Cerberus Pyrotronics MS Series Manual Fire Alarm Station 6183
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-ms-series-manual-fire-alarm-station-6183-5723610984.pdf |
---|---|
Type | |
Size | 1.05 MB |
Downloads |
Text Preview
ENGINEER AND ARCHITECT SPECIFICATIONS ACTION ACTION SERIES Fire Alarm Boxes Durable Plastic Design Shock and Vibration Resistant Activation Visibly Noticeable Optional Contact Arrangements Options Include Keyswitch or Alarm Lamp No Break Rods Necessary Surface or Semi flush Installation Listed FM and CSFM Approved Cerberus Pyrotronics Single and Double Action Manual Fire Boxes have been designed with extreme flexibility in mind meet a wide variety of application requirements and operation boxes are available with two different operating modes being a simple single action function utilizing a action The cover locks in the down position until the box is the double action manual boxes except for the MS 501 of the dual actions operates electrical contacts to achieve electrical sequence functions as desired addition certain manual boxes can be supplied with an alarm indicating lamp and or a key operated electrical N O SPST for operating electrical circuits without activating the tab or lever Cerberus Pyrotronics manual fire alarm boxes are Underwrit Laboratories Inc listed of Application single action models contain one normally open contact for the MS 57 which contains two normally open contacts is intended for use with Cerberus Pyrotronics low voltage These manual boxes can be used for connection to fire alarm systems of other manufacturers reference Information Table the double action box the optional switch on the first action be used for supervisory tamper indication It may also be to alarm one zone of a cross zoned fire extinguishing fire extinguishing system where the main action would the second zone for example for use in the arming of a system optional lamp may be an alarm lamp for the box similar to detector alarm lamp or it may be energized from a remote to indicate the alarm has been received by the system lamp may also be connected to the system so that the first of a double action box will light the lamp For instance feature could be used to discourage pranksters from pulling main action lever information Cerberus Pyrotronics single and double action manual fire boxes are constructed of durable molded polycarbonate matte finish in red with raised lettering in white The for the single action box accommodates a which when operated locks in position after releasing a contact switch Restoring the system to normal only be accomplished by opening the cover of the hinged with an Allen key and then closing and locking the housing for the double action box in addition to the above a tab This tab must be operated first to access to the lever An additional spring contact switch which is released upon operation of the tab is available on Models MS 512C MS 513C MS MS 517C and MS 518 Resetting of the box is as de above with an Allen key desired the boxes can be supplied with a 24V alarm indicating and or key operated switch for special operating functions models are fitted with screw type terminals for special functions as necessary NUMBER Catalog Number 6181 No Mounting Box Key LPT Key Package 2 Allen Keys Data 5 2 and Architect Specifications manual fire alarm box shall be a Cerberus Pyrotronics See chart for model number with Underwrit Laboratories Inc listing body of the manual box shall be hinged to a backplate to which it is locked with an Allen head screw the box after operating shall require opening the box and then locking the body to the backplate shall be made for surface or semi flush mounting to boxes Action Model single action box which shall be of the non code type shall of a molded housing fitted with a lever when operated locks in position after releasing a spring contact switch to effect activation of the alarm circuit Action Model double action box which shall be of the non code type consist of molded housing fitted with a lever a tab It shall be necessary to operate the tab first to provide access to the lever which operated locks in position after releasing a spring loaded switch to effect actuation of the alarm circuit manual box can also be fitted with an alarm lamp and a key switch to achieve the electrical sequence functions Information SPST 125 VAC DC BOX N O SPST 28 VAC DC SPST 125 VAC DC DPST 250 VAC DC 125 VAC DC N O SPST 125 VAC DC BOX N O SPST 28 VAC DC SPST 125 VAC DC N O SPST 125 VAC DC SPST 125 VAC DC N O SPST 28 VAC DC SPST 125 VAC DC DPST 250 VAC DC 125 VAC DC SPST 125 VAC DC N O SPST 125 VAC DC SPST 250 VAC DC additional mounting options refer to the Pyrotronics Device Mounting Guide Contacts Ratings Action Action Alarm Lamp by main action or by external power with and jumper removed SPST 250 VAC DC 125 VAC DC by main action or by external power and jumper removed by main action or by external power with and jumper removed SPST 250 VAC DC 125 VAC DC SPST 250 VAC DC 125 VAC DC The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics control equipment will be considered a misapplication of Pyrotronics equipment and as such void all warranties either expressed or implied with regards to loss damage liabilities and or service problems Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 6 94 Catalog Number 6181