Notifier NCM-W, NCM-F Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name notifier-ncm-w-ncm-f-data-sheet-4371256890.pdf
Type PDF
Size 924.78 KB
Downloads

Text Preview

NCM W NCM F ONYX Series Network Communications Modules Network Communications Module NCM provides NOTIFIER Fire Alarm Control Panels and NCA and NCA 2 Network Annunciators with a means to connect to NOTI types of NCM are available NCM W for connecting nodes with wire and NCM F for connecting nodes with fiber optic Do not mix NCM and High Speed HS NCM on the same system Features Supports twisted pair wire medium NFPA Style 4 Class B operation or NFPA Style 7 Class A operation Two programmable data thresholds Transformer coupling provides electrical isolation between nodes Pluggable terminal wiring with strain relief Pluggable service connector feeds signal directly through in the that power must be removed from a node 312.5 Kbaud transmission rate Data is regenerated at each node Two network ports to allow simultaneous connection to fire alarm panel and to programming computer Enables software and database upload download over Repeaters are available to increase signal Repeaters may be utilized to switch media type Up to 3,000 feet 914.4 m between nodes in a point to point actual distance varies with wire quality Interconnections When wiring consecutive NCM W wiring may enter or exit at Port A or Port B NCM W port wiring is not polarity sensitive use of Port A or Port B is An NCM W may be connected to any of the following MIB W MIB WF NAM 232W NCM W in another panel network connection RPT W RPT WF Switch Functions The NCM W provides two sets of to simplify network setup Enable ground fault detection setting switch SW103 Channel A switch SW101 Chan B Activate on board end of line resistors by setting SW100 Channel A switch 102 Channel B NOTE Cor configuration is dependent on network design refer to the Network manual further information and diagrams refer to the NCM Installation 51533 Features Supports fiber optic medium NFPA Style 4 Class B or Style 7 Class A operation Data is immune to all environmental noise Optical isolation prevents ground loops NOTI Network fiber optic medium Fiber type 62.5 125 micrometers multimode or 50 125 microm Maximum attenuation is 8 dB with 62.5 125 fiber and 4.2 dB multimode 50 125 fiber Wavelength 1 820 nanometers use standard 850 nm fiber Connectors ST style 312.5 Kbaud transmission rate Data is regenerated at each node Two network ports to allow simultaneous connection to fire alarm panel and to programming computer Enables software and database upload download over Repeaters are available to increase signal Repeaters may be utilized to switch media type When wiring consecutive nodes fiber cable must exit one board on Transmit TX and the next node repeater on Receive RX The fiber optic pair TX from Port A of one node repeater may be connected to Port A or Port B of another node repeater An NCM F may connected to any of the following devices MIB F MIB WF another NCM F NCS Fnetwork connection RPT F Specifications and humidity ranges This system meets NFPA for operation at 0 to 49 32 to 120 and at a humidity noncondensing of 85 at 30 86 per and 93 2 at 32 2 89.6 1.1 per ULC the useful life of the system standby batteries and the components may be adversely affected by extreme tem ranges and humidity Therefore it is recommended that system and all peripherals be installed in an environment with nominal room temperature of 15 to 27 60 to 80 supply 24 VDC 110 mA WIRE AND FIBER ON THE SAME NETWORK some networks it may be necessary to mix twisted pair wire and cable There are two solutions any network an RPT WF may be used as an interface between and fiber a network that uses an AFP1010 or AM2020 a MIB WF may be as the interface between wire and fiber NCM W and NCM F can be installed in any standard chassis as the CHS 4L CHS M2 CHS M3 or CHS 4N see panel Additionally the NCM W can be door mounted on the dress panel on a single space blank plate BMP 1 for in an CAB 4 Series cabinet 3 5 19 Page 1 of 2 detail A B Listings and Approvals following listings and approvals apply to the NCM In some certain modules or applications may not be listed by certain agencies or listing may be in process Consult factory for listing status UL ULC Listed S635 CSFM 7165 0028 0224 NFS2 3030 7165 0028 0243 NFS NFS2 640 FM approved MEA approved FDNY COA 6306 COA 6212 Line Information Network Communications Module twisted pair wire interface Network Communications Module fiber optic cable interface LED Indicators HI green Illuminates to indicate the NCM W Port A is set for threshold NCM W only HI green Illuminates to indicate the NCM W Port B is set for threshold NCM W only A green Illuminates when the NCM is receiving data from on Port A B green Illuminates when the NCM is receiving data from on Port B yellow Illuminates when the NCM has not received valid from NOTI on Port A for at least 16 seconds yellow Illuminates when the NCM has not received valid from NOTI on Port B for at least 16 seconds is in progress green is in progress yellow Illuminates when the microcontroller fails green Illuminates when 5 VDC is available when a on when NCM Fault and detail signal short A B Use Connection Ports NUP Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice is a trademark of Honeywell International Inc ONYX NOTIFIER are registered trademarks of Honeywell International ST is a registered trademark of AT T by Honeywell International Inc All rights reserved Unautho use of this document is strictly prohibited of Origin USA

Related Files