PTS C TYPE SWITCH and CUL Listed FM Approved CSFM Listed NYMEA Accepted 7 L x 3.75 W x 3 D including bracket 13.6 oz 385,5 g Non Corrosive Composite Material Limitations cm x 9,5 cm x 7,6 cm NEMA Temperature Cover Tamper Activated by housing cover removal Ratings SPDT Plug Contacts 100 mA at 28 VDC AC mA at 12 VDC AC 2 wire 18 Ga Waterproof Approx 8 2,43m long so the plug must be pulled from the housing when the valve is Cut off excess cable and terminate on the plug terminals of the board Do not leave more than 2 50mm of excess wiring in the Dress wires to outside edge of housing so as not to interfere cover tamper cover tamper switch can be wired into the plug circuit or wired as separate circuit See wiring diagrams PTS C and its associated protective monitoring system should be in accordance with applicable NFPA codes and standards and or authority having jurisdiction manufacturer recommends quarterly sure valve is fully open before restoring PTS C Installation Non rising Stem Valve number 1010201 Model PTS C is designed to supervise sprinkler system control and may also be used to secure gates and other applications This is particularly useful for unusual conditions such as non rising valves 6P enclosure allows the device to be mounted outdoors even virtually eliminates contact corrosion the valve wheel will pull the plug out of the receptacle The plug be reinserted after operation until the plug receptacle cover is with the special hex key provided This key should be left with building owner or responsible party Replacement or additional cover screws and hex keys are available For cover tamper screws order no 5490344 For hex key order stock no 5250062 plug into housing take the loose end of the cable and loop it the valve handle and into the housing Adjust the length of Stipulated By Factory Mutual And Underwriters Laboratories unit is not intended or designed for ordinary use It is a application device to be used for unusual conditions such non rising stem gate valves where no other approved or listed of protection is available or practical As this unit does meet NFPA codes and standards requiring restoration signal the valve is positioned to normal special attention should be by the responsible parties to assure that the proper operation this device is maintained This device should only be restored to when the valve is in the normal condition Electric Signal Company 100 Westmore Drive Units 6 7 Etobicoke Ontario M9V 5C3 Phone 888 www pottersignal com IN USA 8900253 REV B 4 07 1 OF 4 Diagrams And Cover Tamper Wired To Same Circuit Single Device Multiple Devices C TYPE SWITCH And Cover Tamper Wired To Separate Circuits Single Device Multiple Devices IN USA 8900253 REV B 4 07 2 OF 4 C TYPE SWITCH aupr de Underwriters Laboratories de Laboratoires des du Canada et du commissaire des incendies de l de la CSFM approuv par le CSI et la NYMEA 7 po Long x 3,75 po L x 3 po P incluant le support 13,6 onces 385,5 g Mat composites non corrosifs environnementales cm x 9,5 cm x 7,6 cm Bo des raccords appropri sont utilis IP67 Plage anti sabotage du compartiment en retirant le couvercle des contacts des bouchons des SPDT mA 28 volts c c c a mA 12 volts c c c a Bi la poign du robinet puis dans le compartiment Ajuster la longueur branchement aux bornes de la carte de circuits imprim Ne pas laisser de 2 po 50 mm de c dans le compartiment Fixer les c la sabotage commutateur du couvercle anti sabotage peut branch au circuit du ou en tant que circuit s Voir les sch de c PTS C et son syst de surveillance et de protection associ doivent ou plus fr que le robinet est compl ouvert avant de le PTS C dans d applications Cette unit est utilis surtout dans des non montante des endroits pouvant inond comme les puits et les foss La tige du commutateur emp la corrosion au niveau des contacts est possible de sortir le bouchon de son socle en tournant le volant manoeuvre Le bouchon ne peut r qu avoir retir couvercle du socle l de la cl hexagonale sp fournie cl doit remise au propri du b ou au responsable est possible de se procurer des vis inviolables et des cl hexagonales ou de rechange Pour les vis inviolables commander

Related Files