Potter EVD-1 Electronic Vibration Detector
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-evd-1-electronic-vibration-detector-0425897163.pdf |
---|---|
Type | |
Size | 721.68 KB |
Downloads |
Text Preview
EVD 1 VIBRATION SYSTEM x 3.26 W x 1.20 D H x 8,3cm W x 3,0cm D and ULC Listed EVD 1 0.64 lbs 0,29 kg Die cast aluminum Stamped Steel 22 Gauge Input VDC to 16.0 VDC 12 VDC Nominal 0.1 V ripple If the EVD is going to be powered by auxiliary power of a burglar panel and the panel has ground fault detection it may be to power the EVD from a separate UL 12 VDC power supply Alternately the safe be insulated from ground Current Supply Voltage 12.0 VDC Standby Condition 26 mA Condition 24 mA Condition 34 mA model RTA connected add 10 mA in Tamper and 10 mA in Alarm Condition Current Supply Voltage 16.0 VDC Standby Condition 26 mA Condition 24 mA Condition 34 mA model RTA connected add 14 mA in Tamper and 14 mA in Alarm Condition No Information Detector Safe Pak EVD 1 Detector Security Safe Contact Equipment Remote Test Annunciator Security Cable Cable equipment required for UL safe complete installation EVD 1 is a stand alone detector For applications more than one detector the EVD 2 may be more For more information on the EVD 2 system bulletin no 8870015 Data Relay Form C 2.0 Amps at 30 VDC Contact Form A 2.0 Amps at 30 VDC Information EVD 1 Electronic Vibration Detector is listed by Underwriters Inc for primary protection of Mercantile or Bank safe vault ATM machines and supplementary protection of interior units as le cabinets display cases walls and ceilings The detector must used with an appropriate UL listed control unit Detects all common threats to safes and vaults Sophisticated signal processing provides unprecedented sensitivity false alarms Low cost stand alone system Reliable sensitive piezo sensor technology Integral multi color status LED Built in test circuit Remote test and annunciator capabilities Supervised microprocessor Independent tamper output On board test point facilitates installation and service Built in accumulator Controller EVD 1 controller detects short duration large amplitude signals those produced in attacks from explosions hammering or It also detects long duration small amplitude signals like produced in attacks from torches thermic lances drills grinders cutting discs As soon as the EVD 1 detects a large amplitude alarm it signals an alarm Construction Requirements 1 Maximum Linear Distances from Detector to Any Point the Protected Surface Construction Linear From to Any Point Pickup RV1 inches Safes Minimum 1 4 Minimum 1 2 Safes Minimum 16 steel over 3 material minimum steel over 3 material The Number Of Detectors For A Safe Application to column one in Table 1 for the type of the safe in the application column two nd the maximum linear distance from a detector to any on the protected surface This distance is the detector range Next to column one for steel safes or column two for composite in Table 2 Find the range of distances based upon the detector inches Electric Signal Company St Louis MO Phone 866 956 0988 Canada 888 882 1833 www pottersignal com IN USA 8870016 REV M 1 OF 3 that corresponds to the safe in the application Using the row of this range of distances determine the number of detectors from column if safe has a single door or from column four if safe has double doors For applications with a larger distance than that shown in Table consult Potter technical support for assistance VIBRATION SYSTEM D Maximum Linear Distance Safe Construction Minimum 1 4 Steel Minimum 1 2 Steel Safe Construction Minimum 16 Gauge Steel over 3 Material Minimum 1 4 Steel over 3 Material of Required Complete of Double Safes 4 EVD 2 Mounting Detector on Safe Door 2 Linear from Detector Any Point on Protected of Steel Safes Linear from Detector Any Point on Surfaces of Safes of Detectors for Coverage Single Door Safes minimum X1 X2 w d maximum X J the Maximum Linear Distance on a Safe rule of thumb for estimating the maximum linear distance from the detector location to any point on the protected surface is h 62 w 55 d 29 X1 62 55 X1 117 X2 2 x 29 55 X2 113 X 113 J 55 29 J 84 D 113 Compute X1 h w Compute X2 2d w Find Compute Find h Safe Height Safe Width Safe Depth Maximum Linear Distance rule of thumb is valid for most available safe sizes However if any dimension is very large or very small when compared to the other dimensions the safe may not follow this rule In those cases contact technical support for assistance Table 3 lists some common dimensions and their maximum linear distances when detectors are in recommended locations 3 Safe Exterior Dimensions and Maximum Linear Distances cu ft Maximum Linear inches IN USA 8870016 REV M 2 OF 3 VIBRATION SYSTEM continuous surfaces for several materials and sensitivity settings a surface extends around a corner via a solid connection detector extends into that surface but the coverage is reduced to 3 4 the remaining detector range All joints cracks and corners dampen borne vibrations Vibration transfer across these imperfections be tested to ensure complete coverage within the detector range constructions require one detector per panel and must be of the materials listed in Tables 1 and 4 1 Wall Protection Diagram Mounting Detector on Safe Door EVD 1 can be ounted on the safe door single door safes only the detector is mounted on the safe door the maximum linear decreases to 73.5 from the sensor location through the to all points on the safe body UL Complete Safe Installations Install in accordance with Underwriter Laboratories standard UL 681 Install EVD 1 detectors in recommended locations at recommended spacings Install UL listed high security contacts on the exterior of the safe UL listed ordinary use contacts on the inside of the safe Wire detectors and safe door contacts as shown in installation using high security cable Listed power supply or control unit must provide at least 4 hours of power for mercantile alarms and 72 hours of standby power bank vault alarms UL Complete Vault Installations Install in accordance with Underwriter Laboratories standard UL 681 Install EVD 1 detectors on interior walls ceilings and oors spaced shown in Figure 1 Refer to Table 4 for maximum spacing on materials A detector must be installed on the vault door if the net steel thickness less than 1 inches Wire detectors and door contacts as shown in installation instructions Listed power supply or control unit must provide at least 4 hours of power for mercantile alarms and 72 hours of standby power bank vault alarms Wall Protecti