Notifier NMM-100-10(A) Ten-Input Monitor Module

File Preview
File Preview
Click below to download for free

File Data

Name notifier-nmm-100-10-a-ten-input-monitor-module-4563271890.pdf
Type PDF
Size 1.15 MB
Downloads

Text Preview

NMM 100 10 A Monitor Module NMM 100 10 ten input monitor module is an interface a FireWarden series control panel and normally contact devices in intelligent alarm systems such as stations security contacts or flow switches first address on the NMM 100 10 is set from 01 to 90 the remaining modules are automatically assigned to the nine higher addresses Provisions are included for dis a maximum of two unused addresses supervised state normal open or short of the moni device is sent back to the panel A common SLC input used for all modules and the initiating device loops share a supervisory supply and ground otherwise each operates independently from the others NMM 100 10 module has panel controlled green LED The panel can cause the LEDs to blink latch on latch off Unless otherwise specified the term NMM 100 10 is used this data sheet to refer to both the NMM 100 10 and the NMM ULC listed version Listed to UL Standard 864 9th edition Ten addressable Class B or five addressable Class A initi device circuits Removable 12 AWG 3.31 mm to 18 AWG 0.821 mm terminal blocks Status indicators for each point Unused addresses may be disabled Rotary address switches Class A or Class B operation Flexible mounting options Mounting hardware included current 3.5 mA SLC current draw with all used if some addresses are disabled the current decreases current 55 mA assumes all ten LEDs solid ON range 32 to 120 0 to 49 for UL to 55 for EN54 applications 10 to 85 noncondensing for UL applications to 93 noncondensing for EN54 applications 6.8 172.72 mm high x 5.8 147.32 mm x 1.25 31.75 mm deep weight 0.76 lb 0.345 kg including packaging A1 351 Devices options CHS 6 chassis Up to 6 modules BB 25 cabinet Up to 6 modules BB XP cabinet One or two modules gauge 12 AWG 3.31 mm to 18 AWG 0.821 mm circuits must employ type FPL FPLR or cable as required by Article 760 of the NEC supports both Class B and Class A wiring shunt for Class A operation SLC wiring resistance 40 or 50 ohms panel IDC wiring resistance 1500 ohms IDC voltage 10.2 VDC IDC current 240 Listings and Approvals listings and approvals below apply to the NMM 100 Monitor Module In some cases certain mod or applications may not be listed by certain approval or listing may be in process Consult factory for lat listing status UL Listed S635 ULC Listed S635 NMM 100 10A CSFM approved 7300 0028 256 FM approved 06 10 2009 Page 1 of 2 Line Information Ten input monitor module Same as above with ULC Listing Optional cabinet for one or two modules Dimen DOOR 9.234 23.454 cm wide 9.484 24.089 cm hinges x 12.218 31.0337 cm high x 0.672 cm deep BACKBOX 9.0 22.860 cm wide 9.25 cm including hinges x 12.0 30.480 cm high x 6.985 cm CHASSIS installed 7.150 18.161 cm overall x 7.312 18.5725 cm high interior overall x 5.4762 cm deep overall Optional cabinet for up to six modules mounted on chassis below Dimensions DOOR 24.0 60.96 wide x 12.632 32.0852 cm high x 1.25 3.175 cm hinged at bottom BACKBOX 24.0 60.96 cm wide x 31.877 cm high x 5.218 13.2537 cm deep Chassis mounts up to six modules in BB 25 NOTIFIER FireWarden and System Sensor are trademarks of Honeywell International Inc Microsoft and are registered trademarks of the Microsoft Corporation by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 6990 A 06 10 2009

Related Files