Potter INS-PV Potter IntelliPurge® Nitrogen Purge Valve Installation, Operation, & Service Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-ins-pv-potter-intellipurge-nitrogen-purge-valve-installation-operation-service-manual-8271046953.pdf |
---|---|
Type | |
Size | 3.23 MB |
Downloads |
Text Preview
INS PV Potter IntelliPurge Purge Valve Operation Service Manual Electric Signal Company LLC Louis MO Service 866 240 1870 Technical Support 866 956 1211 Fax 314 595 6999 5401532 E of Contents 4 Overview 5 Going to the Job Site 7 of INS PV 8 and Networking 9 Guide for Non Networked INS PV 11 Guide for INS PVs Networked to an IntelliGen Series Nitrogen Generator 12 Using DIP switches 16 Series Menu Trees 19 Codes Trouble Shooting 26 Technical Specifications Drawings 28 Modes Functions and Definitions 29 Diagram 32 Policy 33 INS PVfirealarmresources com Safety Guidelines manual contains safety information that is important to know and understand This information is provided for the safety of operators and users of the Potter Nitrogen Generator as well as equipment To help recognize this information observe following symbols indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury indicates important information that if not followed may cause damage to equipment or property Notice to Users Installation and Owner Manual supplied with each unit must be read thoroughly and completely understood before and operation of the Potter Nitrogen Generator All appropriate safety standards for handling of gases as determined local or national laws and regulations should be followed at all times unpacking unit carefully inspect all parts and equipment for any damage that may have occurred during transit Make sure tighten fittings bolts etc before putting unit into service not operate if damage occurred during shipping handling or Contact Potter immediately Safety Information Read all of the safety information in this manual before operating this equipment Use of the equipment in a manner specified within this manual may impair the protection provided by the generator and could result in an unplanned release of which may cause serious injury or damage Only competent personnel who have been trained qualified and approved Potter Electric Signal Company LLC should perform commissioning servicing and repair procedures handling installing or operating this equipment personnel must employ safe engineering practices and observe all related regulations health and safety procedures and legal requirements for safety that the equipment is depressurized and electrically isolated before carrying out any of the scheduled maintenance specified in this manual warnings in this manual cover the most known potential hazards but by definition cannot be all inclusive If the user employs operating procedure item of equipment or a method of working that is not specifically recommended by Potter Electric Signal the user must ensure that the equipment will not be damaged or become hazardous to persons or property INS PVfirealarmresources com System Overview Potter IntelliPurge Nitrogen Purge Valve INS PV is designed to work with Potter IntelliGen Series Nitrogen Generators to effectively corrosive oxygen from a fire sprinkler system while maintaining adequate system pressure Potter IntelliPurge Nitrogen Purge Valve is easiest way to ensure high purity nitrogen is equally distributed throughout the fire sprinkler system Simply install the INS PV at the end of sprinkler system near a 24 Volt AC DC electrical connection When the nitrogen generator is in operation the INS PV bleeds out the oxygen one of three modes that are selectable using DIP switch configuration or by selecting the mode on the IntelliGen Nitrogen Generator The Purge Modes for the INS PV include Purge When the INS PV is in Perfect Purge Mode the unit purges the air out of the system until 98 N2 purity is reached This is the unit default setting Shot In this mode a Purge Time is selected and the valve automatically shuts off after that time expires This mode is designed for freezers or ice plug applications After the system reaches 98 purity it will cyclically open and This allows any excess trapped moisture to be periodically purged while still lowering the duty cycle at the compressor additional information on Purge Modes see page 29 the event of a system activation the INS PV has a built in high pressure water shut off valve that automatically closes when the water reaches vent A ball valve allows for isolation of the assembly maintenance of strainer screen replacement of air vent or maintenance of the purge See Figure 1 for INS PV System Diagram 1 INS PV System Diagram FROM SPRINKLER SYSTEM 20 1 4 7 1 8 7 3 8 NPT TEE CONNECTION AND CLOSE NIPPLE BY SPRINKLER CONTRACTOR TEST VALVE POSITION VENT ORIFICE INS PV BALL VALVE SHOWN CLOSED NON PURGE POSITION INS PVfirealarmresources com 2 Typical INS PV External View Latch Toggle Switch Toggle Switch Exhaust Definitions on page 30 for further information Level Display LED LED LED Time Display INS PVfirealarmresources com Before Going To The Jobsite On arrival do a full inspection by checking all packages and crates in the shipment for damage If damage is found sign for damage or refuse the shipment Contact the carrier immediately and file a shipping damage claim with the carrier Check to ensure all components are contained and no visible damage has occurred during shipping List Transformer PV 5270462 1119478 1119478 Read all of the safety information in this manual before installing or operating this equipment Find a location to install the INS PV that meets these requirements to front and top for maintenance located near power requirements 24 Volt AC DC for INS PV 7.3 x 6.8 x 7.9 H x W x D clean well ventilated covered and away from high voltage power temperatures between 4 20 and 122 50 INS PV should always be installed in an adequately ventilated room Nitrogen is nontoxic and largely inert release of nitrogen gas into an enclosed space displaces the oxygen and can cause an asphyxiation hazard of nitrogen in excessive concentrations can result in unconsciousness without any warning symptoms Run a 24 Volt AC DC wire to installation location for INS PV Class 2 Transformers available for 120 V application gage must be considered when running power for long to the INS PV Refer to Figure 3 3 For PLINK networking the INS PV requires 3 signal lines to allow communication PL A PL B and PL G The PLINK network requires 3 wire twisted stranded cable CAT5 cable with the unused wires trimmed is recommended