Potter PFC-6200 127 Expandable to 254 Points Addressable Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Features points expandable to 254 by use of one SLCE card Amp Power Supply NACs regulated rated at 3 amps each input output I O circuits for flexibility rated at 1 amp each synchronization for Potter AMSECO Gentex Cooper and System Sensor Software zones for versatile installation options x 40 LCD and keypad for ease of operation Detector Drift Compensation NFPA Compliant Smoke Sensitivity Test Built in Optional dual line digital alarm communicator reports by panel or point ID communication line for up to 31 accessories port for programming reporting and network system status reports and event information IP communicator supports report by point zone or panel W x H x D 17 5 8 x 26 x 3 3 4 Specs Mains amps 120 VAC 50 60Hz amps 240 VAC 50 60Hz mA Standby Alarm 7165 0328 0195 includes a 5 year warranty Fire Dept of Approval PFC 6200 is a single loop expandable to two loop analog addressable fire alarm control panel The panel utilizes the Potter Nohmi device that has a complete line of initiating and control devices The SLC is capable of 50 ohms of resistance and does not require the use twisted or shielded wire The on board Signaling Line Circuit SLC supports 127 of any combination of smoke sensors heat detectors or An additional SLC may be added in the control panel or remotely installed to provide an additional 127 points bringing the total capacity to 254 points panel has auto programming learn mode that will not affect the existing system when adding or deleting a device The system is capable 99 software zones cross zoning and counting zones The panel is fully programmed from a PC based software program that will work with XP Vista or Windows 7.0 operating systems PFC 6200 has an Ethernet connection for programming network connectivity and IP reporting communicator The system uses a simple cable for connecting a PC to the panel In addition the system may be connected to a building network and programmed while on the The system has a built in e mail function and will send system e mail reminders The IP communicator is listed with the Sur Gard III IP panel will support P Link devices which include the RA 6075 RA 6500 and LED 16 Annunciators RLY 5 Relay Module SPG 1000 Parallel Gateway printer card an FCB 1000 Remote Ethernet IP connection DRV 50 LED driver for 50 LEDs PSN 1000 Remote Supplies 10 Amp and FIB 1000 P Link Fiber Interface Module In addition the panel allows for the installation of the UD 1000 line telephone line digital alarm communicator transmitter DACT The UD 1000 is programmable for a single line or dual line and is with Ademco Contact ID or SIA DCS protocols SLCE 127 may be installed with 6,500 feet of the control panel and may be installed in the AE 8 eight slot or AE 14 fourteen slot expansion Another option is to install the SLCE 127 in the PSN 1000E intelligent power supply to allow remote installation of the loop adder and synchronized notification circuits Each PSN 1000 acts as a P Link repeater and will repeat the communication to allow the installation the remote loop thousands of feet from the main control panel complete system may be converted to Class A with a CA 6075 module The CA 6075 provides the hardware necessary to convert the annunciators through the Potter P Link connection protocol the NACs and the SLC to Class A operation Electric Signal Company LLC St Louis MO Cust Service 866 956 1211 Tech Support 866 240 1870 Canada 888 882 1833 www pottersignal com 1 OF 3 8830028 REV A11 13PRINTED IN USAPFC 6200FIRE ALARM CONTROL PANELfirealarmresources com Loop Accessories control panel may be connected with up to 254 addressable devices or modules in any combination The SLC is not restricted by any special requirements and may be wired with any wire that complies with the NEC Loop Devices Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot Analog Photo Electric Smoke Heat Detector a smoke detector with a listed obscuration of 1.02 to percent obscuration and a fixed temperature 135 Fahrenheit heat detector Fixed Temperature Heat Detector that is selectable from 135 F to 185 Rate or Rise Heat Detector that has a fixed temperature selection from 135 and 174 and also will if the temperature increase 12 15 in one minute Duct Smoke Detector round base that is mounted to an electrical box and wired for connection of one of the above sensors round base that is mounted to an electrical box and wired for connection of one of the above sensors base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop Relay Base that contains two relays controlled by the SLC One relay is rated at 8 amps at 240 and the other is rated at 2 amps 240 VAC 30 VDC Sounder Base that contains an addressable sounder module that may be configured for local group all call The sounder follows the pattern sent to the device Contact Module provides a small foot print contact module for mounting inside an enclosure Action Addressable Pull Station Action Addressable Pull Station Contact Module is a standard contact module with an LED that mounts into a 4 square electrical box Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode Relay Module provides two form C relays that simultaneously active when the module is triggered by the panel Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC Output Module switches monitored power and is activated by the control panel Input Zone Module is used to connect conventional smoke detectors Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the Devices 31 devices max depending on modules LCD keypad remote annunciator with a metal back box and key lock LCD keypad remote annunciator with a metal back box and key lock Analog Addressable loop expansion module 10 Amp intelligent power supply P Link repeater with enclosure for SLCE 127 Amp intelligent power supply P Link repeater 2 OF 3 8830028 REV A11 13PRINTED IN USAPFC 6200FIRE ALARM CONTROL PANELfirealarmresources com Circuit Diagram Communicator Monitoring NAC circuits Amp each Candela Strobe or Strobe Horn Candela or Strobe Horn Alarm Communicator Annunciator Annunciator 1000 E Supply Line Expander A Input Output Circuits SLCE 127 system Loop Base Detector Sounder Detector Heat Detector Base Detector Relay Detector Relay Output Contact Circuit Contact Contact Station Zone Detector Monoxide 3 OF 3 8830028 REV A11 13PRINTED IN USAPFC 6200FIRE ALARM CONTROL PANELfirealarmresources com

Related Files