Cerberus Pyrotronics RC-30U Confirmation Control Module 3167
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-rc-30u-confirmation-control-module-3167-8345602971.pdf |
---|---|
Type | |
Size | 707.91 KB |
Downloads |
Text Preview
RC 30U 3 Confirmation Module 3 Confirmation Module AND ARCHITECT SPECIFICATIONS AND ARCHITECT SPECIFICATIONS Variable Interrupt Period seconds Variable Confirmation Period second to 2 minutes System or Zone Confirmation Placement Supervised FM NYMEA and of Chicago Approved Confirmation Module Model RC 30U is designed to against unwanted system alarm operation which result as an example from the presence of occa momentary but harmless products of combustion RC 30U will interrupt the transmission of an alarm to the system control panel for a factory set period 20 seconds however it is adjustable from 1 to 60 Immediately following the interruption period a period is in effect during which time a subse alarm signal if present will be sent immediately to control panel This confirmation period as factory set is 1 minute however it is dependent upon the setting the confirmation period should an alarm signal be it will put the system into alarm condition Confirmation Module is placement sensitive as Modules connected between the Confirmation receptacle P2 and the control panel are not by its operation Modules connected subsequent receptacle P1 of the Confirmation Module may be This is determined by which plug system or is used system plug orange wire is for basic applications a single alarm interrupt confirmation cycle is suffi See typical connection 1 In this application a Plug Harness Assembly is used between recep P4 and P5 and any alarm signal from a module to receptacle P1 will be interrupted for a period of time from 1 to 30 seconds 20 seconds the standard setting During this period power to the on receptacle P1 is removed a yellow LED is and a system trouble signal is initiated In a high going signal 20 ma is present on a for use as a pre signal or for connection to a device Immediately following the interruption the circuit power is restored the yellow LED is and the system trouble signal is canceled also starts the confirmation period a period during time if any alarm signal is present it will be passed uninterrupted to the control panel and the system go into alarm condition This confirmation period is to the extent that it is a multiple of the duration of interruption cycle One minute is standard If no alarm is present during the confirmation period the RC resets automatically and the system is normal zone plug white wire is used for applications requir various alarm interruption confirmation cycles two or RC 30U will be needed See typical connection 2 this application only alarm signals from modules con to receptacles P1 will not be interrupted confirmed interruption and confirmation cycle described above in a zone mode A yellow trouble LED is provided on RC 30U to annunciate a specific trouble within the RC NUMBER Model RC 30U which occupies two standard module is placement supervised providing a system signal upon removal from the system In addition of the system zone plug and or the special Plug Assembly provides a system trouble signal unit is Underwriters Laboratories Inc listed and Arch and Archiitect Spe for precise time control of an alarm signal shall be provided by a Cerberus Pyrotronics Module Model RC 30U This module shall be interconnected by a ten wire jumper plug and assembly and shall be operable with the system control panel Specciiffications duration of the interruption period shall be capable of set at any precise interval between the time frames one second to sixty seconds Power to modules on the circuit shall be removed a system trouble occur and a high going signal shall be present on a terminal during this period At the end of this period shall be restored to the modules and the confirma period shall begin An alarm signal from the modules the confirmation circuit received during this period shall put the system into alarm condition If no signal is received the RC Module shall reset to A module trouble visual indicator shall be provided the RC 30U module Model RC 30U shall be capable of interrupting and alarm signals on either a total or partial system Model RC 30U shall be Underwriters Laboratories Inc Information Information Requirements 5 mA of interruption period 100 mA of confirmation period 40 mA 40 mA Information Information No Wiring Wiring Note specific color of Plug or Plug Plug orange confirms all zones as function of alarm whereas Zone Plug white may confirm zones and not others Refer to plug arrangement modules controlled in above examples P2 is incoming bus plug and must be connected to panel Operation The RC 30U will interrupt the transmission an alarm signal to the system control panel for a set period of 20 seconds However it is adjust from 1 to 40 seconds Immediately following the period A confirmation period in effect during time a subsequent alarm signal if present will be immediately to the control panel This confirmation as factory set is approximately 1 minute it is dependent upon the interrupt setting If in setting is required consult your authorized Pyrotronics Service Technician The RC 30U cannot be used to confirm shorting zones Terminals 1 and 2 are provided should a trouble output be desired Remove jumper terminals 1 and 2 and terminal 1 RC 30U to terminals 1 and 2 or and terminal 2 RC 30U to terminal 3 TL 30U TL 30U delay must not exceed 200 seconds The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics control equipment will be considered a of Cerberus Pyrotronics equipment and as such void all warranties either expressed or implied in regard to loss damage and or service problems Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 www cerbpyro com in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1997 sheet dated 9 95