Notifier NFS2-640

File Preview
File Preview
Click below to download for free

File Data

Name notifier-nfs2-640-4932608157.pdf
Type PDF
Size 1.18 MB
Downloads

Text Preview

NFS2 640 Addressable Alarm System NFS2 640 intelligent Fire Alarm Control Panel is part of the Series of Fire Alarm Controls from NOTIFIER a stand alone small to large system or as a large network ONYX Series of products meets virtually every application with modularity and for ease of system planning the can be configured with just a few devices for small applications or for a large campus or high rise applica Simply add additional peripheral equipment to suit the Unless called out with a version specific at the end of part number refers to models NFS2 640 and similarly refers to models CPU2 640 CPU2 640E Listed to UL Standard 864 9th edition One expandable to two isolated intelligent Signaling Line SLC Style 4 6 or 7 Up to 159 detectors any mix of ion photo thermal or multi and 159 modules Addressable pull stations nor open contact devices two wire smoke notification or per SLC 318 devices per loop 636 per FACP or net node Standard 80 character display 640 character large display display less a node on a network Network option 103 nodes supported AFP 200 AFP 300 NFS 320 NFS 640 NFS2 640 AFP1010 AM2020 NFS2 3030 NCA NCA 2 Network Annunciator NCS Network Control Station or ONYXWorks Control Station using wire or fiber optic connec 6.0 amp switch mode power supply with four Class A B built Notification Appliance Circuits NAC Selectable System Wheelock or Gentex strobe synchronization Built in Alarm Trouble Security and Supervisory relays VeriFire Tools online or offline programming utility Upload save store check compare and simulate panel Upgrade panel firmware Autoprogramming and Walk Test reports Optional universal 636 point DACT 80 character remote annunciators up to 32 EIA 485 annunciators including custom graphics Printer interface 80 column and 40 column printers History file with 800 event capacity in nonvolatile memory separate 200 event alarm only file Alarm Verification selection per point with tally Autoprogramming and Walk Test reports Presignal Positive Alarm Sequence PAS Silence inhibit and Auto Silence timer options March time temporal California two stage coding strobe syn Field programmable on panel or on PC with VeriFire Tools check compare simulate Full QWERTY keypad Battery charger supports 18 200 amp hour batteries Non alarm points for lower priority functions cid 129 A 13 Fire Alarm Control Panels Remote ACK Signal Silence System Reset Drill via monitor Automatic time control functions with holiday exceptions Surface Mount Technology SMT electronics Extensive built in transient protection Powerful Boolean logic equations 640 CHARACTER DISPLAY FEATURES Backlit 640 character display Supports SCS Series smoke control system in both HVAC or modes not UL Listed for FSCS Printer and CRT EIA 232 ports EIA 485 annunciator and terminal mode ports Alarm Trouble Supervisory and Security relays INTELLIGENT FEATURES Poll 318 devices in less than two seconds Activate up to 159 outputs in less than five seconds Multicolor LEDs blink device address during Walk Test Fully digital high precision protocol U S Patent 5,539,389 Manual sensitivity adjustment nine levels Pre alarm ONYX intelligent sensing nine levels Day Night automatic sensitivity adjustment Sensitivity windows Ion 0.5 to 2.5 foot obscuration Photo 0.5 to 2.35 foot obscuration Laser VIEW 0.02 to 2.0 foot obscuration Acclimate Plus 0.5 to 4.0 foot obscuration HARSH 0.5 to 2.35 foot obscuration IntelliQuad 1.0 to 4.0 foot obscuration Drift compensation U S Patent 5,764,142 Degraded mode in the unlikely event that the CPU2 640 fails FlashScan detectors revert to degraded and can activate the CPU2 640 NAC circuits and relay Each of the four built in panel circuits includes a switch for this feature Multi detector algorithm involves nearby detectors in alarm U S Patent 5,627,515 10 17 08 Page 1 of 10 Automatic detector sensitivity testing NFPA 72 compliant Maintenance alert two levels Self optimizing pre alarm INTELLIQUAD MULTI CRITERIA DETECTOR Detects all four major elements of a fire smoke heat CO flame Automatic drift compensation of smoke sensor and CO cell High nuisance alarm immunity Six sensitivity levels VERY INTELLIGENT EARLY WARNING DETECTION TECHNOLOGY Revolutionary spot laser design Advanced ONYX intelligent sensing algorithms differentiate smoke and non smoke signals U S Patent Addressable operation pinpoints the fire location No moving parts to fail or filters to change Early warning performance comparable to the best aspiration at a fraction of the lifetime cost PLUS INTELLIGENT MULTI SENSOR Detector automatically adjusts sensitivity levels without oper intervention or programming Sensitivity increases with Microprocessor based technology combination photo and technology FlashScan or classic mode compatible Low temperature warning signal at 40 5 4.44 HOSTILE AREA SMOKE HEAD Provides early warning of smoke detection in environment traditional smoke detectors are not practical The detector filters remove particulates down to 30 microns size fan draws air into photo chamber while airborne parti and water mist are removed Requires auxiliary 24 VDC from system or remote power FEATURES Ten independent hazards Sophisticated cross zone three options Delay timer and Discharge timers adjustable Abort four options Low pressure CO2 listed AND TELEPHONE FEATURES Up to eight channels of digital audio 50 and 75 watt digital amplifiers DAA series Solid state digital message generation Firefighter telephone option 30 to 120 watt high efficiency amplifiers AA Series Backup tone generator and amplifier option Multichannel voice transponder XPIQ OFFLINE SWITCHING AMP POWER SUPPLY 6.0 A IN ALARM 120 VAC NFS2 640 240 VAC NFS2 640E Displays battery current voltage on panel with display 2 of 10 dn 7111 b cid 129 10 17 08 Exclusive New Detector Protocol the heart of the NFS2 640 is a set of detection devices and protocol FlashScan U S Patent 5,539,389 Flash is an all digital protocol that gives superior precision and noise immunity addition to providing quick identification of an active input this new protocol can also activate many output devices a fraction of the time required by competitive protocols This speed also allows the NFS2 640 to have the largest device loop capacity in the industry 318 points yet every input output device is sampled in less than two seconds The FlashScan detectors have bicolor LEDs can be coded to provide diagnostic information such as address during Walk Test Intelligent Sensing sensing is a set of software algorithms that provides NFS2 640 with industry leading smoke detection capability complex algorithms require many calculations on each of each detector and are made possible by the high microcomputer used by the NFS2 640 Compensation and Smoothing Drift compensation the detector to retain its original ability to detect actual and resist false alarms even as dirt accumulates It maintenance requirements by allowing the system to perform

Related Files