Cerberus Pyrotronics EL-410D Voice Alarm System Supply Amplifier Unit
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-el-410d-voice-alarm-system-supply-amplifier-unit-4259371608.pdf |
---|---|
Type | |
Size | 1.02 MB |
Downloads |
Text Preview
EL 410D Alarm System Amplifier Unit AND ARCHITECT SPECIFICATIONS 100 Watt Output 25 Volt or 70 Volt Operation Power Failure Indicator Battery Supervision Battery Transfer ULC Listed and CSFM Model EL 410D is the amplifier unit for the MXLV Voice System The audio output amplifier section is at 100 watts 70.7 VRMS or 25 VRMS The amplifier designed to automatically switch over to battery opera upon failure of the 120 VAC input Power and battery LED are provided The unit mounts in the MME 3 MLE 6 MXL system enclosures using the MSR 1 Rail Kit The unit also mounts within a standard 3 enclosure and occupies eight regular spaces Model EL 410D operates from a 120 volt 60 Hz supply a 24 volt battery standby or other emergency DC Loss of the main operating power transfers the to battery operation and is signaled by an LED on amplifier Restoration of main power automatically the system to normal condition Supervision battery is supervised for charge voltage condi Shorts or open battery lines will be signaled by an at the amplifier amplifier and the power lines are protected by fuses are all supervised and Architect Specifications amplifier unit shall be a Cerberus Pyrotronics Model It shall supply up to 100 watts of audio power at 25 or 70 VRMS It shall operate from a 120 VAC 60 power supply and have provision for battery standby of the main power supply shall transfer the unit to operation and shall indicate such loss visually at amplifier The system shall return to normal operation upon restoration of the main supply voltage NUMBER amplifier and all the DC lines shall be protected by The amplifier shall remain supervised during battery with a standby drain of less than 200 mA The shall be capable of being surface or flush mounted in approved wall mounted enclosure Line and Fuse Rating Supply Circuit Breaker Fuse Power Data Requirement Battery Drain Supervision 100 watt Output Output Response Sensitivity 60 Hz 2.5 Amp Volt mA Amp or 70.7 Volts 100 RMS less than 1 at 1KHz Hz 1 dB V RMS Amp AGC Amp AGC Amp AGC Amp AGC in 22.9 cm H x 19 cm W x 41 2 in cm for rail in a flush or wall mounted Information No Wt Kg Unit Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 Issue