Potter CPRTK Coupon Probe Replacement and Test Kit

File Preview
File Preview
Click below to download for free

File Data

Name potter-cprtk-coupon-probe-replacement-and-test-kit-4251607839.pdf
Type PDF
Size 1.35 MB
Downloads

Text Preview

CPRTK AND TeST KIT Pipe Systems Use Model CPrtK 4 older style ceiling mount not riser Mount rM style Turn Verify that the 1 2 drain valve is in the closed position remove 1 2 drain plug relieve system pressure from the coupon rack by opening the valve slowly Do not drain the coupon rack completely at time Use a container or bucket to catch the escaping water NOTe the water in the coupon rack will be pressurized to the pressure After the system pressure has been relieved the drain valve Fill the 120cc bottle by opening the drain valve slowly Close the drain valve Securely affix the cap to the bottle by making sure the cap screws tightly tape cap to bottle drain the remaining water from the coupon rack through the 1 2 valve into a container Close the 1 2 drain valve re install 1 2 plug into drain valve Locate the plastic document holder should be attached to the station Locate the completed coupon insertion envelope that corresponds with Outlet 1 remove the coupon holder from Outlet 1 Use a screwdriver loosen the plastic screw and nut See Fig 1 remove the from the coupon holder and place the coupon into the original coupon envelope repeat this process on 5 See Fig 3 DO NOT HANDLe COUPONS OR PRObeS WITH bARe connected to the corrosion monitoring probe remove the switches from the corrosion monitoring probes on outlet and 6 See Fig 3 if a union was used between the pressure and the corrosion monitoring probe you will not have to the wiring to the pressure switch remove corrosion probes from outlet 3 and 6 and discard remove the corrosion monitoring probe from the sealed using the latex gloves provided Carefully remove the threads and install the new probe in the same outlet the old was removed from remove the new corresponding coupon from the new coupon do nOt discard the envelope steel locations are for C1010 coupons locations are for CdA 360 coupons CPrtK 4 kit shown number 0090177 For dry Pipe and all riser rM Styles number 0090178 For older style ceiling mount riser Mount rM Styles read and follow the instructions and procedures provided this and referenced documents Failure to do so will inhibit the to provide accurate and complete test results not handle the coupons or probes with your bare hands Use the gloves provided CPrtK contains necessary components to remove replace and for analysis the test coupons and water sample from a Potter Monitoring Station for CPrtK 2 Kit Includes two C1010 Mild Steel Corrosion Coupons two Corrosion Monitoring Probes One for CPrtK 2 Two Corrosion 120cc One Required Pipe holders and probes Container Phillips holders Teflon in U S A electric Signal Company LLC St Louis MO Phone 866 956 0988 Canada 888 882 1833 www pottersignal com 5401176 reV g 1 OF 4 Assemble the coupon on the coupon holder as shown in Fig 1 holder shown on the monitoring station label repeat steps 11 15 for the remaining coupon holders see Figs AND TeST KIT Verify that the isolation valves are in the open position and the monitoring station is free of any leaks Place the coupons in the bottom of the original shipping container the water sample bottle in the top of the original shipping insert the foam container into the pre addressed sleeve secure the tape Ship the container next day air service to the on the enclosed shipping label 1 Corrosion Coupon Assembly 2 Corrosion Monitoring Probe orientation required on pipe systems only LINE ON PLUG FACE TO COUPON FACE 1149 2 Pipe Systems with Riser Mount RM Version Use Turn the coupon rack from the sprinkler system Verify that the 1 2 drain valve is in the closed position remove 1 2 drain plug relieve system pressure from the coupon rack by opening the valve slowly Do not drain the coupon rack completely at time Use a container or bucket to catch the escaping water the water in the coupon rack will be pressurized to the pressure After the system pressure has been relieved the drain valve Fill the 120cc bottle by opening the drain valve slowly Close the drain valve Securely affix the cap to the bottle by making sure the cap screws tightly tape cap to bottle drain the remaining water from the coupon rack through the 1 2 valve into a container Close the 1 2 drain valve re install 1 2 plug into drain valve Locate the plastic document holder attached to the monitoring original coupon envelopes DO NOT HANDLe COUPONS OR PRObeS WITH bARe Notify to the corrosion monitoring probe remove the pressure from the probe if a union connection was used between pressure switch and the probe it will not be necessary to the wiring from the pressure switch remove the old and discard remove the corrosion monitoring probe from the sealed packag using the latex gloves provided and carefully remove the in U S A 5401176 reV g 1176 5 nPt FeMALe FOr PreSSUre threads and install the new probe in the same outlet the old was removed from install the pressure switch to the corro pressure switch if they were previously removed remove a coupon holder from the monitoring station Use a to loosen the plastic screw and nut see Fig 1 re the coupon from the coupon holder and place the coupon in corresponding original coupon envelope to the corrosion monitoring probe remove the pressure from the probe if a union connection was used between pressure switch and the probe it is not necessary to disconnect wiring from the pressure switch remove the old probe and install the new probe in the same outlet the old probe was re from install the pressure switch to the corrosion monitor if they were previously removed remove the new corresponding coupon from the new coupon do nOt discard the envelope steel locations are for C1010 coupons locations are for CdA 360 coupons Assemble the coupon on the coupon holder as shown in Fig 1 holder shown on the monitoring station label repeat steps 10 17 for the remaining coupon holders see Figs 2 OF 4 AND TeST KIT With the isolat

Related Files