Siemens ADB-3 ADBI-60 Audible Bases, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

cid 1 cid 2 cid 3 cid 4 cid 2 cid 3 cid 5 cid 6 cid 7 cid 8 cid 9 cid 10 cid 9 cid 6 cid 9 cid 11 cid 12 cid 1 cid 2 cid 3 cid 4 cid 10 cid 11 cid 12 cid 4 cid 7 cid 8 cid 2 cid 3 ADB 3 cid 1 cid 2 cid 3 cid 4 cid 2 cid 3 cid 5 cid 6 cid 7 cid 8 cid 9 cid 3 cid 10 cid 11 cid 3 cid 10 cid 12 cid 13 cid 1 cid 6 cid 1 cid 2 cid 3 Model ADB 3 Audible Base consists of a Series 3 base combined with an audible device All field wiring at a four position terminal block located on the back of the unit The is used only with Series 3 detectors and is powered directly from the circuit Refer to Table 1 for compatible detector model numbers and the Installation Instructions The audible device sounds when the detector and stops sounding when the system is reset Refer to Figure 1 the Wiring Diagram Only one device is guaranteed to activate per The ADB 3 is UL 268 listed and meets the UL audibility sound output of decibels at 10 feet ADB 3 must not be used as the primary evacuation but only as a supplemental device Do not use looped wire under Terminal 5 of DB 3S base Use a break in the wire at the terminal to provide supervision of connection 1 Installation Wiring Diagram ADBI 60 cid 1 cid 2 cid 3 cid 4 cid 2 cid 3 cid 5 cid 6 cid 7 cid 8 cid 9 cid 3 cid 10 cid 11 cid 3 cid 10 cid 12 cid 13 cid 1 cid 6 cid 1 cid 2 Model ADBI 60 Audible Base consists a standard Series 3 base combined with an audible device All field wiring at two four position terminal blocks located on the back of the unit ADBI 60 is used with System XL3 System IXL ICON 1 System MXL or MXL IQ detectors Refer to Table 1 for compatible detector model and the related Installation Instructions The ADBI 60 operates as below Refer to Figures 2 3 4 5 6 7 and 8 cid 7 2 Diagram for ADBI 60 Audibles by System XL3 different configurations can provide audible signal circuit power to the at terminals 1 through 4 as shown in Figures 2 3 4 5 6 7 and 8 the supervisory state no alarms the polarity of the power to all is in a reversed off normal state resulting in zero current flow to base alarm reported to System XL3 or System MXL MXL IQ activates the or TRI B6R module and triggers the AA 30U AE 30U modules See 3 and 4 The power to all ADBI 60s reverses polarity for normal but no audibles sound The System XL3 or MXL MXL IQ may then command the ADBI 60 under programmed control to sound via the in the addressable detector plugged into each ADBI 60 For IXL the CE S is programmed to follow the system alarm relay See 7 and 8 Only those ADBI 60s connected to a detector in alarm will The ADBI 60 is UL 268 listed and meets the UL audibility sound output of 85 decibels at 10 feet The ADBI 60 is used for primary building evacuation NFPA 72 that the source of audible power be capable of operat all primary evacuation audibles at the same time RATINGS AND CONSTRAINTS ADB 3 Rating On AC 28 48 VDC peak full wave battery 20 27 VDC Supervisory 0A 13mA at 25 VDC Only one device is guaranteed to activate per zone ADBI 60 Rating 25 5 VDC Supervisory 0A 37mA at 25 VDC The maximum number of ADBI 60s per an AA 30U AE 30U SPX 1 SMB 1 2 IXL ICON 1 or CSM 4 Bell power loop is 40 no other devices connected and with the maximum loop current The number of ADBI 60s cannot exceed the maximum current to the loop See the System XL3 Manual P N 315 the IXL Manual P N 315 092371 the MXL Manual 315 092036 or the MXL IQ Manual P N 315 093624 for compatibility details of INX ALD and audible circuit wiring Maximum line resistance permitted both wires not including the end line resistor is 3 ohms A minimum of 14 AWG wire must be used T tapping of the audible circuit Figures 2 3 4 5 and 6 is not the ADBI 60 is powered by System XL3 Figure 2 the total System available for indicating appliances is 5A If more than 5A is the configuration in Figure 3 or Figure 4 must be used for power an external power source is used on the SPX 1 tie the negative side the external power supply to the negative of the PSX 24 VDC power that is from terminal 1 or 2 of P9 or P10 on the PSX to terminal of the SPX 1 The 24 VDC external power source should not be powering any devices that could generate noise on the line such as Alarm system or devices which are not part of the fire system If there is any ground detection with the 24 VDC power disconnect it Use the AA 30U for either Style Z Class A or Style Y Class B the AE 30U for Class B wiring only Figures 3 and 4 Diagram for ADBI 60 Audibles Powered Auxiliary Power Supply with Battery Backup 3 Diagram for ADBI 60 Audibles Powered Auxiliary Power Supply No Battery Backup 4 5 Diagram for ADBI 60 Audibles by System MXL MXL IQ Main Board 6 Diagram for ADBI 60 Audibles by System MXL MXL IQ CSM 4 Module 7 Diagram for ADBI 60 Audibles by IXL System Set the CE S address to 201 to the System alarm relay Only detectors attached to the can be used with the The ADBI 60 turns on when associated detector goes alarm The UL listed power supply battery backup is rated 24 VDC It must supply current to handle at 10 of the ADBI 60s to it 8 Diagram for ADBI 60 Audibles by a Remote Power Supply System IXL The ADBI 60 is powered by System MXL MXL IQ Figures 5 and 6 System power for indicating appliances is 5A If more than 5A is use the configuration in Figure 3 or Figure 4 for auxiliary See Note above Connect terminal 6 of the PS 35 Figures 3 and 4 to the minus DC of the System XL3 or MXL MXL IQ main power supply for proper fault supervision The ADBI 60 is powered by System IXL Figure 7 the System power indicating appliances is 3A If more than 3A is required use the in Figure 8 Each audible base is marked as follows to indicate its type ADBI 60 ADB 3 D additional information on the modules used in an individual refer to the Installation Instructions for that particular or contact your authorized Siemens Building Technologies representative PLACEMENT table at right lists the detectors that can be used with the ADB 3 and Detector Bases along with the appropriate Installation Instructions though no specific spacings are allocated to the detectors used with bases use 30 foot center spacing 900 sq ft as referred to in NFPA 72 National Fire Alarm Code Chapter 5 and CAN ULC S524 as a or starting point if practical in a detector installation layout This spacing based on ideal conditions

Related Files