Potter PAD100-IB Addressable Isolator Base

File Preview
File Preview
Click below to download for free

File Data

Name potter-pad100-ib-addressable-isolator-base-8360179524.pdf
Type PDF
Size 1.27 MB
Downloads

Text Preview

Features Isolator integrated into base Self restoring Red LeD indication of short circuit Terminals accept 22 to 12 aWg wire sizes Supports Class a Class X and Class B wiring Does not require SLC Loop address UUKL Listed for Smoke Control addressable Isolator Base 6 paD100 IB comes with an isolator module included The base has a locking feature for sensor that may be used or removed in the field Once the head is the isolator is accessible in the bottom of the unit isolator will open the Signaling Line Circuit down stream when a circuit is detected This will provide devices between the control and the isolator to continue to operate The short is indicated by steady red LeD and once the short is removed the unit will return to operation VDC LeD red a B and X Specifications Range for SLC indicator SLC wiring style number of per SLC Loop temperature range 32 to 120 0 to 49 relative humidity without White 0.75 in 19mm 6.3 in 166 mm to 93 Non condensing page 1 OF 2 Isolator Base 8830105 REV C 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Base Mounting should be mounted directly on the electrical box The holes are configured for a single gang double gang octagon 4 square box See Fig 1 1 the two included attached the base to detector Features of Detector Head from Base To remove the detector from the base once the locking feature has activated insert a small screwdriver into the slot on the base to the plastic tab while simultaneously turning the detector head See Fig 3 3 small screwdriver slot to remove from base To remove the base cover from the lower enclosure once the locking has been activated insert a small screwdriver into the slot on on the base to push the plastic tab while simultaneously turning the head counter clockwise Information Isolator Base No Feature the Locking Feature include a locking feature that prevents removal of the and removal of the base cover without using a tool To eliminate this feature break off the locking tab refer to Figure and then install the detector See Fig 2 2 the detector to the back box the mounting off tab gray in image to disable feature page 2 OF 2 REV C 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD100 IBAddressable Isolator Base firealarmresources com

Related Files