility Warning standard AMG operation at Annunciator address 29 30 31 or 32 for AMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm for the AM2020 and AFP1010 for use with 5th through 8th AMG in one system at address 25 26 27 or 28 forAMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm for the AM2020 and AFP1010 zone coded AMG operation occupying addresses 2 3 4 and 5 for AMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm Multiplex for the AM2020 and AFP1010 zone coded AMG operation occupying addresses 2 3 4 and 5 for AMG 1 AMG E 15744 15889 Change Procedure for the AM2020 and AFP1010 Alarm Multiplex for the AM2020 and AFP1010 Change Procedure for the AM2020 and AFP1010 AM2020 AFP1010 Fire Alarm Control Panel Operator Instructions Label Instruction Sheet Change Procedure for the AM2020 and AFP1010 AM2020 AFP1010 Manual to Document 15088 for LIB 200 15744 Change Procedure for the AM2020 and AFP1010 for CPU 2 15744 15337 for DIA 1010 Label 15987 15744 15088 15088SUP for SIB 2048 15744 for XPP 1 15744 15888 15538 H1 07 21 97 Change Procedure for the AM2020 and AFP1010 Change Procedure for the AM2020 and AFP1010 XP Series Transponder System EPROM Part 73284 73295 73529 73534 73550 73548 73539 73540 73496 73679 P N 73548 Label Provides a reference to the ROM soft level currently installed in AFP1010 DIA 1010 assem Place this label on the inside of DIA 1010 door during installa of the A1ROM6N DIA Mylar Security Overlay software is upgrad to this level the label above must be over the existing LED legend if existing legend differs the above AROM6N and A1ROM6N Special Features Notes Drift feature makes the NFPA 72 1993 6 sensitivity calibrated test for detectors software selectable When the software provided with upgrade kit is installed the NFPA Chapter 6 Sensitivity Calibrat Test and Drift Compensation fea will be automatically disabled installer must re enable Drift Com See the AM2020 AFP1010 Manual Document 15334 order to restore the NFPA 72 1993 6 Sensitivity Calibrated Test Drift Compensation features Security feature allows the AM2020 AFP1010 act as a combination fire security protec signaling system The AM2020 is suitable for use as a Grade AA A or Grade B Central Station and Burglar Alarm Protected Pre and Receiving Unit only after all requirements outlined and pro guidelines described in the manuals have been to This feature utilizes four new type IDs SARM SACM SSYM SEQM in addition to a new control by function SDEL Revised Standard for Operation Fire Alarm Control Panel must the reporting of A C power loss the digital alarm communicator A software type ID DACT is used a CMX control module to accom this Coded Voice Female female zone coded voice the AMG requires the installation of both an chip and a VROM chip 15538 H1 07 21 97 3 Warning Combinations All software part numbers are not compatible with each other mixing of software part numbers may compromise LifeSafety functions If in doubt the compatibility of a particular software combination consult the factory AMNET and AUTOPLEXOR software is not compatible with earlier versions of CGAS AMNET and AUTOPLEXOR systems Software in these items must be upgraded compatibility AFP1010 Software Releases following features are included in the current software release Rev A Selectable Drift Compensation UL1076 UL1610 Security Rev B E UL 864 Revised Standard for DACT Rev F G Zone Coded Voice Female Rev A Battery Charger Control Block Acknowledge Control By Time Control Module Reporting Day Night Sensitivity Device Blink Disabled Zones Event Reminder Expanded Read Status Functions Expanded AMG Addressing Expanded Status Line Expanded User Reports LED Latching Local Printer New Type I D NIB Trouble Reporting Non Alarm Module Reporting Periodic Detector Test Prior Next Autostep Keys Remote Page Verification Counter Reset Walk Test Zone Coded Synthesized Chime Zone Coded Voice Rev B cid 127 New AMG Boards Rev C E 72E Sensitivity Calibrated Test Drift Compensation Manual Reset of automatically activated control modules 15538 H1 07 21 97

Related Files