Potter PFC-4064 Conventional Fire Alarm Panel Keypad Programming Guide
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-pfc-4064-conventional-fire-alarm-panel-keypad-programming-guide-5703296148.pdf |
---|---|
Type | |
Size | 7.05 MB |
Downloads |
Text Preview
PFC 4064 Fire Alarm Panel Programming Guide Electric Signal Company LLC Louis MO Service 866 240 1870 Technical Support 866 956 1211 Fax 314 595 6999 8870080 A INFORMATION essential purpose of any sale or contract for sale of any of the products listed in the POTTER catalog or list is the furnishing of that product It is expressly understood that in furnishing said product POTTER not agree to insure the Purchaser against any losses the Purchaser may incur even if resulting from the of said product warrants that the equipment herein shall conform to said descriptions as to all affirmation of and shall be free from defects of manufacture labeling and packaging for a period of one 1 or 5 year s depending on the product from the invoice date to the original purchaser provided that samples are returned to POTTER for inspection The product warranty period is stated on exterior of the product package Upon a determination by POTTER that a product is not as warranted shall at its exclusive option replace or repair said defective product or parts thereof at its own except that Purchaser shall pay all shipping insurance and similar charges incurred in connection the replacement of the defective product or parts thereof This Warranty is void in the case of abuse abnormal usage faulty installation or repair by unauthorized persons or if for any other reason determines that said product is not operating properly as a result of causes other than defective labeling or packaging Aforesaid Warranty Is Expressly Made In Lieu Of Any Other Warranties Expressed Or Implied It Understood That All Such Other Warranties Expressed Or Implied Including The Warranties Of And Fitness For Particular Purpose Are Hereby Expressly Excluded In No Event Shall Be Liable To Purchaser For Any Direct Collateral Incidental Or Consequential Damages In With Purchaser Use Of Any Of The Products Listed Herein Or For Any Other Cause Whatsoever To The Said Products Neither Potter Nor Its Representatives Shall Be Liable To The Purchaser Anyone Else For Any Liability Claim Loss Damage Or Expense Of Any Kind Or Direct Collateral Or Consequential Damages Relative To Or Arising From Or Caused Directly Or Indirectly By Said Or The Use Thereof Or Any Deficiency Defect Or Inadequacy Of The Said Products It Is Expressly That Purchaser Exclusive Remedy For Any Cause Of Action Relating To The Purchase And or Use Any Of The Products Listed Herein From Potter Shall Be For Damages And Potter s Liability For Any And Losses Or Damages Resulting From Any Cause Whatsoever Including Negligence Or Other Fault Shall No Event Exceed The Purchase Price Of The Product In Respect To Which The Claim Is Made Or At The Of Potter The Restoration Or Replacement Or Repair Of Such Product Electric Signal Company LLC Phantom Drive Ste 125 St Louis MO 63042 314 595 6900 800 325 3936 KEYPAD PROGRAMMING 8870080 REV A 12 17firealarmresources com of Contents 1 Introduction 1 2 Pre Programming Procedures and Defaults 2 3 Operation 4 4 Programming Options 6 5 Manual Programming Overview 9 Programming Cycle 9 Setup Software Zone Attributes 9 Setup Points 10 Setup Assign Zones 12 Programming 14 6 DACT Programming 15 7 Panel Menu Trees 18 KEYPAD PROGRAMMING 8870080 REV A 12 17firealarmresources com PAGE INTENTIONALLY LEFT BLANK KEYPAD PROGRAMMING 8870080 REV A 12 17firealarmresources com 1 Introduction PFC 4064 Conventional Fire Panel is a compact expandable panel designed to monitor all facets of a fire alarm system communicate the status to a monitoring station The PFC 4064 panel is a listed and approved microprocessor based fire panel and complies with UL 864 NFPA 70 and NFPA 72 Of This Manual manual is intended to assist in the programming of the PFC 4064 Conventional Fire Panel via its keypad Refer to this to properly program the PFC 4064 It is recommended that the user follows the procedures as outlined in this manual assist in proper programming and prevent damage to the control panel and associated equipment Overview PFC 4064 system is designed for use as a fire control panel for life safety applications Features Limited in Sync and Temporal Patterns to activate on a Supervisory condition PFC 4064 has six 6 programmable input circuits and is expandable to 192 using thirty one 31 IDC 6 cards each six 6 additional programmable input circuits 4 Notification Appliance Circuits NAC rated at 3.0A maximum y y y y for all major strobe synchronization patterns y Gentex y AMSECO y Wheelock y Sensor Auto Silence and Silence Inhibit Ethernet port for programming and network connectivity Email support to communicate system status and event information Reminder Emails event non volatile history buffer Software Zones X 20 character LCD display IP Reporting To Use This Manual to this manual before contacting Technical Support The information in this manual is the key to a successful and will assist you in understanding proper system start up device designation and other guidelines specific to PFC 4064 system KEYPAD PROGRAMMING 8870080 REV A 12 17firealarmresources com 2 Pre Programming Procedures and Defaults beginning PFC 4064 programming install the panel following the directions included in the PFC 4064 Installation Operations Manual Potter document 5403638 Failure to properly install and wire the physical panel and any devices being used in conjunction with it can result in system errors and difficulty in programming as well as potentially the fire alarm system Defaults Input Circuit PFC 4064 has a total of 6 built in input circuits available for use These inputs are for monitoring devices such as smoke pull stations and waterflow switches The terminals for input devices shown below are located at the top right of the control panel circuit board Each circuit has a factory default setting that can be used to connect to a specific of input device for ease of installation and programming Defaults Output Circuit PFC 4064 has a total of 4 built in output notification appliance circuits NACs available for use These outputs are for devices The output NAC terminals shown below are located at the bottom right corner of the control panel board Each circuit has a factory default setting that can be used to connect to a specific type of output device for ease installation and programming Terminal Default Settings Type Station Fire Alarm Fire Alarm Supervisory Output Terminal Default Settings Activation Setting Type Only Alarm Alarm Alarm KEYPAD PROGRAMMING 8870080 REV A 12 17firealarmresources com Defaults Relay Circuit PFC 4064 has a total of 4 built in relays available for use The relays shown below are located along the central bottom of the control panel circuit board Output Terminal Default Settings Activation Setting Type