Notifier N-MPS and NFW-MPS Conventional Series Manual Stations

File Preview
File Preview
Click below to download for free

Text Preview

N MPS and NFW MPS Series Stations Notifier MPS Conventional Series manual stations provide for the NFS 320C NFS2 640 and NFS2 3030 fire control panels NFW MPS series manual stations provide for FireWarden series panels These high quality die metal manual stations include screw terminal connections integrated break glass rod The alarm contact for the man station is rated for 1A 24VDC The contacts are gold plated avoid the risk of corrosion MPS Series manual stations are available as single or two for conventional systems Models N MPS SC SCC are manual stations Models N MPS 2C 2CC two models are similar to the N MPS SC single stage mod except they contain an additional 2nd Stage normally open A 2nd stage key is supplied with each unit to activate 2nd Stage key switch models are available with screw terminal connectors and a key for reset Two stage models also include a key switch 2 keys All conventional models mount on a single gang or on a single gang box with a plaster ring surface mounting use Notifier surface back box MPS BB all conventional manual stations Notifier MPS Series manual stations are operated by pulling handle on the front of the station To reset the manual sta open the manual station with the hex key provided and the handle in the normal upright position Replace the rod and close the manual station front cover N MPS two stage models include a key switch which is above the handle Operation of the key switch when to a separate alarm initiating circuit will activate the stage of a two stage alarm signaling system reset the second stage activation return the key switch to the position before resetting the fire alarm control panel provided with an ancillary contact for mag lock release simultaneously release the locally connected mag lock upon the handle on the front of the manual station break glass Constructed of high quality die cast metal Highly visible red enamel finish English and French lettering Single action pull lever design Optional dual action lever kit Hex key resettable Screw terminal connectors Optional ancillary contact for local mag lock release Single stage and two stage models Key switch activation for second stage Surface or semi flush mounting All conventional models mount on a standard single gang box or a surface metal back box DN 5497 C1 Initiating Devices manual station is the Notifier N MPS series Operating appear in English and French lettering The unit is of high quality die cast metal and finished in red paint to be easily identified When the handle is pulled manual station initiates an immediate operation of the alarm circuit In addition those manual stations installed in a system are equipped with a key switch designed to the second stage alarm initiating circuit Manual stations have the option of an ancillary contact for local mag lock Manual stations are listed with Underwriters Laborato Canada ULC Manual stations are required to be installed the current Canadian Electrical Code and the current CAN S524 Standard for the installation of Fire Alarm Sys and comply with CAN ULC S528 Manual Stations for Alarm Systems Including Accessories Manual stations be installed within the limits defined by the national local Final acceptance is subject to the local authority jurisdiction stations are provided with a hex key reset lock reset the device after the manual station has been operated to allow access for testing The stations are designed so after an actual emergency operation the stations cannot be to normal operation without the use of the supplied hex The manual stations are provided with an integrated break feature addition of the dual action adapter cover MPS LP requires operator to first lift the cover and then pull the handle of the station conventional models mount on a single gang box or on a sin box with a plaster ring surface mounting use Notifier surface back box MPS BB conventional manual stations DN 5497 C1 06 22 2010 Page 1 of 2 Listings and Approvals ULC listed S7568 CONVENTIONAL MODELS Applied Voltage 32 VDC Voltage Nominal 24 VDC Current Consumption 400uA Single stage ver 550 uA Two stage versions Current Consumption 550 uA Single stage ver 1100 uA Two stage versions Temperature Range 0 to 49 10 to 93 noncondensing 121mm H x 82mm W x55mm D 499 Grams Single stage version 567 Grams Two stage MODELS WITH ANCILLARY CONTACTS Contact Ratings 30 VAC 6 amps Resistive 6 amps Inductive 30 VDC 6 amps Resistive 3 amps Inductive All models are for use indoors in a dry location Line Information MANUAL STATIONS Conventional single stage manual station English lettering Conventional single stage manual station alarm and ancillary contacts included English French Conventional single stage manual station Blue in English French lettering Conventional two stage manual station English lettering Conventional two stage manual station Form C and ancillary contacts included English French lettering addressable manual stations see DN 60629 Lift pull dual action adapter cover for use with the Series manual stations English French lettering Mounting plate for semi flush mounting addressable stations to a 4 square electrical box red Mounting plate for semi flush mounting addressable stations to a two gang electrical box red Surface back box use with conventional x 82.5mm W x 44.5mm D 4.88 H x x 1.75 D Extension ring for addressable models using existing electrical boxes Replacement break glass rods Package of 10 Replacement Hex Key Replacement 2nd Stage Key is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for purposes We try to keep our information up to date and accurate We cover all specific applications or anticipate requirements All specifications are subject to without notice more information contact Notifier 289 1114 Whitmore Road Ontario L4L 7Z4 2 of 2 Canadian DN 5497 C1 06 22 2010

Related Files