FM 200TM Storage Container ENGINEER AND ARCHITECT SPECIFICATIONS FM 350 FM 500 High Flow Rate Valve Manual Electric or Pressure Operated Optional Liquid Level Indicator at Factory to 350 or 500 lbs FM 200TM in 1 lb Increments Listed Approved Cerberus Pyrotronics Model FM 350 and FM 500 are capacity FM 200TM storage containers with 2 inch valves The FM 350 and FM 500 have a capacity 350 or 500 lbs of FM 200TM The FM 350 and FM 500 are of local or remote manual operation electric pneumatic operation or a combination of a and pneumatic operation The FM 350 and FM 500 assemblies are designed to meet the requirements UL 1058 and are ideally suited for use in all large com and industrial hazards Description FM 350 and FM 500 can be filled with a maximum of or 500 lbs of FM 200TM and pressurized with nitrogen 360 psig at 70 cylinders are operated by the relief of pressure above valve piston which permits the valve piston to travel thus fully opening the valve and permitting the FM to discharge through the outlet which is located at top of the valve FM 350 and FM 500 can be actuated by one of the means Electric Solenoid Valve The solenoid valve is closed and opens upon electric energy being thus relieving the pressure above the valve piston causing the cylinder valve to open The solenoid valve a swivel nut for a mechanical connection to the cylinder For electrical connection it is furnished with 18 inch which are fed through flexible metallic conduit to convenient removal of the solenoid valve from the valve when servicing Local Manual Control Head moving the actuat lever through 90 causes a pin to depress and open the check on the valve and releases FM 200TM pressure the valve piston Remote Manual Control Head Same Actuation the local manual except the lever is controlled by a 1 16 diameter stainless steel pull cable enclosed in inch with corner pulleys at each change of direction The terminates in a remotely located pull box Pressure Actuator The pressure actuator replaces local and remote control heads on the valve It contains piston of sufficient area to provide the necessary force to the pilot check when pressure from the FM 200TM of a master cylinder is applied through 5 16 inch NUMBER Cylinder Features and Valve Assembly 350 lb 158.7 kg Model FM 350 FM 350L and Valve Assembly 600 lb 272.1 kg Model FM 500 FM 500L The safety cap be installed all times except the cylinders connected to system piping being filled The cap must be removed its chain The safety cap be installed all times except the cylinders connected to system piping being filled The cap must be removed its chain tubing or 5 16 inch actuation hose The pressure is used on pressure operated slave cylinders are to be released simultaneously with the control cylinder master cylinder can be used to pressure operate up to maximum of four slave cylinders If more than five cylin are required up to 15 may be pressure operated using nitrogen pilot cylinder cylinder valves have a pressure actuation outlet port is under pressure only while the valve is discharging port has a 1 8 inch pipe thread and is fitted with a pipe which is removed when the port is to be used and with a master cylinder adapter kit The tubing or hose is connected to the adapter kit and run to pressure actuators on the slave cylinders pressure operating tubing in a multi cylinder fire system can be supervised with the use of the CSS cylinder supervisory switch Combination Pressure Actuator and Manual A special pressure actuator is also available to either a local or remote type manual control head be attached It is used when both pressure actuation manual control is required for the same cylinder steel cylinders are manufactured and tested in with D O T specifications 4BW500 The FM and 500 lb cylinders are fitted with 2 lifting lugs for of handling 2 inch brass discharge valve can be piped or to the piping or manifold via the 2 inch flexible hose bracketing expressly designed for the FM 200TM is available for mounting directly onto a wall or with mounting channels FM 500L 350L and 200L comes equipped with a liquid indicator for easy determination of the weight of the in the cylinder Specification FM 200TM storage container shall be capable of 350 or 500 lbs of FM 200TM and be pressurized nitrogen at 360 psig at 70 FM 200TM cylinders shall be operated by the relief of above the valve piston The valve shall be actu by local or remote manual operation electric opera pneumatic operation or as combination of a manual pneumatic operation pneumatically operated systems one master cylinder be capable of operating up to 4 slave cylinders if desired the pressure operated multi FM 350 or FM 500 fire extinguishing system shall be supervised by model CSS Cylinder Pressure Supervisory Switch system shall be capable of either being piped or to piping via a 2 inch flexible discharge hose desired the FM 200TM container shall come equipped with liquid level indicator to determine the weight of FM 200TM the container FM 200TM container and system shall be listed by Laboratories and approved by Factory Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1996 sheet dated 9

Related Files