Potter PVX-100M 200M Mass Notification System

File Preview
File Preview
Click below to download for free

File Data

Name potter-pvx-100m-200m-mass-notification-system-8039472615.pdf
Type PDF
Size 971.04 KB
Downloads

Text Preview

Features 100W or 200W Mass Notification System Expandable to 2000W Listed to UL864 UL2572 Digitally Recorded EVAC MNS Messages Tones Live Microphone Override of Message and Tones 25 or 70 VRMS Field Selectable Up to 30 LOCs Optional Switch Zone Inputs Output cards 120VAC Power Supply and Battery Charger Backup Amplification Option Easy Installation and Operation High Quality Voice Recordings Built in Alarm and Alert Signals Compatible with 12 24VDC Fire Alarms Panels 3 Minute Message Restart on Microphone Key Made in the USA Product includes 5 year warranty PVX 100 200M ACU provides a Mass Notification System maximum flexibility to meet the needs of almost any application PVX 100M contains one 1 100 Watt amplifier while the PVX contains two 2 100 Watt amplifiers 100 200M can operate as a standalone system or tie into a fire control panel where fire and MNS are required Separate output make dual strobe control simple Optional cards allow for message input and output control enable systems to have up to 30 remote control locations Any in the system is available at the Primary ACU or the LOC Specifications Power Battery Power Output Dimensions WxHxD Watts 25 70 VRMS Tone 2a Standby Alarm Voice x 27 x 4 standard Grey optional page 1 OF 2 REV B 12 19Potter Electric Signal Company LLC St Louis MO Tech Support 866 956 1211 Customer Service 866 572 3005 www pottersignal comPVX 100M 200MMass Notification Systemfirealarmresources com Options PVX RM16 Local Operating Console LOC MIC with Switch Control Active Fault LED Flashes Green to indicate communication steady Amber to indicate Fault In Use LED Indicate Red to show lockout Remote Mic is locked out if any other MIC is In Use When the In Use MIC releases PTT the Remote MIC will be able Page Primary MIC in the EVAX 100M will always have highest priority and be able to override any Remote MIC Switch LED Card 8 SPDT Momentary Switches and Tri Color LEDs Switches can be programmed for Message Activation Paging or Control Switch LEDs will steady green on message activation red on page alarm and amber on fault with associated speaker circuit Input LED Card 8 Input points and red LEDs Inputs are activated by external dry contact closure Inputs may be programmed for message activation or control activation the corresponding input LED will indicate Output LED Card 8 Output points and red LEDs Outputs are solid state N O dry contacts rated at 30mA 24V Alternately outputs may be tied to a voltage input feed that voltage out as a drive point Outputs can be programmed to follow message activation page or control On activation the corresponding will indicate Number Number 200M Mass Notification Systems 100M 12Z 200M 12Z ACU in cabinet with 8 switches 4 Class B Spkr Circuits ACU in cabinet with 8 switches 8 Class B Spkr Circuits ACU in cabinet with 8 switches 12 Class B Spkr Circuits ACU in Cabinet with 8 switches 16 Class B Spkr Circuits ACU in cabinet with 8 switches 8 Class B Spkr Circuits ACU in cabinet with 8 switches 12 Class B Spkr Circuits ACU in Cabinet with 8 switches 16 Class B Spkr Circuits Notification System Accessories MIC LOC with 8 switches MIC LOC with 16 switches Module 4 Class B 2 Class A Spkr Circuits LED 8 Switches card 1 included with PVX 100M 200M 8 Input card LED 8 Output card Specifications Voice Evacuation System shall be Potter System Series PVX 100M or approved equal The Voice Evacuation System shall provide 100 watts of power and 100 watts of voice power and all be listed to UL864 and UL2572 All speaker circuits shall be field selectable for 25 or 70 Vrms and shall be power limited The Mass Notification System shall be micro processor based and shall contain an integral microphone 100 Watt amplifier tone generator digital message repeater 120VAC power supply and battery charger The Potter MNS message signal shall be broadcast until reset manually or by a FACP Silence Reset An option for a 10 minute timeout must be provided Emergency personnel may interrupt broadcast with a manual page On reset the system shall automatically return to standby normal operating condition System must have capacity a minimum of 16 messages Messages may be activated by either manual control or by automatic input from either the FACP or from any normally contact device Remote paging microphone s will be supported by the system and be capable of switch control page zones messages or control Remote microphone s may be mounted up to 3000 feet from the system and be fully supervised System must be capable of supporting up to Remote Microphones page 2 OF 2 8830070 REV B 12 19Potter Electric Signal Company LLC St Louis MO Tech Support 866 956 1211 Customer Service 866 572 3005 www pottersignal comPVX 100M 200MMass Notification Systemfirealarmresources com

Related Files