Potter PAD100-SM Speaker Module

File Preview
File Preview
Click below to download for free

File Data

Name potter-pad100-sm-speaker-module-2046173859.pdf
Type PDF
Size 1.11 MB
Downloads

Text Preview

Features Single module with two 2 channel audio inputs One 1 Class B or Class a audio output channel SLC Class a Class X Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box all wiring terminals accept 22 to 12 aWg Switches maximum 60 watts product includes a 5 year warranty UUKL Listed for Smoke Control paD100 SM uses one 1 SLC loop address The module mounts either a 4 square or double gang box The module is capable of one of the two audio input channels to its audio output The paD100 SM includes one red LeD to indicate the status In normal condition the LED flashes when the device being polled by the control panel paD100 SM is compatible with potter Ipa and aFC aRC series fire alarm control panels The PAD100 SM is an audio module to be used in audio switching applications the Address addressable SLC device must be assigned an address The is set using the DIp switch located on the paD100 SM each channel is identified as a sub point of the module address For if the address number is assigned as the first input will be and the second input channel will be connecting a device to the SLC loop take the following to prevent potential damage to the panel or device Power to the device is removed Field wiring is correctly installed Field wiring has no open or short circuits Specifications Voltage SLC Standby SLC alarm Output Rating Resistor Temperature Humidity no of Module per Options Weight 30VDC 0.5a 125VaC 60 to 120 0 to 49 to 93 non condensing units 106mm L 4.17 1.14 29mm D 4 Square or gang Box lbs page 1 OF 2 Module8830093 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Using Compatible Electrical Box 1 Diagrams With One Class B Output Channel 2 With One Class A Output Channel 3 FACP OR MODULE NEXT MODULE AMPLIFIER 1 AMPLIFIER 2 FACP OR MODULE NEXT MODULE AMPLIFIER 1 AMPLIFIER 2 Class B Wiring RESISTOR OHM W 3005021 Class A Wiring END OF LINE RESISTOR NOT REQUIRED is possible that the internal relay in the PAD100 SM may be shipped in the non normal activated state To ensure that the internal relay is set to the state connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output Information Module No page 2 OF 2 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD100 SMSpeaker Modulefirealarmresources com

Related Files