Cerberus Pyrotronics DI-6 Adjustable Ionization Smoke Detector 6126
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-di-6-adjustable-ionization-smoke-detector-6126-7539162840.pdf |
---|---|
Type | |
Size | 1.07 MB |
Downloads |
Text Preview
Adjustable Ionization Detector AND ARCHITECT SPECIFICATIONS DI 6 DI 6 Adjustable Sensitivity Two Response Settings Adjustable Smoke Inlet Twist Lock Base with Intergral Lamp Usable in Air Currents Up to ft min Encapsulated Electronics 268 Listed ULC Listed Cerberus Pyrotronics DI 6 adjustable ionization smoke is uniquely designed and is the most advanced most flexible UL 268 listed ionization smoke detector the market today DI 6 inherent adjustable characteristics allow for 8 combinations of 3 adjustable settings adjustable adjustable smoke entry ports and two 2 time settings DI 6 design permits it to detect a full range of visible invisible smoke particles therefore allowing it to detect before serious damage is caused ability to detect the first traces of fire along with the flexibility makes it suitable for use in a wide of commercial industrial and institutional fire and extinguishing applications Description DI 6 detector is a plug in dual chamber ionization is a plug in dual chamber ionization detector with adjustable sensitivity field adjustable smoke inlets two 2 response time settings heart of the DI 6 is its sensor which is made up of two chambers The first chamber the sampling is open to the surrounding air and detects the of combustion products The second chamber reference chamber is virtually sealed and serves as a to stabilize the detectors sensitivity for changes environmental temperature humidity and pressure products of combustion enter the sampling chamber chamber current is reduced At the time the voltage exceeds the predetermined threshold an alarm is to the control unit the alarm is signalled to the control unit it is locked until it is reset at the control panel NUMBER DI 6 has two levels of sensitivity low and high which easily set by rotating a ring at the top of the detector a pointed tool at the low position the detector raises the alarm requiring more particles of combustion to initiate alarm therefore making the detector less sensitive The is true for the high sensitivity setting are two time response settings for the DI 6 The setting is set by placing the blue marker inside the and the delay setting typically 30 seconds is set placing the blue marker on the outside of the detector making it clearly visible order to adapt the detector to dusty environments and air currents up to 1000 feet per minute the DI 6 two 2 settings for the air shields protecting the inlets inlet is adjusted by moving the grill of the detector with vent tool part number 545 485624 Applications Conditions table on page 3 depicts the detector settings in relation to various applica and ambient conditions DI 6 with Series 4 Base operates on 18 24 VDC by the Cerberus Pyrotronics control system and a 2 wire detector circuit using 18 AWG wire detector can be either flush of surface mounted using DB 4TS base for surface mounting and model DB for flush mounting Both bases have an integral alarm and a terminal connection for using a remote alarm model RLI1 2 RL 30 RL 40 or a remote relay model The model RR 2 relay has one set of double pole throw contracts rated at 120 VAC 2 amp resistive the RR 2 is used and the relay control function is no more than one 1 DI 6 should be installed in a circuit or zone and no other initiating devices be installed in that same circuit or zone An excep to this rule would be an application where a number of relays were used each of which was connected to same critical control function detector can be locked into the DB 4TS base with the field installed locking mechanism model DB LK sensitivity of the detector can be checked in the field the use of the MG 7 9 sensitivity tester Data more than thirty 30 detectors of the ionization or type may be used on any one Cerberus detector circuit An unlimited number of or manual stations may be used or added to one The number of flame detectors used in combination ionization and photoelectric detectors would be to the power consumption of that particular model detector DI 6 is applicable to the 30 foot center spacing 900 ft as referred to in the National Fire Protection Asso Standard 72 This spacing however is based on conditions namely smooth ceiling no air movement no physical obstructions between the fire source and detector This spacing should be used as a guide or point in detector installation layout Do not mount in areas close to ventilating or air conditioning Exposed joists or beamed ceilings may also affect spacing limitations for detectors is mandatory that engineering judgement be applied detector location and spacing Refer to the supplied with each detector or contact your Pyrotronics regional office for more detailed and Architect Specifications fire detector shall be plug in ionization type detector Pyrotronics model DI 6 detector shall be made up of two 2 ionization cham one sampling chamber to detect the presence of of combustion and one reference chamber to the detectors sensitivity for changes in environ temperature humidity and pressure detector shall have adjustable sensitivity two posi high and low which can be changed without the of special tools detector shall have two 2 response times normal and nominal 30 seconds detector shall be able to be used in varying air cur up to 1000 feet per minute detector shall have a two 2 position smoke inlet grill base assembly into which the detector is installed be of the twist lock variety and shall be Cerberus DB 4TF or DB 4TS Pigtails or on line connec shall not be permitted The base shall include a LED to alarm of the detector is possible to connect either a remote lamp model RL 30 RL 40 or a remote relay model RR 2 to the base assem The relay shall contain a set of DPDT contacts rated at 60Hz 2 amp resistive for the control of external security base lock model DB LK shall be installed in areas where tamper resistant installation is required detector shall be capable of having its sensitivity in the field using the MG 7 9 sensitivity tester detector or group of detectors shall require a two wire of 18 AWG thermoplastic fixture wire enclosed in or 18 AWG limited energy shielded cable without if permitted by local codes Characteristics VDC Voltage microamps Current Current milliamps Temperature per UL 268 Velocity per UL 268 0 1000 ft min characteristics UL 268 0 93 non condensating 0 to 100 38 Top 2.56 Bottom ft used with Series 4 Base Information 7 9 ionization with adjustable air vents response time assembly with alarm lamp and for remote relay or lamp surface includes adapter for 4 box assembly with alarm lamp and for remote relay or lamp flush includes adapter for 4 box Lock for DB 4TS Relay Alarm Lamp Tester lb 45 kg lb 45 kg lb 45 kg lb 45 kg lb 45 kg lb 45 kg Setting Table Data Wiring Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 8 94