VESDA-E VES Series Aspirating Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name vesda-e-ves-series-aspirating-smoke-detector-0179342568.pdf
Type PDF
Size 1.23 MB
Downloads

Text Preview

VES A00 P Sector addressability for up to four sectors Adaptive scan threshold Flair detection technology delivers reliable very warning in a wide range of environments minimal nuisance alarms Multi stage filtration and optical protection with air barriers ensures lifetime detection Four configurable alarm levels per sector a wide sensitivity range deliver optimum for the widest range of applications LCD display provides instant status for immediate response Flow fault thresholds per port accommodate airflow conditions Smart on board filter retains dust count and filter life for predictable maintenance Extensive event log 20,000 events for event and system diagnostics AutoLearn smoke and flow for reliable and commissioning Backward compatible with VLS and VESDAnet Ethernet for connectivity with Xtralis software configuration secondary monitoring and Secondary monitoring and maintenance via USB for PC configuration and firmware using a memory stick Two programmable GPIs 1 monitored for remote control Field replaceable sub assemblies enable service and maximum uptime Approvals UL ULC approvals listings and regulatory compliance vary between models Refer to www xtralis com for the latest product approvals VES VESDA E VES is similar to the flagship VESDA E VEP aspirating smoke detector but also a valve mechanism in the inlet manifold and software to control the airflow from the four pipes This configuration enables a single zone to be divided into four separate sectors example distinguishing between separate aisles within a data room The VES enables the to locate the source of smoke by identifying the first sector to reach the Alert level The then continues to sample from all sectors to monitor fire growth and will report separate levels for each sector The VES provides four individually configurable alarm levels Action Fire 1 and Fire 2 for each sector allowing optimum protection in a wide range of Built on the Flair detection technology and years of application experience VES achieve consistent performance over their lifetime via absolute calibration In addition VES delivers a range of revolutionary features that provide user value it Works VES draws air from all sectors in use If the smoke level reaches the Adaptive Scan the VES quickly scans each sector to identify which sector is carrying smoke The sector to reach the Alert level is designated as the First Alarm Sector FAS and this sector is to the user If two or more sectors reach the Alert level then the sector with the highest concentration is designated as the First Alarm Sector FAS Once Fast Scan is completed the FAS identified the VES continues to closely monitor all four sectors to track fire growth maintain full protection of the area Detection Technology is the revolutionary detection chamber that forms the core of the VESDA E VES providing stability and increased longevity Direct imaging of the sampled particles using a CMOS combined with multiple photo diodes allows better detection and fewer nuisance alarms VES Display VES display Home page has a bar graph to indicate the smoke level and adaptive scan Fault icons are also included to indicate various fault conditions When the adaptive threshold is exceeded the VES display automatically transitions to the Sector status page indicate the smoke level and alarm level per sector If alarms are configured as latched then indication per sector will be retained until Reset is applied The VES display can only return the Home page under user control Commissioning and Operation VES is equipped with a powerful aspirator that enables the use of 560 m 1,837 ft total pipe length Out of box operation is made possible with AutoConfig which allows airflow and AutoLearn Smoke and Flow to be initiated from within the detector VES is fully by Xtralis VSC and ASPIRE software applications which facilitate ease of pipe network system commissioning and maintenance devices communicate on VESDAnet which provides a robust bidirectional communication allowing continued redundant operation even during single point wiring failures enables primary reporting centralized configuration control maintenance and and WiFi connectivity detectors offer Ethernet and WiFi connectivity as standard features The detector can added to a corporate network allowing WiFi enabled tablet devices and PC installed with monitoring and configuration software to connect wirelessly to the detector via the network Compatibility VES is compatible with existing VESDA installations The detector occupies the same footprint pipe conduit and electrical connector positioning as VESDA VLS VES is also with existing VESDAnet installations allowing monitoring of both VESDA E and legacy via the latest iVESDA application VES voltage consumption 24 VDC Setting Quiescent In Alarm WHD conditions Coverage airflow per pipe Length Linear Length Branched lengths depending on of pipes in use of holes A B C design tool rating access termination Range Range setting range features VDC 24 V Nominal W W W 15.8 W W 10.4 W 11.6 W 16.6 W kg 9.7 lb W W W W mm x 225 mm x 135 mm 13.8 in x 8.9 in x 5.3 in kg 9.5 lb 0 to 39 32 to 102 to EN54 20 10 to 55 14 to 131 Air 20 to 60 4 to 140 5 to 95 RH non condensing m2 21,520 sq ft l m m 919 ft m 1,837 ft Pipe m 328 ft Pipe m 262 ft Pipe m 230 ft External diameter 25 mm or 1.05 in 3 4 in IPS External diameter 25 mm or 1.05 in 3 4 in IPS via programmable relays latching or non latching states rated 2 A 30 VDC Resistive x 26 mm 1.02 in cable entries Terminal blocks 0.2 sq mm 24 AWG to 32 obs m 0.0003 to 10 obs ft to 20 obs m 0.0016 to 6.25 obs ft 0.005 to 2.0 obs m 0.0016 to 0.625 obs ft 0.005 to 2.0 obs m 0.0016 to 0.625 obs ft 0.010 to 2.0 obs m 0.0031 to 0.625 obs ft 0.020 to 20.0 obs m 0.0063 to 6.25 obs ft log Up to 20,000 events level and alarm threshold levels user actions alarms faults with time and date stamp Detector learns Alarm Thresholds and Flow Fault by monitoring the environment Product UL listed for use from 0 to 38 32 to 100 Sampled Air temperature shall reach Detector Ambient temperature upon entry into Detector Refer to Xtralis Guides Application Notes for sampled air pre conditioning Subject to agency confirmation Information Parts VES with LEDs Plastic Enclosure VES with 3.5 Display Plastic Enclosure VES with LEDs Plastic Enclosure NF VES with 3.5 Display Plastic Enclosure NF VES Demo Kit Compliance refer to the Product Guide for details regarding design installation and commissioning VES Scanner Manifold Spare Mounting Bracket Exhaust adaptor US Filter Filter 20 Pieces Aspirator Smoke Detection Chamber MK3 Sampling Module VES A00 P Front Cover Plastic LEDs VES A10 P Front Cover Plastic 3.5 Display VSP 969 S and Europe 44 1442 242 330 The Americas 1 800 229 4434 East 962 6 588 5622 Asia 86 21 5240 0077 Australia and New Zealand 61 3 9936 7000 contents of this document are provided on an is basis No representation or warranty either express or implied is made as to the completeness or reliability of the contents of this document The manufacturer reserves the right to change designs or specifications without obligation without further notice Except as otherwise provided all warranties express or implied including without limitation any implied warranties of and fitness for a particular purpose are expressly excluded the Xtralis logo The Sooner You Know

Related Files