Potter Installation Manual PAD100-PSSA PSDA Pull Station (Single & Dual Action)

File Preview
File Preview
Click below to download for free

Text Preview

Installation Manual PAD100 PSSA PSDA Pull Station Single Dual Action TO THE INSTALLER manual provides an overview and the installation instructions for the PAD100 PSSA PSDA Single Action Dual Action This module is only compatible with addressable fire systems that utilize the PAD Addressable Protocol terminals are power limited and should be wired in accordance with the requirements of NFPA 70 NEC and NFPA 72 National Alarm Code Failure to follow the wiring diagrams in the following pages will cause the system to not operate as intended For information refer to the control panel installation instructions module shall only be installed with listed control panels Refer to the control panel installation manual for proper system Description PAD100 PSSA Single Action is activated by pulling the white T bar handle down The PAD100 PSDA Dual Action is by lifting the front cover and then pulling the white T bar handle down Once activated the T bar cannot be reset opening the front cover Opening the front cover will also activate the pull station To reset the PAD100 PS series use the WS 93 key to unlock and open the front cover Once the cover is open push the T bar back into the normal position and the front cover It is a non coded addressable pull station and installs on a single gang box or surface mounts using the or P32 DBB deep back box Setting the Address PAD protocol detectors and modules require an address prior to connection to the panel SLC loop Each PAD device i e detector and or module is set by changing the dip switches located on the device PAD device addresses are of a seven 7 position dip switch used to program each device with an address ranging from 1 1 PAD Device Dip Switch Addresses Table Addresses 1 16 32 64 16 32 64 16 32 64 16 32 64 16 32 64 16 32 64 Each gray box indicates that the dip switch is On and each white box indicates Off 16 32 64 16 32 64 16 32 64 16 32 64 examples shown below illustrate a PAD device dip switch settings the 1st example shows a device not addressed where all switch settings are in the default Off position the 2nd illustrates an addressed PAD device via the dip switch settings 2 Examples of PAD Device Showing Default Dip Switch Setting Unaddressed Addressed PAD Device 4 64 4 64 dip switches are in the Off shows this PAD device 42 Dip switches 2 8 are in the On position Electric Signal Co LLC St Louis MO Phone 866 956 0988 www pottersignal com 5406320 A 02 16 PAGE 1 OF 3 to the SLC is removed wiring on module is correctly installed wiring has no open or short circuits connecting a device to the SLC loop take the following precautions to prevent potential damage to the SLC or device Technical Specifications Voltage SLC Standby Current SLC Alarm Current Range Humidity Range Options Weight A A to 120 F 0 to 49 C to 93 non condensing L x 3.25 W x 1.75 D gang box or Potter P32 BB DBB lbs 1.46 lbs Wiring Diagrams wiring diagram shown below illustrates how to wire a PAD100 PSSA PSDA module Additionally two drawings are provided the front view of each module 3 Example of Back View and Wiring a PAD100 PSSA PSDA WIRED CONTACTS FACP OR DEVICE NEXT DEVICE Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406320 A 02 16 PAGE 2 OF 3 MANUAL PAD100 PSSA PSDA PULL STATION SINGLE DUAL ACTION firealarmresources com 4 Examples of PAD100 PSSA PSDA Front Views POTTER POTTER wiring style supports the Class A Class B and Class X loop wiring SLC SLC are power limited Wiring for terminals SLC SLC are supervised wiring is between 12 max and 22 min Wire Preparation Strip all wires 1 4 inch from their edges as shown here inch Stripping too much insulation may cause a ground fault Stripping too little may cause a poor connection and subsequently an open circuit instructions do not purport to cover all the details or variations in the equipment described nor provide for possible contingency to be met in connection with installation operation and maintenance subject to change without prior notification Technical Assistance contact Potter Electric Signal Company at 866 956 1211 performance is based on proper application of the product by a qualified professional further information be desired or should particular problems arise which are not covered sufficiently for purchaser purpose the matter should be referred to a distributor in your region Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal com 5406320 A 02 16 PAGE 3 OF 3 INSTALLATION MANUAL PAD100 PSSA PSDA PULL STATION SINGLE DUAL ACTION firealarmresources com

Related Files