Notifier N-ANN-RLY Relay Module

File Preview
File Preview
Click below to download for free

File Data

Name notifier-n-ann-rly-relay-module-5186432790.pdf
Type PDF
Size 701.38 KB
Downloads

Text Preview

N ANN RLY Module N ANN RLY relay module provides 10 programmable relays when used with a compatible FACP Fire Alarm Panel The N ANN RLY module may be mounted the FACP main circuit board chassis or in the battery of the enclosure using optional mounting bracket P N Reference Installation Instructions document N ANN RLY and the FACP communicate over a two wire interface employing the ANN BUS communication for An additional two wires are used for 24 volt DC power A four conductor unshielded cable may be used for both and data communications to eight ANN BUS devices may be connected to the ANN of each FACP N ANN RLY connects to the ANN BUS terminal on the and requires minimal programming Provides 10 programmable Form C relays Ten Form C relays can be programmed for various func Alarm Trouble Supervisory AC Loss Waterflow Input Zones and Silenceable Alarm Compatible with the NFW 50 C NFW2 100 C SFP RP 2001 C RP 2002 C and SFP 10UD C May be powered by 24 VDC from the host FACP or by power supply requires 24 VDC Up to eight ANN BUS devices may be connected to the of each FACP Listed to UL Standard 864 9th Edition Maximum ANN BUS Voltage 24 VDC Maximum Current Alarm 75 mA Standby 15 mA Ambient Temperature 32 to 120 0 to 49 Relative Humidity 93 2 RH noncondensing at 32 2 90 3 For use indoors in a dry location Connections to FACP are power limited and supervised Relay Contact Ratings 2 Amps 30VDC Resistive 0.5 30VAC Resistive Listings and Approvals listings and approvals below apply to the N ANN RLY In cases certain modules may not be listed by certain agencies or listing may be in process Consult fac for latest listing status UL S635 FM Approved Fire Dept of New York COA 6177 CSFM 7165 0028 0245 7165 0028 0246 K 20 ANN BUS THE DEVICES ON THE ANN BUS FROM POWER SUPPLY devices can be powered by an auxiliary power sup when available panel power is exceeded See FACP man for information DEVICE ADDRESSING ANN BUS device requires a unique address ID Num in order to communicate with the FACP A maximum of devices can be connected to the FACP ANN BUS com circuit See the FACP manual for more information REQUIREMENTS N ANN RLY connects to the FACP ANN BUS communica circuit To determine the type of wire and the maximum distance calculate the total worst case current draw for modules on a single 4 conductor bus Use the table on the page to determine the maximum distance the mod can be located from the FACP In general the wire length limited by resistance but for heavier wire gauges capaci is the limiting factor These cases are marked in the with an asterisk Maximum length can never be more 6,000 feet 1,800 m regardless of gauge used to the appropriate FACP manual for wiring details Information ANN RLY Relay Module provides 10 programmable Form relays ANN MBRLY Optional mounting bracket required for Fire applications ROME Relay Option Module Enclosure includes one Relay module and one ANN MBRLY bracket 11 3 14 Page 1 of 2 Pair Wiring Distance FACP to last ANN BUS Module Worst Case Draw amps Gauge Gauge Gauge Gauge max ft 565 m ft 282 m ft 188 m ft 141 m ft 113 m ft 94 m ft 81 m ft 70 m ft 63 m ft 56 m ft 1,429 m ft 715 m ft 476 m ft 357m ft 286 m ft 238 m ft 204 m ft 179 m ft 159 m ft 143 m 6,000 ft 1,829 m ft 1,137 m ft 758 m ft 569 m ft 455 m ft 379 m ft 325 m ft 284 m ft 253 m ft 227 m 6,000 ft 1,829 m ft 1,800 m ft 1,200 m ft 900 m ft 720 m ft 600 m ft 514 m ft 450 m ft 400 m ft 360 m to FACP ANN BUS or next device to FACP or UL listed Power Supply for Protective Signaling and or next device Relay Module by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 7107 B 11 3 14

Related Files