Potter NGP-1000D-M2 Nitrogen Generator with 1,000 Gallon Largest Riser Fill and 3,000 gallons of Total Sprinkler System Capacity
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-ngp-1000d-m2-nitrogen-generator-with-1000-gallon-largest-riser-fill-and-3000-gallons-of-total-sprinkler-system-capacity-6817594032.pdf |
---|---|
Type | |
Size | 1.58 MB |
Downloads |
Text Preview
Features Complete skid mounted unit easy plug and play installation Integrated 2 HP oil less air compressor needed for NFPA 13 required minutes fill for 1000 gallon system at 40 PSI Handles up to 3000 gallons of total sprinkler system capacity based NFPA 13 allowable leak rates for a new sprinkler system Premium nitrogen membrane UL 508A listed industrial control panel Requires only one power connection Built in Programmable Logic Controller for leak detection and air alarm systems Form C dry contacts for Building Management System BMS 30 gallon air tank and 30 gallon nitrogen tank Includes all filters relief valves automatic drains and gauges Potter Nitrogen Generator NGP 1000D M2 is specifically to provide on site high purity nitrogen for use in fire sprinkler systems When used as a supervisory gas in fire systems nitrogen slows corrosion improves the life of your and lowers maintenance costs Potter Nitrogen Generators are assembled packages ready to be connected to a new or existing sprinkler system These turn key systems include all air filtration an air compressor nitrogen membrane as well as tanks to keep the generator operating at peak efficiency Potter Generator Systems provide a low cost reliable and efficient of producing a minimum of 98 nitrogen at the point of usage NGP 1000D M2 utilizes nitrogen membrane technology for separation Nitrogen membranes are highly effective and a cost way of producing on site nitrogen Acting as a filter the oxygen and water vapor molecules can pass through the quickly The larger nitrogen molecules are less likely diffuse through the separator tubes therefore they continue to the separator outlet through the air maintenance device into the fire protection system As the system fills with nitrogen remaining oxygen molecules in the fire protection system are by using the Potter IntelliPurge Nitrogen Purge Valve The IntelliPurge Nitrogen Purge Valve will periodically monitor fire protection system to ensure high purity nitrogen is consistent the sprinkler system Potter NGP 1000D M2 should be installed in a dry clean and room with ambient temperatures above 50 at all times access to the front for service and place the unit in a location is conveniently located near fire sprinkler system connections and drain Potter Nitrogen Generator should always be installed in an ventilated room Nitrogen is nontoxic and largely inert release of nitrogen gas into an enclosed space displaces the and can cause an asphyxiation hazard Inhalation of nitrogen excessive concentrations can result in unconsciousness without any symptoms detailed installation and operation instructions please refer to the Nitrogen Generator Manual 5401548 Specifications HxWxD x 44 x 33 lbs in 208V 11.6A 230V 11A phase and 208V 9.2A 230V 9.2A 4.6A three phase Supply Sprinkler System Holes Operating Pressure Range Purity Female NPT PSI 10 to 110 43 Class 1.4.1 or better Free of water 3 Dew Point compressor oil PPM or 01 mg m3 hydrocarbons particles 0.01 microns PAGE 1 OF 2 Generator8820025 REV A 7 15Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com LESS AIR 1 3 4 MOUNTING HOLES MOUNTING HOLES PLCS PLCS 3 4 3 4 CHG NO LESS AIR LESS AIR TANK PRESSURE SWITCH UNLOADER MOUNTING HOLES PLCS 3 4 ON LIGHT SOLENOID LIGHT HORN PRESSURE TANK GAUGE PRESSURE SWITCH PRESSURE SWITCH UNLOADER UNLOADER 1 8 CONDUIT PLCS 5 8 PRESSURE SWITCH UNLOADER 1 8 1 8 CONDUIT CONDUIT PLCS PLCS GALLON TANK 1 8 FNPT NITROGEN CONNECTION PLCS HORN PRESSURE TANK GAUGE OD TUBING OD TUBING TO CONNECT TO CONNECT 5 8 5 8 OD TUBING TO CONNECT PLCS 5 8 5 8 CONDUIT PLCS OD TUBING TO CONNECT 5 8 GALLON TANK 7 8 5 8 5 8 5 8 5 8 3 8 5 8 5 8 PLCS PLCS PLCS 7 8 7 8 3 8 3 8 3 8 7 8 Information PHASE 208V PHASE 230V PHASE 208V PHASE 230V PHASE 460V No Kit M2 M5 IntelliPurge Nitrogen Purge Purge Valve Air Maintenance Device No LESS AIR VALVE ON LIGHT ON LIGHT SOLENOID SOLENOID LIGHT LIGHT HORN HORN PRESSURE PRESSURE SOLENOID ON LIGHT TANK TANK GAUGE GAUGE LIGHT GALLON GALLON TANK TANK GALLON TANK OD TUBING OD TUBING TO CONNECT TO CONNECT CERTIFIES ALL PARTS SUPPLIED FROM THIS DRAWING HAVE BEEN PRODUCED ITS SPECIFICATIONS AND VENDOR WILL BE RESPONSIBLE FOR ANY REWORK COST SPECIFICATIONS HAVE NOT BEEN MET OD TUBING TO CONNECT CERTIFICATION DATA CONTAINED HEREIN SHALL NOT BE USED DUPLICATED OR DISCLOSED IN WHOLE PART OUTSIDE POTTER ELECTRIC INC WITHOUT WRITTEN PERMISSION OF SAME ELECTRIC SIGNAL CO GENERATED DRAWING NOT MANUALLY UPDATE NOT SCALE DRAWING GALLON GALLON TANK TANK DWG NO GALLON TANK OF 1 PAGE 2 OF 2 REV A 7 15Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comNGP 1000D M2Nitrogen Generatorfirealarmresources com