Notifier NCD Datasheet

File Preview
File Preview
Click below to download for free

File Data

Name notifier-ncd-datasheet-6940178532.pdf
Type PDF
Size 1.29 MB
Downloads

Text Preview

NCD Network Control Display Network Control Display NCD is the next generation of net control annunciators for the NOTI network With new modern contemporary design the NCD meets today build aesthetic needs The intuitive 1024 x 600 10 touch screen pro detailed color coded system status and point information It is with NOTIFIER INSPIRE and ONYX series fire alarm panels FACP and nodes such as the INSPIRE N16e x ACM 30 annunciator and RLD remote display as well as the NFS2 3030 NFS2 640 and NFS 320 FACPs NCD provides system control and status history display capabil for all or for selected network nodes It can also be used as the display for control and status capabilities on a displayless via Direct Connect Features Full supervision of all inputs and network integrity High definition 10 1024 x 600 color touchscreen display LED status indicators for power and off normal Requires 24 VDC and a network connection or direct connect Three USB 2.0 connections USB C USB Micro and USB A Trouble Relay Tamper and Trouble inputs Features Device information including point address and description can quickly identified Summary Event Count display and event handling user guidance program Network wide Acknowledge Silence Reset Lamp Test Fully programmable node mapping subsystem Up to 2000 programmable logic zones Up to 32 custom action buttons Environmental adjustment controls to maximize display legibility Color coded Icon based event notification Can be used as FACP primary display Supports standard and high speed network systems Event vectoring for quick viewing of event groups Virtual alphanumeric QWERTY keypad and numeric keypad dis when data input is needed Enable Disable or group Enable Disable for networked and INSPIRE series panels Control ON OFF for networked ONYX and INSPIRE series panel Read Status networked ONYX and INSPIRE series panel points points zones History Buffer 10,000 events 3000 displayed Up to 50 unique users and 5 different user levels Read Status from event display History filters for report displaying Timer control for Auto Silence AC Fail Delay Custom wallpaper Indicators and Controls INDICATORS LED illuminates when 24 VDC power is applied When on backup the green LED will not illuminate LED illuminates when an off normal condition exists EVENT INDICATORS FIRE ALARM red illuminates when at least one fire alarm event CO Alarm blue illuminates when at least one CO alarm event SUPERVISORY yellow illuminates when at least one supervi event exists i e sprinkler valve off normal low pressure pump running guard tour etc TROUBLE yellow illuminates when at least one trouble event POINT DISABLED yellow illuminates when at least one disable on the network or in the system OTHER varies illuminates for SECURITY PRE ALARM CO and CRITICAL PROCESS SIGNALS SILENCED yellow illuminates if the NCD Silence point has been pressed or if any other node sent a Network command 10 15 2021 Page 1 of 2 TOUCHPOINTS Menu Login Acknowledge Signal Silence System Reset Drill Acknowledge Tap this touchpoint to acknowledge off all events Signal Silence Tap this touchpoint to turn off all control notification appliance circuits and panel output circuits have been programmed as Silenceable System Reset Tap this touchpoint to clear all latched and other events and clear event indicators Hold this touchpoint down for two seconds to activate all output circuits NOTE when enabled the drill touchpoint be displayed in the Alert Bar FUNCTION TOUCHPOINTS function touchpoint are accessible though the menu dialogs ABOUT tap this touchpoint to view current firmware and hard revision numbers DISPLAY tap this touchpoint to adjust display settings LAMP TEST tap this touchpoint to test display pixels LED indi and piezo Line Information Network Control Display Requires a network communications NCM for networking In direct connect applications the is not required NCM F Standard Network Communications Modules Wire multi mode fiber versions available See DN 6861 High speed network modules Wire single mode fiber multi mode fiber media conversion models are available See DN 60454 Ten inch display annunciator Backbox Surface or red Mounts NCD and one network control module Series Enclosure Available in four sizes through and door ordered separately requires BP2 4 battery plate DN 6857 Series Enclosure Available in five sizes through and door ordered separately requires BP 5 battery dress See DN 62113 Graphic Annunciator Dress Plate Dress plate is used the 10 graphic display is mounted in CAB 4 Series cabinet top row Graphic Annunciator Dress Plate Dress plate is used the 10 graphic display is mounted in the top row of a CAB 4 cabinet Graphic Annunciator Dress Plate Dress plate is used the 10 graphic display is mounted in any row of a CAB 5 cabinet Listings and Approvals file number s below reference the specific listings for the mod in this document In some cases certain modules or applica may not be listed by certain approval agencies or listing may in process Consult factory for latest listing status Listed S635 Approved 7165 0028 0516 COA 001761 and Codes listings and approvals below apply to the NCD In some certain modules or applications may not be listed by certain agencies or listing may be in process Consult factory for listing status UL 864 10th edition NFPA 72 National Fire Protection Association AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 to 49 to 120 and at a relative humidity non condensing of 85 30 86 per NFPA However the useful life of the system batteries and the electronic components may be adversely by extreme temperature ranges and humidity Therefore it recommended that this system and all peripherals be installed in environment with a nominal room temperature of 15 to 27 to 80 lbs 1.36 kilograms REQUIREMENTS NCD may be powered from any UL Listed non resettable 24 source from a NOTIFIER compatible fire panel see panel data Power source 1 AMPS 24 120 VAC 50 60 Hz or AMPS 240 VAC 50 60 Hz power supply 2 the NFS2 640 and NFS on board power supply 3 the N16 on board power supply or a or 4 a supervised 24 VDC power supply that is UL for fire protective service The current consumption of the NCD 360 mA Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice INSPIRE and NOTI are trademarks of and ONYX and INSPIRE are registered trademarks of Hon International Inc by Honeywell International Inc All rights reserved Unauthorized of this document is strictly prohibited of Origin USA

Related Files