Siemens ADBH-11 Audible Base, Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name siemens-adbh-11-audible-base-installation-instructions-1623784950.pdf
Type PDF
Size 708.86 KB
Downloads

Text Preview

Installation Instructions ADBH 11 Base Model ADBH 11 Audible Base from Siemens Industry consists of a standard Series 11 base combined with audible device All field wiring terminates at two four terminal blocks located on the back of the unit ADBH 11 is used with the polarity insensitive HFP 11 HFPO 11 SFP 11 SFPT 11 and SFPO 11 The ADBH 11 operates as described below to Figures 1 2 3 and 4 ADBH 11 can generate either steady or temporal with the insertion of a jumper at the terminal block to Tone Selection on page 7 ADBH 11 is a UL268 listed smoke detector supple device which combines detector base and device functions When used in conjunction with compatible Siemens equipment the ADBH 11 be used in lieu of single multiple station smoke to achieve enhanced system level functionality applications are sleeping rooms in hotels guest dormitories day care and residential board and facilities as designated in NFPA 72 SFPT 11 and SFPO 11 detectors are approved for use Canada only 315 033210 7 Inc Inc Inc Industry Inc Inc TTTTTececececechnologies Di Di Di Division Di 5 3 2 DLC LOOP OF 1 2 3 NEXT 1 2 2 2 3 4 Polarity shown in active state at terminals 1 and 2 of ADBH 11 and 1 4 of ZIC 4A polarity must be maintained or audible base will not operate properly Each base must be tested to verify operation Tone selection refer to page 7 for more information ADBH 11 terminals 5 8 are polarity insensitive Line 1 and Line 2 can be either line the loop ADBH 11 shown Style Z Class A It may also be wired as Style Y Class B ZIC 4A Notification Applicance Circuits provide 4 outputs that can be configured for A or Class B Refer to the ZIC 4A Installation Instructions P N 315 033050 EOL resistor 24k ohms watt 5 P N 140 820405 2 Diagram for ADBH 11 Audibles Powered by ZIC 4A System RATINGS AND CONSTRAINTS Rating 17 31 VDC Supervisory 0A 24mA at 25 VDC Sound Pressure Level 78dB ADBH 11 is energized by an auxiliary power supply such PS 35 with AE 30U System 3 power supply PAD 3 power supply ZIC 4A FireFinder XLS zone 3 2 DLC FS DLC FDLC OF FIREFINDER XLS SYSTEM 1 2 3 NEXT 1 2 2 PAD 3 CIRCUIT PAD 3 CIRCUIT 5 2.2K 1 2W 140 820380 NAC circuits polarity shown in active state Proper polarity must maintained or audible base will not operate properly Each base must be tested to verify operation Tone selection refer to page 7 for more information ADBH 11 is polarity insensitive Line 1 and Line 2 can be either ADBH 11 shown Style Z Class A It may also be wired as Max Current 3.0 AMPS Refer to PAD 3 Installation Instructions of the loop Y Class B 315 099082 3 Diagram for ADBH 11 Audibles Powered by PAD 3 card or NAC circuits on the FS 250 or FS 250C board Refer to Figures 1 2 3 and 4 Also any UL 24VDC auxiliary power supply notification appli circuit listed for fire protection signaling use can used for ADBH 11 The maximum number of ADBH 11s is related to the current rating and the power line resistance of auxiliary power supplies applied on the ADBH 11

Related Files