Potter PFC-6030 30 Point Addressable Fire Alarm Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-pfc-6030-30-point-addressable-fire-alarm-control-panel-4512683097.pdf |
---|---|
Type | |
Size | 1.52 MB |
Downloads |
Text Preview
Features Analog Addressable Points in Any Combination Amp Power Supply NACS Regulated Rated at 3 Amps each Synchronization and System Wide Sync for Potter Gentex Cooper Wheelock and System Sensor Wide Class A or B Software Zones LCD and Keypad for Ease of Operation will house 8 or 18 Ah batteries Dead Front Cabinet for Look Detector Drift Compensation and Maintenance Alerts NFPA 72 Compliant Smoke Sensitivity Test Built In Optional two line DACT with UD 1000 that can report General Event History Buffer or Point Communication Line for Annunciators and Accessories System Status Reports and Event Information listed IP Communicator Port for Programming and Network Connectivity Specs AC Mains Amps 120 VAC 50 60 H2 Amps 240 VAC 50 60 H2 mA Standby Alarm x H x D 16 x 17 x 3 7 8 Fire Dept of Approval includes a 5 year warranty PFC 6030 is a versatile thirty point analog addressable fire alarm control panel that utilizes the Potter Nohmi device protocol that has a line of initiating and control devices The SLC is capable of 50 ohms of resistance and does not require the use of twisted or shielded The thirty 30 points may be any combination of smoke sensors heat detectors or modules PFC 6030 has a metal cabinet with a key lock and a dead front standard The cabinet will house 8 Ah or 18 Ah batteries The large viewing allows easy viewing of the LCD and the standard LEDs The keypad allows easy operation and navigation of the system menu of the outputs are power limited are power regulated and may be programmed for Potter AMSECO Gentex CooperWheelock and Sensor strobe synchronization The outputs may be configured for any combination of strobe brands and all will sync The outputs also be configured for door holder power auxiliary power and constant power panel has auto programming learn mode that will not affect the existing system when adding or deleting a device The system is capable 99 software zones cross zoning and counting zones The panel is fully programmed from a PC based software program that will work with XP Vista or Windows 7.0 operating systems PFC 6030 has an Ethernet connection for programming network connectivity and IP reporting communicator The system uses a simple cable for connecting a PC to the panel In addition the system may be connected to a building network and programmed while on the The system has a built in e mail function and will send system E mail reminders The IP communicator is listed with the Sur Gard III receiver panel will support P Link devices which include the RA 6075 RA 6500 and LED 16 Annunciators RLY 5 Relay Module SPG 1000 Se Parallel Gateway printer card an FCB 1000 Remote Ethernet IP connection DRV 50 LED driver for 50 LEDs PSN 1000 Remote Power 10 Amp and FIB 1000 P Link Fiber Interface Module In addition the panel allows for the installation of the UD 1000 dual line line digital alarm communicator transmitter DACT The UD 1000 is programmable for a single line or dual line and is compatible Ademco Contact ID or SIA DCS protocols complete system may be converted to Class A with a CA 6075 module The CA 6075 provides the hardware necessary to convert the re annunciators through the Potter P Link connection protocol the NACs and the SLC to Class A operation Electric Signal Company LLC St Louis MO Cust Service 866 956 1211 Tech Support 866 240 1870 Canada 888 882 1833 www pottersignal com 1 OF 3 8830024 REV A11 13PRINTED IN USAPFC 6030FIRE ALARM CONTROL PANELfirealarmresources com Loop Accessories control panel may be connected with up to thirty 30 addressable devices or modules in any combination The SLC is not restricted by any wire requirements and may be wired with any wire that complies with the NEC Loop Devices Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot Analog Photo Electric Smoke Heat Detector a smoke detector with a listed obscuration of 1.02 to percent obscuration and a fixed temperature 135 Fahrenheit heat detector Fixed Temperature Heat Detector that is selectable from 135 F to 185 Rate or Rise Heat Detector that has a fixed temperature selection from 135 and 174 and also will if the temperature increase 12 15 in one minute Duct Smoke Detector round base that is mounted to an electrical box and wired for connection of one of the above sensors round base that is mounted to an electrical box and wired for connection of one of the above sensors base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop Relay Base that contains two relays controlled by the SLC One relay is rated at 8 amps at 240 and the other is rated at 2 amps 240 VAC 30 VDC Sounder Base that contains an addressable sounder module that may be configured for local group all call The sounder follows the pattern sent to the device Contact Module provides a small foot print contact module for mounting inside an enclosure Action Addressable Pull Station Action Addressable Pull Station Contact Module is a standard contact module with an LED that mounts into a 4 square electrical box Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode Relay Module provides two form C relays that simultaneously active when the module is triggered by the panel Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC Output Module switches monitored power and is activated by the control panel Input Zone Module is used to connect conventional smoke detectors Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the Devices remote annunciator with a metal enclosure and key lock Character LCD Keypad remote annunciator with metal enclosure and key lock remote annucniator capable of displaying alarms supervisory and trouble status for 16 zones Amp Intelligent power supply Form C Relay Card Printer Card Optional Rack Mount Communications Bridge 1 may be added for remote IP Communicator Interface Module used in pairs to convert P Link over multimode fiber optional rack mount 2 OF 3 8830024 REV A11 13PRINTED IN USAPFC 6030FIRE ALARM CONTROL PANELfirealarmresources com Circuit Diagram or IP Receiver Monitoring Alarm Amp NAC Candela Strobe or Strobe Horn Candela or Strobe Horn Annunciator Device Enclosure Annunciator on P200 and Expander A Loop Base Detector Sounder Detector Heat Detector Base Detector Relay Detector Relay Output Contact Circuit Zone Detector Contact Contact Monoxide Station 3 OF 3 8830024 REV A11 13PRINTED IN USAPFC 6030FIRE ALARM CONTROL PANELfirealarmresources com