VESDA-E VEA Series Detectors

File Preview
File Preview
Click below to download for free

File Data

Name vesda-e-vea-series-detectors-3645091728.pdf
Type PDF
Size 893.93 KB
Downloads

Text Preview

VESDA E VEA VESDA E VEA series of detectors combine VESDA reliability and warning smoke detection with pinpoint addressability and a variety of options that truly surpass traditional spot detectors They use air sampling points and multi channel microbore air sampling with alarm sensitivity settings for the sampling points As a multi channel system the VEA detector is able to divide a protected space sampling locations enabling the localization of potential sources of for faster incident response The detectors are suitable for protection areas where pinpoint location of fire events is essential thus providing fire detection solutions for healthcare offices education retail prisons electrical cabinets A wide range of features provide flexibility field enhanced connectivity and reduced total cost of ownership Commissioning and Maintenance VEA detector features a robust IP40 rated enclosure and is equipped a powerful pump that provides up to 100 m 330 ft microbore tube It is fully supported by the Xtralis VSC software which facilitates ease system commissioning and maintenance During commissioning the process establishes the flow performance parameters Local test ports are used during servicing to verify that the system is fully Field replaceable filter smoke sensor module pump and rotary components result in less down time and ease of maintenance LCD display VEU 040 A10 detector features a 3.5 colour LCD display which provides range of status information including alarm and fault conditions as well smoke level Screens for each type of information are available using a navigation system detectors and devices communicate on VESDAnet which provides robust bi directional communication network allowing continued redundant even during single point wiring failures VESDAnet enables primary centralized configuration control maintenance and monitoring and WiFi connectivity detectors offer Ethernet and WiFi connectivity as standard The detector can be added to a corporate network allowing enabled tablet devices and laptops installed with Xtralis configuration to connect wirelessly to the detector via the network VEA 040 A10 Pinpoint addressability with superior compared to spot detectors 40 addressable microbore tubes with sampling points Assured detection with end to end system monitoring business operation with testing and maintenance Single sampling point or single tube detection Automatic sampling point presence and breakage detection Automatic sampling point cleaning Three sensitivity settings for the sampling ft Variable length capillary tubes up to 100 m Laser based absolute smoke detection Dual stage filtering and clean air barrier for protection Reliable linear pump technology LEDs for alarm and fault signalling 3.5 colour touch screen for status review Seven programmable relays Two GPIs monitored and unmonitored Xtralis VSC and VSM4 PC software application for system monitoring mobile devices 40 enclosure not UL tested Easy mounting with steel support bracket Field replaceable filter smoke sensor pump and rotary valve VESDAnet networking Ethernet 100 base T WiFi 802.11 b g n Local host mode USB port Easy cable termination access Event Log 20,000 events Approvals UL ULC Other major agency approvals pending approvals listings and regulatory compliance vary between models Refer to www xtralis com for the latest product approvals VEA Voltage Consumption 24VDC to 30 VDC current scan mode WHD Conditions Tube Size Tube Length Monitoring Rating Access Termination Alarm Thresholds the Sampling Hole Interfaces Features VEA 040 A10 W W W W Average for initial 5 seconds of scanning Vacuum Pump mm x 336 mm x 135.5 mm 13.9in x 13.2in x 5.33in 9.9 kg 21.8 lbs 10 kg 22.2 lbs 0 to 39 32 to 102 Air 0 to 50 32 to 122 to 0 to 49 32 to 120 10 to 95 RH non condensing 6 mm ID 4 mm 4 mm ID 2.5 mm to 100m 330 ft sampling point and single tube blockage and breakage programmable relays latch or non latch states rated 2 A 30 VDC Resistive x 25 mm 1 cable entries Terminal blocks 0.2 sq mm 24 14 AWG and Action two pre alarm levels 0.006 ft 16 m 4.88 ft Type 2 Ethernet RJ45 WiFi 802.11 b g n log Up to 20,000 events stored in FIFO format smoke user actions alarms and faults with time and date stamp m 0.5 ft m 1.3 ft m 2.5 ft Product UL Listed between 0 to 39 32 to 102 Information VEA 40 Aspirating Smoke with LEDs VEA 40 Aspirating Smoke with 3.5 Display VEA 20 Expansion StaX VEA 40 Expansion StaX VEA 40 Relay Local StaX Point for 6mm Tube Point for 6mm Tube 22 pack VSP 980 22 Point for 6mm Tube 44 pack VSP 980 44 Point for 4mm Tube Point for 4mm Tube 22 pack VSP 981 22 Point for 4mm Tube 44 pack VSP 981 44 Parts VEA 40 Mounting Bracket VEA 40 Smoke Sensor Module VEA Filter VEA Pump VEA Rotary Valve VEA 040 A00 Fascia with LEDs VEA 040 A10 Fascia with 3.5 Display VSP 976 and Europe 44 1442 242 330 D A CH 49 431 23284 1 The Americas 1 781 740 2223 East 962 6 588 5622 Asia 86 21 5240 0077 Australia and New Zealand 61 3 9936 7000 contents of this document are provided on an is basis No representation or warranty either express or implied is made as to the accuracy or reliability of the contents of this document The manufacturer reserves the right to change designs or specifications obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any warranties of merchantability and fitness for a particular purpose are expressly excluded the Xtralis logo The Sooner You Know VESDA E VESDA ICAM ECO OSID HeiTel ADPRO IntrusionTrace LoiterTrace ClientTrace XOa XOh iTrace iCommand iRespond iCommission iPIR and FMST are trademarks and or registered trademarks of Xtralis and or its in the United States and or other countries Other brand names mentioned herein are for identification purposes only and may be trademarks their respective holder s Your use of this document does not constitute or create a licence or any other right to use the name and or trademark and label document is subject to copyright owned by Xtralis You agree not to copy communicate to the public adapt distribute transfer sell modify or any contents of this document without the express prior written consent of Xtralis no 22210 09 30359 VEA 040 A10 it works VEA detector draws a combined sample from a network of flexible tubing from all points in the protected area filters and analyzes the sample laser detection chambers in the sensor module When smoke are detected and the smoke reaches set alarm thresholds system will raise appropriate conditions After a Fire 1 alarm raised the system will sequentially the sampling locations via the valve to identify one or more locations with the fire alarm To assist in investigation of the of a fire if the system is in Pre the user can initiate a smoke of all sampling locations VEA uses a vacuum pump provides superior detection for long tube lengths The monitors the airflow within installation allowing detection of or blockages of individual points and sampling tubes faults indicated on the display and the monitoring equipment and fire location can be via Relays

Related Files