Potter AVSM Series Gangable Synchronization Control Module

File Preview
File Preview
Click below to download for free

Text Preview

Features Operates with S 24 HS 24 CS and CHS series horn and strobe with the use of only two wires No limit to the number of modules that can be synchronized Module is rated for 3 amps continuous current and 5 amps surge inrush current to 1Hz flash rate Operates 1 class circuit or 2 class circuits at 3 amps per Dual synchronization module ONLY when using 2 class A green LED status indicator to signal operation of module Option to silence the horn while strobes continue to flash when temporal 3 mode AVSM WILL NOT operate the ST HS Series Module Dimensions 3.85 9.78 cm H x 3.82 9.70 cm W x 3.35 cm D Dimensions 5.57 14.15 cm H x 4.55 11.56 cm W x 6.07 cm D the control module as shown in the following the control module will control the power to the signaling to produce synchronized operation AVSM module is shipped with a back box and cover A green LED status indicator will flash once every four seconds zone 1 is operational The LED will flash twice every four seconds if 1 and 2 are operational Strobes should not be used on coded or signaling circuits 1 OF 4 includes a 5 year warranty Series Product Draw VDC VDC VDC UL Max1 VDC UL Max1 mA mA mA mA current ratings are per UL average RMS method UL max current rating the maximum RMS current within the listed voltage range 16 33 VDC for VDC units 8 17 VDC for 12 VDC units For strobes the UL max current usually at the minimum listed voltage 16 VDC for 24 VDC units 8 VDC 12 VDC units For audibles the max current is usually at the amximum voltage For unfiltered FWR ratings see installation manual Potter AVSM synchronization control module is designed provide an easy way to synchronize multiple horns strobes and using only two wires in isntances where a synchronized is required When synchronizing multiple horns and horn strobes is the ability to silence the horn while allowing the strobes to to flash 8830064 REV A06 13PRINTED IN USAAVSMgANgABLE SYNCHRONIZATION CONTROL MODULEPotter Electric Signal Company LLC St Louis MO 63042 USA Cust Service 866 572 3005 Tech Support 866 956 0988 Canada 888 882 1833 www pottersignal comfirealarmresources com for Multiple CLASS B Circuit and Use of a Slave Module HORN SILENCE IS REMOVE JUMPER 1 2 3 4 OF LINE FOR ONLY B JUMPER ONLY IF HORN CIRCUIT IS USED JUMPER IN PLACE TO NEED FOR HORN ON AVSM SYNC OUT1 NEG1 OUT2 NEG2 SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H 2 OF LINE FOR B ONLY SYNC OUT1 NEG1 OUT2 NEG2 1 JUMPER IN PLACE ON UNITS UNLESS HORN SILENCE IS NEEDED SIGNAL S H SIGNAL S H OF LINE FOR B ONLY SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H OF LINE FOR B ONLY OF LINE FOR B ONLY 3 4 CROSSING LINES DO NOT INDICATE CONNECTIONS incoming positive power lead must be broken and each lead to be inserted into each of the top two terminals If two power are made to the signal one for the strobe and one for the only one of the runs must have its positive lead broken and under the two separate top terminals A barrier is provided prevent both leads from being placed under the same terminal AVSM module is listed per ANSI UL 1971 with a voltage of 8 33VDC FWR The AVSM module was tested to the voltage range s do not apply 80 and 110 of this range system operation It is for indoor use only with a temperature of 0 49 32 120 and a maximum humidity of humidity CAUTION The AVSM module is to be connected only to that provide continuously applied voltage Do not use this on coded or interrupted circuits in which the voltage is on and off A steady DC power is to be applied without any other protocol temporal 3 for synchronized strobes and horns this method you may Use only two wires to synchronize the temporal horn and strobe the ability to mute the horn Mute the horn only when the temporal horn option has been Use the Gentex synchronization protocol to provide and mute the horn if available for synchronized parallel unison horn strobe operation this method you may Use four wires where two wires are used to power and the strobe and two additional wires are used to and synchronize the horn either continuous horn and allow the FACP to control the or choose temporal horn and synchronize the horns with the synchronization protocol Use the Gentex synchronization protocol to provide and mute the horn if available 2 OF 4 8830064 REV A06 13PRINTED IN USAAVSMgANgABLE SYNCHRONIZATION CONTROL MODULEPotter Electric Signal Company LLC St Louis MO 63042 USA Cust Service 866 572 3005 Tech Support 866 956 0988 Canada 888 882 1833 www pottersignal comfirealarmresources com for Multiple CLASS B Circuit and Use of Multiple Slave Modules HORN SILENCE IS REMOVE JUMPER 1 2 3 4 5 6 7 8 SYNC OUT1 NEG1 OUT2 NEG2 OF LINE FOR ONLY B JUMPER ONLY IF HORN CIRCUIT IS USED JUMPER IN PLACE TO NEED FOR HORN ON AVSM SIGNAL S H SIGNAL S H 2 SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H SIGNAL SIGNAL S H S H SYNC OUT1 NEG1 OUT2 NEG2 OF LINE FOR B ONLY JUMPER IN PLACE ON UNITS UNLESS HORN SILENCE IS NEEDED 3 4 5 6 1 7 8 SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H SYNC OUT1 NEG1 OUT2 NEG2 SIGNAL S H SIGNAL S H OF LINE FOR B ONLY SIGNAL S H SIGNAL S H SIGNAL S H SIGNAL S H OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY OF LINE FOR B ONLY 3 OF 4 8830064 REV A06 13PRINTED IN USAAVSMgANgABLE SYNCHRONIZATION CONTROL MODULEPotter Electric Signal Company LLC St Louis MO 63042 USA Cust Service 866 572 3005 Tech Support 866 956 0988 Canada 888 882 1833 www pottersignal comfirealarmresources com for Multiple CLASS A Circuits and Use of a Slave Module OF LINE FOR A ONLY HORN SILENCE IS REMOVE JUMPER 1 OF LINE FOR A ONLY 2 OF LINE FOR

Related Files