Cerberus Pyrotronics VoiceCom Emergency Voice Alarm Communication System 3700
File Preview
Click below to download for free
Click below to download for free
File Data
Name | cerberus-pyrotronics-voicecom-emergency-voice-alarm-communication-system-3700-9804527163.pdf |
---|---|
Type | |
Size | 1.28 MB |
Downloads |
Text Preview
VoiceCom Voice Alarm Communication System AND ARCHITECT SPECIFICATIONS Listed 864 CSFM NYMEA Approved Style Y Class B and Style Z Class A and strobe circuits Power Supply and Battery Charger output over voltage protection Dry contact or polarity reversal activation Activation inputs are fully supervised High efficiency digital amplifier True 100 Watts RMS output capacity 25 or 70.7 VRMS audio field selected Up to 11 optional Speaker and supervision modules in one cabinet All outputs are power limited Stand alone or for use with any Fire Alarm Control panel Optional digital MessageMaker is field Coded tone option Backup evacuation tone option VoiceCom is a PRE BUILT emergency voice and tone communication system The VoiceCom can be used a stand alone system or in conjunction with any listed fire alarm control panel The VoiceCom is self contained and has its own power supply charger brown out supervision and transfer earth detection trouble and trouble ring back circuitry It incorporates an emergency paging microphone tone 50 Watt RMS audio amplifier and a speaker circuit The power supply is capable of a full Amps DC at 24 volts A set of dry form trouble is provided for external connection to a fire alarm panel or fire suppression system Speaker and circuits are supervised by the VoiceCom panel The supply is capable of charging up to 24 AH batteries only 6 AH batteries are required for 24 hours of and 15 minutes of maximum alarm load operation expansion of the VoiceCom system can be with the use of speaker 101 SPK and strobe supervisory modules Up to five speaker and strobe supervisory modules will mount in the same enclosure in any combination An optional message unit called the MM 1 MessageMaker can added in the place of two speaker or strobe zone three zone spaces in the large cabinet option MM 1 comes pre installed in the VoiceCom MM package The MM 1 comes with 20 seconds of programmable digital voice message capacity and 18 of capacity for virtually any evacuation tone s Through the use of up to two optional 20 second expansion devices up to 60 seconds of a message can be recorded The digital message can recorded through audio coupling using the microphone the MM 1 or electrically with a tape recorder using the jack on the MM 1 The MM 1 MessageMaker with a standard test message alert tone alarm tone NUMBER a standard evacuation message which can be over if a specific message and tone are required The MessageMaker has a built in sequencer which an ALERT tone followed by the emergency and in turn followed by the ALARM tone The tone can be coded to conform to any local and codes The emergency message can be set to up to seven times with the setting of DIP switches digital message can also be programmed to repeat the system is reset The MM 1 MessageMaker uses memory thus retaining its messages indefi As a further safeguard the 101 AMP amplifier will activate an evacuation tone backup in the event a MessageMaker failure auxiliary audio input can be used for connection to a paging microphone RMT PG telephone paging or required audio signal The auxiliary audio input can set to the lowest priority so that it will be disabled in the of an alarm condition or when the system micro button is pressed The auxiliary audio input can also set to the highest priority ensuring that the remote RMT PG has precedence over the VoiceCom the VoiceCom modules options are centrally monitored ground faults and supervision troubles Troubles are on the panel via a LED and an audible trouble A form system trouble relay is used to create a at the fire alarm control panel The audible trouble may be silenced by activating the trouble silence Full annunciation of troubles is provided at both the control panel and the individual modules LEDs are for short circuit and open circuit trouble annuncia at every module The system can be configured to a reminder audible signal after the trouble has been VoiceCom provides 50 Watts RMS of voice and tone power per amplifier Up to two amplifiers can be in VoiceCom larger enclosure The system can be in the field for 25 or 70.7 VRMS operation It will the requirements of an Occupancy and locations where voice and tone broadcasting is The VoiceCom incorporates a high efficiency that requires minimal energy for its operation Up 100 Watts RMS can be split in any ratio by up to twelve circuits Up to eleven strobe circuits can be in the VoiceCom cabinet to comply with require such as ADA A remote reset input is available to VoiceCom from a distant control panel The can be made latching or non latching thus only two wires from the control panel for both and reset functions VoiceCom is capable of recognizing a short on a zone the speech tone or strobe is active on other zones circuited zones are isolated from the system and a zone trouble The type of zone fault is annunci at the zone card and a general system trouble audible and LED are activated at the main control module of its full speaker zone isolation capabilities the meets the requirements specified by NFPA 72 survivability And Architect Specification emergency voice and tone communication system be the Cerberus Pyrotronics model VoiceCom The shall be a pre built system and shall only require wires from a polarity reversal circuit or a dry contact for It shall supervise the dry contact if used provide a form trouble relay activation in the event a system fault The VoiceCom shall incorporate 50 Watts RMS amplifiers for both tone and speech amplification system shall have a load capacity of up to 100 watts the VoiceCom system shall be capable of 50 watts of audio with full backup The VoiceCom be capable of operating as a stand alone system or the activation of the fire alarm suppression system VoiceCom shall include a regulated power supply and be capable of charging and housing its own batteries shall be no need to calculate the load requirements draw any energy from the fire alarm suppression system VoiceCom shall come with one speaker supervisory as a standard and shall be capable of supervising combination of up to eleven speaker 101 SPK and or 101 STRB monitoring modules full set of control switches including an call silence and shall be available at VoiceCom The VoiceCom control panel shall also a green On LED a red LED a yellow Out LED and a yellow Trouble LED VoiceCom shall be able to detect a short on any or strobe zone during the normal and alarm mode shorted zone shall be isolated from the system and a LED on the supervised zone shall indicate the circuit condition The system shall produce an and visual signal indicating that a trouble condition occurred Similarly an open circuit shall create a condition and corresponding LED annunciation at affected zone and at the main control module Zones are not shorted or opened shall remain operational VoiceCom shall be able to detect a Brown Out condi on the AC supply In the Brown Out condition the shall activate a dedicated LED and an audible signal Ground faults shall activate the system LED and the audible trouble signal as well as LEDs indicating negative and positive ground VoiceCom shall be field configurable for 25 or 70.7 volt audio output via program jumpers VoiceCom shall have a digital message player recorder MM 1 The digital message player recorder shall capable of storing alert and evacuation tones as well as emergency voice message It shall be possible to the digital message and tones in the field using a acoustic microphone or a headphone jack con to a tape recorder There shall be no need for the of eproms in order to program the digital message The digital message player recorder shall supervised by the VoiceCom The VoiceCom shall a backup evacuation tone in the event of a digital player recorder failure alarm condition shall cause an audible signal and a red to activate A Voic