Cerberus Pyrotronics MOM-2 Network Option Module Cardcage 5043

File Preview
File Preview
Click below to download for free

Text Preview

MOM 2 Option Module Cardcage AND ARCHITECT SPECIFICATIONS Two Half Width or One Full Width Option Slots Clamp Type Screw Terminals for Field Connections Mounts in MXL Main Cabinet MXL IQ MXLR Remote Units or MXL SS Provides Input Terminals for Auxiliary DC Accepts CRM 4 CZM 4 ALD 2I CSM 4 CMI 300 REP 1 NIM 1R and XLD 1 Listed ULC Listed CSFM NYMEA FM and City of Chicago Approved MOM 2 cardcage provides the MXL main unit or units with card slots for option modules Each supplies connection space for either one full width module ALD 2I CZM 4 NIM 1R XLD 1 or two option modules CSM 4 CRM 4 CMI 300 NET 7 Note only one CMI 300 may be used per system Modules are supplied with card guides MOM 2 also provides a means of connecting the modules to the MXL network It routes 24V unfil DC and 5 VDC to power the option The DC is routed to the MOM 2 from the MMB 1 board or the PSR 1 network supply terminals are mounted on the MOM 2 to provide access for field wiring connections Screw terminals also provided for connection to an auxiliary power for use with CSM 4 indicating circuits when audible visual power is required MOM 2 mounts in one of the MXL system back boxes at the main MXL MXLR remote units or MXL mini One MOM 2 may be mounted horizontally in MSE mini enclosure equipment is approved for operation over the tem range of 0 and 49 and Architect Specifications between optional circuit cards and the MXL network shall be provided by a MOM 2 expansion The MOM 2 shall provide one full width edge type plug in slots for the addition of the follow system option card modules CZM 4 conventional module CRM 4 controllable relay module CSM 4 signal module XLD 1 Series Device ALD 2I analog loop driver module CMI 300 CXL NIM 1R network interface module REP 1 repeater ALD 2I NIM 1R and the CZM 4 shall each one full slot in the MOM 2 and REP 1 CRM 4 CSM 4 and CMI 300 shall each occupy one half in the MOM 2 MOM 2 shall also provide a distribution point for module power The MOM 2 shall supply necessary terminal connections for any option module field This shall allow the replacement of modules without removal of field wiring MOM 2 shall be mounted in one of the MXL system located at the main MXL unit or MXLR remote or MXL mini enclosures NUMBER MXL Modules Information Number Number Module Cardcage Instructions Ckt Module Module Zone Module Interface Module Module Interface Module Loop Driver Diagram Series Interface Module Diagrams the MOM 2 in an MBR 2 Backbox the MOM 2 in an MSE Enclosure Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1996 sheet dated 3 95

Related Files