Notifier RA400Z & RA400ZA Remote Annunciators

File Preview
File Preview
Click below to download for free

File Data

Name notifier-ra400z-ra400za-remote-annunciators-1356728904.pdf
Type PDF
Size 625.50 KB
Downloads

Text Preview

RA400Z RA400ZA Annunciators System Sensor RA400Z and RA400ZA Canadian Annunciators are polarized devices designed for both and intelligent applications They have been using an active current regulator so that the maxi current required from the system is 7 mA when the input is within the specified voltage range Range CONVENTIONAL System 3.1 to 32 VDC NOT break tab Range INTELLIGENT System 18 to 32 VDC Break see caution note DO NOT break tab when using RA400Z or RA400ZA an intelligent four wire duct detector such as System Sen DH500ACDC or NOTIFIER DHX 501 Drain 7 mA maximum Range 10 to 60 14 to 140 For indoor applications only RA400Z RA400ZA is intended to be mounted to a single electrical outlet box The device must be operated within published specifications Wire the remote annunciator to the instructions supplied with the device being and in compliance with all codes Polarity of the wires must be observed and connected to the proper and see figure tab on the back of the remote annunciator must be broken for use with most System Sensor intelligent systems see and caution under Specifications After the tab is bro the input voltage for the RA400Z and RA400ZA is limited 18 volts minimum Limitations of Remote The remote annunciator will not work if the device it is to is not powered The remote annunciator its power from the device to which it is connected If any reason the device being monitored loses power the annunciator will not provide the intended visible sig The RA400Z is suitable for indoor applications only The remote annunciator may not be seen The model is suitable for direct viewing and is in compliance existing Underwriters Laboratories standards The must be sited in a location where it can be seen by intended parties The device must not be installed in sunlight or areas of high light intensity where the vis signal might be disregarded or not seen This device is designed to work specifically with cer NOTIFIER or System Sensor products Interconnec with devices other than those specified may result in operation Consult device manufacturer for The remote annunciator is not intended to be a visible signal cid 129 D 105 Control Systems Listings and Approvals listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL Listed S2522 ULC Listed S2522 RA400ZA MEA 427 91 E Vol II CSFM 7120 1653 111 FM Approved 07 15 08 Page 1 of 2 0 9 1ta b tif Sensor and NOTIFIER are registered trademarks of Honeywell Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 2 of 2 DN 6091 A cid 129 07 15 08

Related Files