Cerberus Pyrotronics OMM-1 Option Module Cardcage 5022

File Preview
File Preview
Click below to download for free

File Data

Name cerberus-pyrotronics-omm-1-option-module-cardcage-5022-5064819732.pdf
Type PDF
Size 952.98 KB
Downloads

Text Preview

OMM 1 Option Module Cardcage AND ARCHITECT SPECIFICATIONS Cardcage for MXLV Voice Option Modules Mounts Vertically in MXL Backbox Four Keyed Cardslots Card Edge Guides Gold Plated Connectors Configurable Screw Terminals Saddle Clamp Type Terminals Listed ULC Listed FM CSFM NYMEA and City of Chicago Approved OMM 1 is a backplane or cardcage into which all option modules plug It is used in both the MXLV Console enclosure and the MXLRV Remote unit enclosures It mounts vertically to studs in the MBR 2 backbox and provides 4 card clots with card edge guides All MXLV modules are half width size The OMM 1 also screw terminals for termination of all field wiring terminals are saddle clamp type and designed to fit 18 AWG to 14 AWG wire and network communications are provided by either MMB 1 or the PSR 1 depending upon the application cables are supplied with the OMM 1 OMM 1 fits into the same footprint as the MOM 4 MXL module cardcage to 3 OMM 1 or MOM 4 Cardcages can fit in a single enclosure MBR 2 in whatever combination is Ribbon cables are provided for interconnection cardcages No more than 3 OMM 1 may be con together equipment is approved for operation over temperature of 0 to 49 and Architect Specifications Voice System modules shall be plug in type and with a cardcage model OMM 1 The OMM 1 provide slots and card edge guides for up to four modules Card slots shall be pressure type with plated contacts and shall provide keying to avoid of the modules The OMM 1 design shall allow use of any option module in any card slot cardcage shall provide screw terminals for all field Screw terminals shall be saddle clamp type of being used with 18 14 AWG wire OMM 1 Cardcage shall mount in the MBR 2 enclosure and shall include necessary ribbon cables for to the MXL main board MMB 1 or remote supply PSR 1 as well as for interconnection of NUMBER The OMM 1 Information Number Module Cardcage Instructions MXLV Modules Number Supv Module Supv Riser Module Control Card Channel 8 Class B Spkr or Strobe Channel 8 Class B Spkr Zones Channel 8 Class B Spkr or Strobe Channel 8 Class B Spkr Zones Channel 4 Class A Spkr or Strobe Channel 4 Class A Spkr Zones Channel 4 Class A Spkr or Strobe Channel 4 Class A Spkr Zones Watt AMP Spkr Zone Telephone Zone Modules Diagram Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 3 95

Related Files