Notifier NION-48M-Installation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-nion-48m-installation-3528740169.pdf |
---|---|
Type | |
Size | 1.26 MB |
Downloads |
Text Preview
NION 48M Installation Document document covers the procedures and specifications for installing the above listed unit and when information regarding configuration on the monitored device For more detailed configura and operation information refer to Network Installation Manual Echelon Local Area Server Manual BCI 3 Manual as appropriate of the NION 48M in function to the NION 2C8M the NION 48M is a discrete input interface used on the network All of system components are based on LonWorks cid 153 Local Operating Network technologies The NION 48M a gateway to the network for discrete monitored devices equipment and control panels that have dry It allows discrete devices to operate on the same network as equipment with an EIA 232 output NION 48M connects a LonWorks cid 153 FT 10 or FO 10 network with discrete monitored devices and conven control panels It provides a single two way communication channel for discrete inputs NIONs are specific the type of network to which they connect FT 10 or FO 10 The transceiver type must be specified and ordered when ordering the NION NION 48M can be powered by any 24VDC power limited source with battery backup which is UL listed for with fire protective signaling units however this unit does include an MPS24B power supply Power must be or placed within 20 ft of the NION with connections run in conduit NION 48M mounts in an enclosure NIS CAB 3 with conduit knockouts It cannot be rack mounted Power LEDs Backup Used Pin LEDs Pin LEDs Board 1 Cable Board Layout 50856 NION 48M Installation Rev A 9 30 98 Program for Inputs 1 20 and 25 44 Jumpers Inputs 21 24 and 45 48 Legend for 21 24 and 45 48 Jumpers for 1 20 and 25 44 Board 2 Ribbon Connectors Rev A 50956 ECN 98 112 NION 48M is designed to be wired to control panels and the network through plug in terminal strips NION 48M has the following features Accepts normally open or normally closed dry contact inputs in any combination from an included UL listed power supply the monitored UL listed control panels or an auxiliary power which is power limited supervised and UL listed for use with fire protective signaling units Alarm and trouble input LEDs Components service input LEDs can be configured as either two state unsupervised or four state supervised with EOL resistors coupled network connection using SMX style transceivers configurable from the workstation plug in utility protection to 2400V on all terminals wall mount enclosure NIS CAB 3 following illustration displays components included and required to install a 48M on the network All of these must be ordered separately Line cord not included Terminal Boards NION comes with two terminal which mount directly on the board with stand offs These provide terminal connections to inputs Mother Board NION motherboard contains all LEDs CPU configuration network interface firmware terminal board connections Assembly 4000TA 110VA trans and connector Network Transceiver SMX transceiver daughter board required for local network connec Three styles are available for topologies and media This board mounts on the mother with a header strip and two SMX transceiver must be separately CAB 3 NION 48M mounts in a cabinet with a Lexan plate X 9.25 W X 2.75 D Power Supply MPS24BRB supplies 2.0A of 24VDC power to operate the NION Up 200mA of resettable auxiliary power is available This supply contains an battery charger which can support to 17AH batteries cabinet provides space for 12AH To use 17AH capacity use the BB 17 battery box must be ordered separately 50856 NION 48M Installation Rev A 9 30 98 Requirements NION 48M can be installed in the following environmental conditions range of 0 to 49 32 cid 176 F 120 cid 176 F humidity non condensing at 30 86 cid 176 F NION 48M comes standard with a wall mount enclosure the NIS CAB3 This enclosure has a locking door mounting hardware for the 48M assembly motherboard terminal boards and network transceiver power supply transformer and batteries the enclosure to its wall position Use the provided key to unlock the enclosure cover Remove the enclosure cover Mount the enclosure to the wall Refer to the enclosure mounting hole layout below Mount the MPS24B power supply and transformer to the stand offs in the back of the cabinet using the hardware Mount the 48M motherboard to the mounting rails in the same manner Location NION 48M is designed to be installed on a wall within 20 feet of the monitored equipment in the same room type of hardware used is at the discretion of the installer but must be in accordance with local code require Device Addressing addressing at the workstation uses the following convention IN1 through IN48 50856 NION 48M Installation Rev A 9 30 98 Power Requirements NION 48M is powered by the included MPS24BRB power supply The MPS24BRB uses 110VAC 1.8A max power and provides 2.0A of 24VDC power and battery backup in accordance with local code requirements MPS24BRB contains a built in battery charging circuit capable of supporting 6.5 to 17AH 24VDC batteries the NION can be powered by any power limited 24 VDC source which is UL or ULC listed as appro for your area for use with fire protective signaling units For replacement part orders specify MPS24BRB for Board connections from the MPS24BRB to the NION must be as follows on the 48M motherboard to pins 3 and 4 of TB2 on the MPS24BRB on both boards are labelled for proper connections Closed Contacts open when the power supply enters a condition JP1 to make auxiliary non resettable not cut Used disables battery Power Reset Power 6.5 to 17AH Supervised and Fast charge 0.75 amps trickle charge 20mA typical NION Power is power limited RMS regulated 2.0 amps max 24VDC Power max Power limited regulated and resettable Power Supply Ground to chassis with a cable assembly 71073 Neutral Earth Service Ground Power 1.8 amps max Always remove power from the NION before making any changes to switch settings removing or installing option modules SMX network modules and software upgrade chips damage may result 50856 NION 48M Installation Rev A 9 30 98 Configuration can be configured for two state unsupervised or four state supervised operation In addition 8 inputs 21 45 48 can be configured to monitor switched voltage inputs These configuration settings are made with on the 48M motherboard These jumpers are grouped in an area beneath the terminal boards 21 24 45 48 1 10 11 20 25 34 35 44 Configuration Jumpers Two state unsupervised inputs cannot be used for fire applications input jumpers are arranged left to right top to bottom Only Inputs 1 20 25 44 one through 20 and 25 through 44 can be configured as either two state or four state discrete inputs To the input type a single jumper is set for each input The diagram above displays the location of these and the following table describes which jumper applies each input