Notifier NFS-320SYS(E) Intelligent Addressable Fire Alarm System

File Preview
File Preview
Click below to download for free

Text Preview

cid 129 One isolated intelligent Signaling Line Circuit SLC Style 4 6 separate 200 event alarm only file Addressable Alarm System NFS 320SYS intelligent Fire Alarm Control Panel is part of ONYX Series of Fire Alarm Controls from NOTIFIER a stand alone small to large system or as a large network ONYX Series of products meet virtually every application modular design of the ONYX Series makes system plan easier The panel can be configured with just a few devices small building applications or networked with many devices protect a large campus or a high rise office block Simply add peripheral equipment to suit the application Wireless protection can be added with the SWIFT wireless gateway devices Unless called out with a version specific at the end of part number refers to models NFS 320SYS NFS 320SYSE similarly refers to models and CPU 320SYSE Certified for seismic applications when used with the appro seismic mounting kit Approved for Marine applications when used with listed com equipment See DN 60688 7 Up to 159 detectors and 159 modules per SLC 318 devices Detectors can be any mix of ion photo thermal or multi wireless detectors are available for use with the Modules include addressable pull stations normally open devices two wire smoke detectors notification or wireless modules are available for use with the Optional FWSG Wireless SWIFT Gateway supports wireless devices Standard 80 character display Network options High speed network for up to 200 nodes NFS2 3030 NFS 320 C NFS 320SYS NCA 2 DVC EM NFS 3030 NFS 640 and NCA Standard network for up to 103 nodes NFS2 3030 NFS2 NFS 320 C NFS 320SYS NCA 2 DVC EM ONYX NCS NFS 3030 NFS 640 NCA AFP 200 AFP AFP 1010 and AM2020 Up to 54 nodes when is used in network paging 6.0 A switch mode power supply with four Class A B built in Appliance Circuits NAC Selectable System Wheelock or Gentex strobe synchronization Built in Alarm Trouble and Supervisory relays VeriFire Tools online offline program option Sort Mainte Reports by compensation value dirty detector peak value or address Autoprogramming and Walk Test reports Multiple central station communication options Standard UDACT Internet Internet GSM Fire Alarm Control Panels EIA 485 annunciators including custom graphics Printer interface 80 column and 40 column printers History file with 800 event capacity in nonvolatile memory Alarm Verification selection per point with automatic counter Positive Alarm Sequence PAS Presignal Silence inhibit and Auto Silence timer options March time temporal California two stage coding strobe syn Field programmable on panel or on PC with VeriFire Tools check compare simulate Full QWERTY keypad Charger for up to 200 hours of standby power Non alarm points for lower priority functions Remote ACK Signal Silence System Reset Drill via monitor Automatic time control functions with holiday exceptions Surface Mount Technology SMT electronics Extensive built in transient protection Powerful Boolean logic equations INTELLIGENT FEATURES Polls up to 318 devices in less than two seconds Activates up to 159 outputs in less than five seconds Multicolor LEDs blink device address during Walk Test Fully digital high precision protocol U S Patent 5,539,389 Manual sensitivity adjustment up to nine levels Pre alarm ONYX intelligent sensing up to nine levels Day Night automatic sensitivity adjustment Sensitivity windows Ion 0.5 to 2.5 foot obscuration Photo 0.5 to 2.35 foot obscuration Laser VIEW 0.02 to 2.0 foot obscuration Acclimate Plus 0.5 to 4.0 foot obscuration IntelliQuad 1.0 to 4.0 foot obscuration IntelliQuad PLUS 1.0 to 4.0 foot obscuration 3 8 17 Page 1 of 6 80 character remote annunciators up to 32 Drift compensation U S Patent 5,764,142 INTELLIQUAD MULTI CRITERIA DETECTOR Detects all four major elements of a fire smoke heat CO flame Automatic drift compensation of smoke sensor and CO cell High nuisance alarm immunity FAAST DETECTORS FSA 5000 FSA 8000 AND FSA 20000P Connects directly to the SLC loop of compatible ONYX series Provides five event thresholds that can be individually pro with descriptive labels for control by event pro uses five detector addresses Uses patented particle separator and field replaceable filter remove contaminants Advanced algorithms reject common nuisance conditions FSA 5000 covers 5,000 square feet through one pipe FSA 8000 covers 8,000 square feet through one pipe FSA 20000 covers 28,800 square feet through one to four FSA 20000P covers 28,800 square feet through one to four pipes Supports addressable pipes to pinpoint of alarm events INTELLIQUAD PLUS MULTI CRITERIA FIRE CO DETECTOR Detects all four major elements of a fire Separate signal for life safety CO detection Optional addressable sounder base for Temp 3 fire or tone Automatic drift compensation of smoke sensor and CO cell Intelligent Loop 1 I O Modules Contact Degraded mode in the unlikely event that the CPU microprocessor fails FlashScan detectors revert to operation and can activate the CPU 320SYS NAC and alarm relay Each of the four built in panel circuits a Disable Enable switch for this feature Multi detector algorithm involves nearby detectors in alarm U S Patent 5,627,515 Automatic detector sensitivity testing Maintenance alert two levels Self optimizing pre alarm VERY INTELLIGENT EARLY WARNING DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate smoke and non smoke signals U S Patent Addressable operation pinpoints the fire location Early warning performance comparable to the best aspiration at a fraction of the lifetime cost ACCLIMATE PLUS INTELLIGENT MULTI SENSOR Detector automatically adjusts sensitivity levels without oper intervention or programming Sensitivity increases with Microprocessor based technology combination photo and Low temperature warning signal at 40 5 4.44 technology to 32 remote displays IntelliQuad Acclimate PLUS FSL 751 FlashScan VIEW FSP 851 Photo Ion Thermal display annunciator control points Control Annunciator Graphics 318 point UDACT phone to Series Printer cabinet size shown 2 of 6 DN 60637 L cid 129 3 8 17 High nuisance alarm immunity WIRELESS Self healing mesh wireless protocol Each SWIFT Gateway supports up to 50 devices 1 wireless and up to 49 SWIFT devices Up to 4 wireless gateways can be installed with overlapping coverage FEATURES Ten independent hazards Sophisticated cross zone three options Delay timer and Discharge timers adjustable Abort four options Low pressure CO2 listed AND TELEPHONE FEATURES Telephone applications require NFC FFT with FirstCommand Series See DN 60772 OFFLINE SWITCHING A POWER SUPPLY 6.0 A IN ALARM

Related Files