Cerberus Pyrotronics MXL Control Unit

File Preview
File Preview
Click below to download for free

File Data

Name cerberus-pyrotronics-mxl-control-unit-5096432871.pdf
Type PDF
Size 1.06 MB
Downloads

Text Preview

MXL Protection System AND ARCHITECT SPECIFICATIONS FirePrint Application Specific Capacity for over 2,000 Intelli Input Devices Dynamic Supervision of Intelligent Security Device Monitoring Sprinkler Supervision Intelligent Analog Detection Style 6 Class A or Style Class B Detector Sensitivity Readout per NFPA 72 Chapter 7 Style D Class A or Style B B Conventional Initiating Style Z Class A or Style Y B Notification Appliance Degrade Mode Operation Distributed Processing 80 Character Backlit Alphanu Display Thermal Strip Printer Supervised Remote Printer 32 Character Custom Messages Multiple Command Stations Compare System Software Fully Field Programmable Via Computer Menu Driven Operator Commands Central Distributed Architecture ChronoLINK 800 Event History With On Line Off Line User Help Screens Multiple Levels of Password EnviroLINK Automatic Enviro Compensation for Detectors One Person Walk Test by Zone Alarm Verification by Device or Logic Controlled Output Time Base Controlled Output System Holiday Schedule City Tie Lease Line Coded Outputs Supervised Serial Annunciator Interface Interactive VDT Monochrome Color Color Graphics Option Complies with NFPA 72 NEC 760 Power Limited Circuits 864 Compliant 16 Gauge Steel Enclosure Listed 864 1076 ULC Listed FM CSFM NYMEA City of and U S Coast Guard Pre action Releasing NFPA 13 FM Approved for Sprinkler FM Approved for Intrinsically Applications Halon FM 200 Releasing Ap NFPA 12A NFPA 2001 Multi Language Display Intelligent Interface to Building Systems Operates as an Interactive Peer Other MXLs MXL IQs or in a LifeLink Network CXL Command Center Pre Alarm Operation FireFinder Graphics MXL is a microprocessor based advanced protection Its use of unique multiprocessor design with its ability to utilize both analog and conventional devices make it the most flexible and reliable in the life safety field The MXL is ideally suited for institutional and industrial fire security and applications It complies with the requirements of 72 It is UL 864 and 1076 security listed as well as ULC CSFM City of Chicago U S Coast Guard and approved It is also UL listed for releasing per 12A 13 and 2001 for FM 200 Halon Pre Action and Deluge basic MXL control unit consists of the following MMB 2 Main Control Board MPS 6 MPS with MMB 2 Power Supply MKB 2 Annunciator and MME 3 MLE 6 or MSE 2 Enclosures Optional which can be installed with the MXL System NUMBER MOM 2 4 Expansion Card Cage ALD 2I Analog Driver CRM 4 Controllable Relay Module NIM 1R Interface Module REP 1 Network Repeater XLD 1 Series Loop Driver CSM 4 Controllable Module CZM 4 Conventional Zone Module PIM 1 Interface Module CMI 300 CXL Modem Inter Module MOD 16 Output Driver MOI 7 Network MID 16 Input Module PSR 1 Remote Supply DC Supply MXL VDT Interactive Video Display NET 4 Style 4 Network Interface NET 7 Style 7 Interface MXL G Color Graphics MXL GT Color a full range of and IL Series intelligent detec and devices see data sheets Main Control Board function control of the MXL is contained on the MMB 2 Control Board The MMB 2 controls operates and input device identity network communications as as operator commands that are entered through the annunicator keyboard All operations are supported either the MPS 6 or the MPS 12 power supply eliminat the need for external power supplies The MMB 2 is a replacement of the MMB 1 therefore providing total compatibility MMB 2 provides 2 ALD Analog Loop Driver circuits ALD loop can be configured as Style 4 Class B or 6 Class A and can monitor and control up to 60 Pyrotronics analog input devices and 60 pro device relays The MMB 2 is equipped with 2 and codable Style Y Class B or Style Z A notification appliance circuits Each circuit can up to 1.5 amps of Cerberus Pyrotronics audible visual notification appliances MMB 2 includes a built in battery charger and transfer The charger is microprocessor controlled and a brownout circuit that switches the system to batteries during the loss and reduction of the source AC Upon command the system is ca of displaying the real time battery voltage AC and the charge current and other power data on the alphanumeric display It also has a 1 amp 24 VDC that powers the CZM 1 modules MMB 2 is designed with a built in mounting bracket MMB 2 mounts directly to the MBR MP mounting plate mounting in either the MME 3 or MME 6 backbox The MMB 2 can also be mounted in the MBR 2 MBR 1 enclosures MBR 1 requires additional mounting on board 16 bit microprocessor along with nonvolatile and Flash memory allow the system to be custom to meet a wide range of customer requirements MMB 2 provides a port for connection to a laptop allowing for off line field programming Com system configuration can be easily uploaded down edited and changes verified using AccuLINK programming software with integrated Compare software Program options include but are not to EnviroLINK smoke detector environmental with two maintenance alert levels history logging output control by event and change time based control detector sensitivity verification by device or zone 32 character custom messages system operation passwords and coding Annunciator Keypad MKB 2 mounts on a hinged frame in the MXL enclo and provides an 80 character backlit LCD alphanu annunciator which continuously scrolls to display concerning system status along with 32 user defined device messages When multiple occur the MKB 2 displays the last event of the priority Additional data can be viewed by depress the NEXT key At any time the display scroll can be by depressing the HOLD button Switches are for acknowledging fire alarms supervisories conditions and system troubles An individual is also provided for silencing the system notification circuits A separate switch is used for resetting control panel 10 digit numeric keypad is supplied to allow entry of the passwords as well as perform specific menu driven programming and maintenance functions series of switches located on the MKB 2 allows access to the TSP 40 Thermal Strip Printer when set of user assignable keys provide single access to a variety of system commands These may be used to perform system operation such manual relay control zone disconnect etc on the MKB 2 annunciator are system status LED which can function even if the main system fails They provide indication of Main On Fire Alarm Security Condition System Trouble System Audibles Active Silenced and Partial Disable MKB 2 Annunciator communicates with the MMB 2 Control Board through the system network link Power Supply MPS 6 is a fully supervised power supply which the system with primary DC power It is rated at Amps and is unfiltered and unregulated It supplies the Control Unit and its expansion modules with power for normal operation The unit incorporates a circuit breaker on the primary input and includes built in AC line filter for surge and noise suppression The mounts in the MXL enclosure backbox type output circuits for the supervision and control of audible or visual notification appliances such as bells strobes etc Each circuit can provide up to amps 24 VDC of current to power notification appli The CSM 4 is also used for extinguishing agent FM 200 Halon Pre Action Sprinkler and Deluge Leased line and municipal tie connections are possible with the CSM 4 Network Option Module Card Cage MOM 4 Card Cage provides the MXL Main Unit or Units with card slots for option modules Each supplies connection space for either two full width modules ALD 2I CZM 4 NIM 1R XLD 1 or four width option modules CSM 4 CRM 4 CMI 300 NET REP 1 or a combination of one full and two half width Controllable Relay Module Controllable Relay Module CRM 4 is designed to auxiliary control of buil

Related Files