Potter TRM-4 Twin Relay Module

File Preview
File Preview
Click below to download for free

File Data

Name potter-trm-4-twin-relay-module-9876543201.pdf
Type PDF
Size 1.71 MB
Downloads

Text Preview

TRM 4 Relay Module Two 2 Isolated Sets of Form C Contacts Powered directly from 2 wire SLC loop No additional power required SLC Class A Style 6,7 Class B Style4 Mounts on a standard 4 or double gang box Wiring terminals accessible when mounted in box Wiring terminals accept 22 to 14 AWG Product includes a 5 year warranty Number 1430824 TRM 4 is compatible with Potter PFC 6000 series and PFC addressable re alarm control panels The TRM 4 is a relay that is programmed to activate in correlation with initiating such as detectors and pull stations The TRM 4 can be used applications such as elevator recall AHU shutdown or where purpose relays are needed The TRM 4 module uses one 1 address on an SLC Loop The has two 2 Isolated Form C relay contacts that transfer when the device is activated The TRM 4 module one red LED that ashes when the device is being polled by control panel Speci cations Voltage SLC Standby Current SLC Alarm Current Output Style Rating Resistive Tempurature Range Humidity Range no of Modules per Loop 2 Form C 24 VDC 0.5A 125VAC to 120 0 to 49 to 93 non condensing units 106mm L 4.17 1.14 29mm 4 Square or Gang Box lbs Options Weight Electric Signal Company LLC St Louis MO Tech Support 866 956 0988 Customer Service 866 572 3005 www pottersignal com REV D 7 14 PAGE 1 OF 2 the Address SLC device must be assigned an address prior to installation The address is set using either the hand held device programmer or the addressing feature the PFC 6000 PFC 8500 Series control panels connecting a device to the SLC loop take the following precautions to prevent potential damage to the panel or device Power to the device is removed Field wiring is correctly installed Field wiring has no open or short circuits Using Compatible Electrical Box Diagram FACP or Previous Module Loop Next Module 1 2 Open Closed NO1 NO2 NC1 NC2 Rating 2.0A 5A Relay Module No TRM 4 Open 1 1 Closed 1 Open 2 2 Closed 2 593 17 is possible that the relay contacts on the TRM 4 may be shipped the non normal activated state To ensure that the internal relays set to the normal state connect the module to the SLC loop and the control panel before terminating the wiring to the dry relay PAGE 2 OF 2 REV D 7 14Potter Electric Signal Company LLC St Louis MO Tech Support 866 956 0988 Customer Service 866 572 3005 www pottersignal comTRM 4Twin Relay Modulefirealarmresources com

Related Files