Potter IPA-4000 City of Chicago Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Features addresses available on this analog addressable system system capacity achieved via multi point SLC modules software zones 72 Compliant Smoke Sensitivity Test Built In Operates as Class A or Class B for SLC P Link and NACs Amp Power Supply NACS Regulated Rated at 3 Amps each Input Output I O Circuits for system flexibility rated at 1 Amp each Synchronization and System Wide Sync for Potter AMSECO Cooper Wheelock and System Sensor strobes Alarm Supervisory and Trouble Relays Event History Buffer will house up to 18 AH batteries two line DACT with UD 2000 that can report General Zone or Information in IP communicator Port for Programming and Network Connectivity System Status Reports and Event Information includes 5 year warranty IPA 4000 is an expandable analog addressable releasing fire alarm with a total system capacity of 4,064 addresses Additional on the system is achieved using multi point SLC modules control panel utilizes the exclusive Potter protocol that includes a line of sensors and modules The system is expandable with a of thirty one additional addressable Signaling Line Circuits SLC with a maximum of 127 devices Each SLC may be comprised of any of smoke sensor heat detectors or modules and allows for a of 50 ohms of impedance and may use any wire compliant with the Electrical Code NEC IPA 4000 has a 10 Amp power supply with six Notification Circuits NACs and four Input Output I O circuits The are rated at 3 Amps each and the I Os are rated at 1 Amp each output is regulated and power limited In addition each output is programmable and may be configured for steady signal strobe constant power door holder power or releasing The synchronization includes Potter AMSECO Gentex System Sensor Cooper Wheelock and with the exclusive Quadrasync each output have a unique brand and all strobes will flash together The I Os are for inputs such as manual release stations and abort switches that not require polling and react nearly instantaneously IPA 4000 is listed for releasing of fire suppression systems The allows cross zones counting zones and timers for suppression system is capable of multiple release outputs across multiple hazards addition the PSN 1000 may be used to extend releasing capability NACs may be expanded using the PSN 1000 series intelligent power Each PSN 1000 adds another 10 Amps of power 2 additional circuits and the IPA 4000 will support up to 31 power supplies The will synchronize the strobes system wide In addition the PSN has space to allow the installation of up to six PAD100 SLCE SLC expansion cards The cards mount on a stacker bracket that allows to all SLC circuit connections of Chicago 1 Addressable Approved Specifications Mains and Range 15 16 x 27 5 16 x 4 7 16 Amps 120 VAC 50 60 HZ Amps 240 VAC 50 60 HZ gauge cold rolled steel with removable door with Lexan viewing window Current 130 mA Current 220 mA 10 Amps power for NACs I O and P Link 3 Amps per NAC regulated 1 Amp per I O circuit regulated Battery Charger range 8 55 Ah Battery Charger voltage 27.3 VDC P Link maximum current of 1 Amp to 120 0 to 49 with a maximum of 93 non condensing ANSI UL 864 Local L Remote Sta RS Central Station CS Propriety Auxiliary AUX Type of Service A Manual M Water flow Sprinkler Supervisory SS Type of Digital Alarm Communicator March Time March Non Coded Reverse Polarity Rev Pol Other OT We recommend using a non synchronized NAC circuit for signals when using the Potter EH24 HS 24 or CHS series devices to produce a steady non temporal pattern For visual signaling strobes should be controlled separately a NAC circuit that provides Gentex synchronization protocol page 1 OF 5 REV C 1 20Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comIPA 4000Fire Alarm Control PanelCity of Chicago Class 1 Addressable Approvedfirealarmresources com Loop Accessories control panel may be connected with up to 4,064 addressable or modules in any combination The SLC is not restricted by special wire requirements and may be wired with any wire that with the NEC Features Potter protocol is a digital protocol with a proven design for and noise immunity The system does not require special or conductors for connection of the Signaling Line Circuit long as the cable is compliant with NFPA 70 and NFPA 72 system allows for Class A or Class B installations as well as loop is capable of 127 points with a max wiring of 10,000 ft Features sensors through the fire alarm control panel provide a real status as to the condition of the system The smoke detector heat detector temperature level and drift compensation all programmable options The system also allows for a day night where the panel automatically adjusts the sensitivity depending the time of day To assist in the reduction of false alarms the detectors also have a maintenance warning that sends a trouble when a detector is dirty to the point that it can no longer the programmed sensitivity Interface fire alarm control panel has a 4 x 40 LCD display to provide to the system status The keypad has navigation keys allow manipulation of the Menu on board the panel The panel is standard with the following LEDs AC Power Green Alarm Red common buttons include a Silence Reset Acknowledge and All of the buttons are accessible once the locked door is Fault Amber Amber Amber Amber Amber Red IPA 4000 has a proprietary communication protocol that through a RS 485 connection to field devices Up 64 devices may be connected to a single P Link connection The includes the communication terminals and regulated 24 VDC for the field devices The field devices may be any of the loop expansion module of 31 per IPA 4000 2 x 16 LCD annunciator with a key pad in a locked enclosure 4 x 40 LCD annunciator with a key pad in a locked enclosure Flush mount version available 16 LED annunciator with common indicators in a metal enclosure Flush mount version available 10 amp remote intelligent power supply with NACs 2 Inputs and a P Link repeater This panel is listed in with the IPA 4000 as releasing circuits Class A convertor that converts the SLC NACs and connection UL listed Dual line telephone alarm communicator LED driver expander used to connect up to 50 LEDs in a display Fire communication bridge provides remote mounting the Ethernet connection Fiber interface module used to extend P Link to multi fiber 2 required Relay module provides 5 form C relay contacts rated at 3.0 24VDC 125AC Serial parallel gateway allows for the connection to a or parallel printer FIB 1000 FCB 1000 and the SPG 1000 may be installed in the bracket or ordered with the optional rack mount enclosure Multi Connect allows up to sixty three IPA series panels to a single reporting technology Two card expansion cabinet Eight card expansion cabinet Fourteen card expansion cabinet Connection IPA 4000 is shipped standard with an Ethernet connection connection is the programming port and may be connected a building Wide Area Network WAN or Local Area Network Once connected to the Internet the panel may be selectively to e mail alarm conditions trouble conditions conditions test Event History and detector status An may be sent to the panel and the panel will e mail the event detector status configuration file or server status to an E mail account In addition reminders may be set

Related Files