Cerberus Pyrotronics ADB-3 ADBI-60 Audible Bases 6163

File Preview
File Preview
Click below to download for free

File Data

Name cerberus-pyrotronics-adb-3-adbi-60-audible-bases-6163-2670983514.pdf
Type PDF
Size 893.76 KB
Downloads

Text Preview

Audible Bases AND ARCHITECT SPECIFICATIONS ADB 3 ADBI 60 ADB 3 ADBI 60 ADB 3 Compatible with Series Detectors ADBI 60 Compatible with Series Detectors Produces 85db Audible Signal Surface Mounting Listed NYMEA Approved ADB 3 and ADBI 60 audible bases contain a prewired piezo electric device that produces an 85db signal localized annunciation The ADB 3 is designed to be with conventional Series 3 plug in detectors The is designed for use with addressable analog intelligent Series plug in detectors Typical applica includes all areas that normally would require localized annunciation such as hotel motel apartment and dormitory rooms The ADB 3 and ADBI are UL listed and NYMEA approved ADB 3 is powered by a conventional zone of the control panel with operation of the piezo electric being controlled via terminal 6 of the detector During the supervision or no alarm condition circuit to the ADB 3 is absent and there is zero current Upon alarm of its detector circuit ground is provided the ADB 3 via the base contact of terminal 6 and the device is activated producing an 85db audible which serves as the local alarm ADB 3 is turned off by the reset of the system control The system guarantees that only one auxiliary or device will activate per zone ADB 3 operates with an input zone power of 18 VDC VDC and requires a 4 square 2 deep electrical box The ADB 3 is not to be used for primary evacuation but only as a audible signal device Audible Base Model ADBI 60 consists of a standard Pyrotronics Series 3 base combined with sup circuitry for the and Series Detectors and an device All field wiring terminates at two of the four terminal blocks located on the back of the unit ADBI 60 can be used with the MXL MXL IQ or IXL different configurations can provide audible signal power to the ADBI 60 at terminals 1 through 4 as in diagrams 2 3 4 and 5 See the typical Installa Diagram Section During the supervision state alarms the polarity of the power to all ADBI 60 is in normal state resulting in zero current flow to base NUMBER Catalog Number 6148 any alarm is reported to the system the power to all reverses polarity but no audible sounds The may then selectively command the ADBI 60 under control to become audible All ADBI 60 are capable of sounding simultaneously individually in any combination depending upon the system Pro and control panel The ADBI 60 is UL 268 listed and the audibility sound output of 85 decibels at ten The ADBI 60 is not to be used for primary evacuation but only as a audible signal device Data Data ADB 3 is fully compatible with Series 3 plug in detec When an ADB 3 is used with a compatible detector remote relay or lamp device can be used with that detector No more than thirty 30 compatible of any type or combination other than thermals manual stations may be used on any one Cerberus conventional system detector circuit ADBI 60 is compatible only with Cerberus Pyrotronics or IXL addressable detectors No more than sixty 60 Series detectors on MXL or IXL loops may be used on one addressable initiating circuit smoke detectors used with the ADB 3 and ADBI 60 subject to the maximum 30 ft center spacing 900 sq as referred to in the National Fire Protection Association 72 This spacing however is based on ideal namely smooth ceiling no air movement and physical obstructions between the fire source and the This spacing should be used as a guide or in detector installation layout Do not mount in areas close to ventilating or air conditioning Exposed joists or beamed ceilings may also effect spacing limitations for detectors It is mandatory that 72 and good engineering judgement be applied detector locations and spacing Specifications Specifications audible device that shall be used for localized annun shall be contained in a plug in twist lock detector that is compatible with Cerberus Pyrotronics Series plug in detectors The detector base shall a prewired piezo electric device that will produce audible signal at a minimum of 85 db at 10 feet audible device when used with a standard Cerberus conventional zone fire alarm system shall be ADB 3 Power shall be provided to the ADB 3 audible through the zone wires of the fire alarm control panel input power provided shall be 18 VDC 24 VDC The alarm panel shall guarantee that one audible base ADB 3 or one remote relay model RR 3 3S or one lamp model RL 30 or RL 40 will activate per zone activated the ADB 3 shall be silenced via the reset of control panel audible device when used with the addressable Cerberus Pyrotronics fire alarm MXL or IXL Sys shall be the ADBI 60 Power shall be provided to the by the system if the total power requirement is than 3.0 amps or from a separate auxiliary power if the total power requirement exceeds 3.0 amps of all audible bases shall be capable of sounding individually or in any combination Once the audible base shall lock into alarm and must silenced at the MXL or IXL System control panel or optional printer The audible base when used with Cerberus Pyrotronics addressable analog System MXL IXL shall require input power of 28 48 VDC peak or 20 27 VDC while on battery audible bases shall be UL listed Specifications Specifications and ADBI 60 Ouput ADB 3 Rating 10 ft min ADBI 60 Rating Zone Power 18 24 VDC 0 A 13 mA at 25 VDC one device is guaranteed activate per zone AC Power 28 48 VDC peak wave Battery 20 27 VDC 0 A 37 mA at 25 VDC The maximum number of ADBI 60 per a AA 30U ICP MMB 1 CES or CSM 4 Bell power loop is with no other devices connected and with the loop current available The number of ADBI 60 cannot exceed the current available to the loop See the IXL P N 315 092371 or the MXL Manual P N 315 for the compatibility details of ICon ALD and circuit wiring Maximum line resistance permitted both wires not the end of the line resistor is 3 ohms A of 14 AWG wire must be used T tapping of the audible circuit Diagrams 2 3 4 and 5 not allowed The 24 VDC external power source should not powering any other devices that could generate on the line such as a Voice Alarm system or which are not part of the fire alarm system If is any ground detection with the 24 VDC external disconnect it Use the AA 30U for either Class A or Class B wiring the for Class B wiring only Diagrams 2 and 3 If the ADBI 60 is powered by MXL Diagrams 4 and 5 total system power available for indicating appli is 3A If more than 3A is required use the in Diagram 2 or Diagram 3 for auxiliary Connect terminal 6 of the PS 35 Diagrams 2 and 3 the minus DC side of the MXL main power supply for ground fault supervision Each audible base is marked to indicate its type or ADB 3 ADBI 60 ADB 3 boxes are usually marked with a check mark if the audible portion of an ADBI 60 is for reverse polarity detection the unit is with an S If it is not marked with an S the portion of the unit does not have reverse detection In either case each unit must be for proper operation Base and Detector Compatibility ADB 3 With System 3 ADBI 60 With MXL or IXL Information Information Detector Base for 3 Audible Detector Base for and MXL Interface Module Class A Alarm Extender Class B Alarm Extender Charger Supply Module Addressable Intelligent Module Mounting Plate for TRI 2R

Related Files