Potter LRM Solenoid Kit Advanced Leak Rate Monitor Solenoid Kit
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-lrm-solenoid-kit-advanced-leak-rate-monitor-solenoid-kit-8730216459.pdf |
---|---|
Type | |
Size | 968.83 KB |
Downloads |
Text Preview
Features Designed for use with the IntelliCheck Advanced Leak Rate Allows users to perform leak tests on systems with dedicated air or nitrogen generators Allows users to monitor aspects of air compression or nitrogen systems LRM Solenoid Kit is designed to be used with sprinkler systems utilize a dedicated air compressor or nitrogen generator The kit will allow a leak test of the system by isolating the air from the system with the LRM Controller current transformer that is included with this kit will allow the to track run times and cycle counts on their air source as well will allow the user to keep track of when to do maintenance and make the user aware of other issues on the air source included check valve is necessary to keep water and sediment getting to the solenoid and air supply Specifications Pressure Temperature psi above 32 FNPT Inlet and Outlet Brass Construction FNPT Inlet and Outlet Construction Valve Size and Size and PAGE 1 OF 2 Solenoid KitAdvanced Leak Rate Monitor Solenoid Kit5403777 REV A 1 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Solenoid Kit Installation Solenoid Kit is required when a tank is supplying the system LRM Solenoid Kit must be installed within reach of the provided 7 solenoid cable to the LRM Display FNPT LRM Solenoid in line of the air supply after the compressor or AMD and the kit supplied 1 2 check valve See The supplied check valve with 1 2 FNPT inlet and outlet will need to be installed inline and between the solenoid and transducer the flow arrow on the check valve is in the direction of the supervisory gas flow See below Leak check new connections supplied solenoid DIN cable onto the solenoid and run the opposite end through a supplied strain relief fitting and a knockout the LRM Housing wires into the bottom 3 terminals of the 10 terminal block by depressing orange tab inserting wire and releasing tab on the Controller See IntelliCheck Manual 5403773 for more detail SUPPLY SUPPLY Information Solenoid Kit No PAGE 2 OF 2 REV A 1 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comLRM Solenoid KitAdvanced Leak Rate Monitor Solenoid Kitfirealarmresources com