Cerberus Pyrotronics CZI Series Collective Zone Interface Modules 9358

File Preview
File Preview
Click below to download for free

Text Preview

CZI Series Collective Zone Interface Modules AND ARCHITECT SPECIFICATIONS CZI H2S CZI H4S CZI L2S and CZI L4S Monitors Conventional 2 Wire Smoke and Normally Open Initiating Surface or Flush Mounting Each Module is Address Programmable Field Programmable Built in LED Indicator LED Pulses Indicating Connection to Communication Line Requires no DIP Switch Programming Screw Terminals Provided No Auxiliary Power Supply Required Listed ULC Listed FM CSFM and NYMEA Approved Pyrotronics CZI Series Collective Zone Interface are used to connect initiating devices to the IXL initiating circuits are capable of supporting conven 2 wire type detectors as well as contact type while CZI L initiating circuits support contact type only Associated with each CZI is an LED that both normal and alarm status CZI are available either 2 or 4 wire initiating device circuits and for surface or flush mounting and Architect Specifications Zone Interface CZI Series models shall be for supporting conventional initiating devices Series shall support both detectors and direct initiating devices CZI L Series shall support direct initiating devices only CZI shall incorporate an pulsing LED for confirmation that the CZI is active LED shall change from pulsing to steady state upon alarm condition for quick identification of the alarming Collective Zone Interface Module electronics are to monitor the initiating device wiring for trouble alarms In its quiescent mode of operation each Zone Interface displays a pulsing LED indicat quiescent operation of the zone and proper connection the Network Communication Line the Collective Zone Interface is in an alarm condi the interface reports the alarm condition to the Control At the same time the status of the zone is reported the Control Panel the LED will be lit continuously and state of the zone non latching monitored loop requires input device becomes latched until the interface a reset command from the Control Panel Once reset command is received the CZI will resume its mode of operation its trouble mode of operation each CZI displays a LED indicating quiescent or active operation of the If the trouble signal is derived from the improper to the Network Communication Line then the will not flash normally NUMBER of the CZI must be performed when a new is installed on a system In order to program a CZI the Panel must be placed in the programming mode the address will be assigned to the CZI that has the tool applied to it The circuit must also be to the specific application of the device and being driven within the CZI loop should be installed in accessible locations for purposes They should be mounted in visible so that their LED may be seen for quick status Diagram and Environmental VDC from Network Power Power Line Temperature Temperature 0 to 49 Humidity Humidity non condensing is a 43 4 x 43 4 x 15 8 Trim is 53 4 x 53 4 x 1 2 deep 411 16 sq device box Box Box CZI H Detectors Series Series Series Beam Detector driven options not compatible with CZI Information No No Only 2 wire Collective Zone Interface Class B Only 4 wire Collective Zone Interface Class A Current 2 wire Collective Zone Interface Class B Current 4 wire Collective Zone Interface Class A trim ring for CZI and CE S tool The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics control equipment will be considered a misapplication of Pyrotronics equipment and as such void all warranties either expressed or implied with regard to loss damage liabilities and or service problems Pyrotronics Ridgedale Ave Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 3 94

Related Files