Potter PAD100-TRTI Two Relay Two Input Module
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-pad100-trti-two-relay-two-input-module-1579643820.pdf |
---|---|
Type | |
Size | 1.13 MB |
Downloads |
Text Preview
Features Single module with dual contact monitoring inputs Two 2 Class B or one 1 Class a monitoring inputs Two 2 Form C relay contacts SLC Class a Class X Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG product includes a 5 year warranty UUKL Listed for Smoke Control This addressable module does not support 2 wire smoke paD100 TRTI uses one 1 SLC loop address when monitoring 2 Class B circuits or one 1 Class a circuit The paD100 TRTI provides two 2 Form C relay contacts The module mounts either a 4 square or double gang box The module is capable monitoring two 2 separate Class B circuits making it ideal for sprinkler waterflow and valve tamper switches when they located in the same proximity The paD100 TRTI includes one LeD to indicate the module status In normal condition the LeD when the device is being polled by the control panel When an is activated the LED will flash at a fast rate paD100 TRTI is compatible with potter Ipa and aFC aRC addressable fire alarm control panels The PAD100 TRTI is interface module used to monitor dry contact devices such as waterflow valve tamper switches or conventional pull The module is capable of monitoring two separate Class or one Class a circuits The paD100 TRTI also provides two 2 C relay contacts the Address addressable SLC device must be assigned an address The is set using the DIp switch located on the paD100 TRTI The paD100 TRTI is assigned a single device address each input and is identified as a sub point of that single module address For if the address number is assigned as the RLY1 relay be the RLY2 relay will be the B1 input will be the B2 input will be connecting a device to the SLC loop take the following to prevent potential damage to the panel or device power to the device is removed Field wiring is correctly installed Field wiring has no open or short circuits 30VDC 0.5a 125VaC Specifications Voltage SLC Standby Current SLC alarm Current Contacts Wiring Resistance of Wiring Capacitance of Resistor Temperature to 120 0 to 49 Humidity Range to 93 non condensing no of Module per Loop 127 units Options Weight 106mm L 4.17 1.14 29mm D 4 Square or gang Box lbs page 1 OF 2 Relay Two Input Module8830080 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Using Compatible Electrical Box 1 Diagrams With One Class A Circuit 2 FACP OR MODULE NEXT MODULE RESISTOR NOT REQUIRED With Two Class B Circuits 3 FACP OR PREVIOUS MODULE THE NEXT MODULE OHM 1 W 3005013 OHM 1 W 3005013 THE DIP SWITCH POSITION CLASS A WIRING 2 FORM C CONTACTS THE DIP SWITCH POSITION CLASS B WIRING 2 FORM C CONTACTS is possible that the internal relay in the paD100 TRTI may be shipped in the non normal activated state To ensure that the internal relay is set to the state connect the module to the SLC loop and reset the control panel before terminating the wiring to the modules output Information No Two Relay Two Input Input Module 3992701 page 2 OF 2 REV D 12 18Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPAD100 TRTITwo Relay Two Input Modulefirealarmresources com