System Sensor PDRP-1001-PDRP-1001A Preaction-Deluge System
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-pdrp-1001-pdrp-1001a-preaction-deluge-system-6014295783.pdf |
---|---|
Type | |
Size | 942.20 KB |
Downloads |
Text Preview
PDRP 1001 PDRP 1001A PDRP 1001E Preaction Deluge System Instructions Only the GREEN A C POWER LED is on All other are off KEY The key to open the panel can be found at this AUDIBLE DEVICES ARE SOUNDING has occurred if release LED is on timer has timed out if release LED is flashing AN ALARM Evacuate the protected area Notify the monitoring service and or the Fire Department immediately Tell them briefly what happened and what your current status is Fire Department Monitoring Service If the Fire Department is responding be prepared to provide directions to arriving firefighters TROUBLE ONLY is happening Notify the monitoring service and or Fire department if this panel is connected to either one and tell them Silence audible devices by unlocking and opening the panel and pressing the TONE SILENCE switch The SYSTEM TROUBLE LED will remain on Contact authorized service personnel immediately See Below NOT ALLOW TROUBLE CONDITIONS TO REMAIN LOGGED IN THE SYSTEM THE PROTECTION THE OFFERS HAS BEEN COMPROMISED OR ELIMINATED WHEN A TROUBLE CONDITION EXISTS return to normal after an alarm activation Fire Drill or otherwise Do not enter the protected area until safe to do so Clear all initiating devices Smoke detectors will not reset if there is still smoke in the area Reset the control panel PRESS the RESET switch failure or brownout Signalling Circuits can be activated by pressing the ACTIVATE switch May want to disconnect municipal box by sliding switch located on 4XTM module to DOWN position AC power drops too low or fails the POWER ON LED will go out SYSTEM TROUBLE LED will turn on and the panel buzzer and other audible trouble devices will sound Contact authorized personel immediately See below Silencing Signalling Circuits may be silenced by pressing the SILENCE switch The ALARM SILENCED LED will on Subsequent alarms will reactivate circuits Press the switch to clear the silenced condition A Pittway Company the event of trouble the local System Service test the lamps Number AND POST TO THE and hold the RESET switch and check all the LED one should be on as long as the switch is held on more information refer to the PDRP 1001 PDRP 1001A manual It is kept in the following location 50736 Revision C ECN 99 166 2 3 99 P N 50736 C