Siemens ADBX-11 Audible Base, Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name siemens-adbx-11-audible-base-installation-instructions-4695013872.pdf
Type PDF
Size 855.10 KB
Downloads

Text Preview

Installation Instructions ADBX 11 Base ADBX 11 Model ADBX 11 Audible Base consists of a standard 11 base combined with an audible device All field terminates at two four position terminal blocks on the back of the unit The ADBX 11 is used with and FPT 11 detectors P N 315 095921 and FS DPT and FS DT detectors P N 315 699481 ADBX 11 operates as described below Refer to 1 2 3 4 and 5 ADBX 11 can generate either steady or temporal with the insertion of a jumper at the terminal block to Tone Selection on page 2 NOTE ADBX 11 is a UL268 listed smoke detector device which combines detector base audible device functions It meets or exceeds the 85 at 10 foot audibility requirement for smoke alarms as in UL217 Single and Multiple Station Smoke and NFPA 72 for sleeping areas When used in with listed compatible Siemens equipment ADBX 11 may be used in lieu of single multiple smoke alarms to achieve enhanced system functionality Typical applications are sleeping in hotels guest suites dormitories day care and board and care facilities as designated in 72 The number of ADBX 11s cannot exceed maximum current available to the See the MXL Manual P N 315 or the MXL IQ Manual P N for the compatibility details of and notification appliance circuit wiring Maximum line resistance permitted both wires including the end of line resistor is 3 ohms minimum of 14 AWG wire must be used T tapping of the notification appliance circuit 1 2 3 4 and 5 is not allowed the ADBX 11 is powered by System MXL Figures 3 4 and 5 or FS 100 Figure the notification appliance circuits supply If more than 1.5A is required use the in Figure 1 or Figure 2 for auxiliary See Note above Connect terminal 6 of the PS 35 Figures 1 and 2 the minus DC side of the MXL MXL IQ main supply for proper ground fault supervision For additional on used in an individual system to the Installation Instructions for particular module or contact your Siemens RATINGS AND CONSTRAINTS PLACEMENT ADBX 11 Rating 17 31 VDC Supervisory 0A 24mA at 25 VDC The maximum number of ADBX 11s per an SMB 1 2 or CSM 4 notification circuit is 60 with no other devices and with the maximum loop current FP 11 FPT 11 FS DP FS DT and FS DPT can be used with the ADBX 11 Detector Base to the FP 11 FPT 11 Installation Instructions P N or the FS DP FS DT FS DPT Installation P N 315 699481 as applicable for further though no specific spacings are allocated to the used with this base use 30 foot center spacing sq ft as referred to in NFPA Standard 72 National Alarm Code Chapter 5 and CAN ULC S524 as a Industry Inc Technologies Division Park NJ 315 096228 9 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario L6T 5E4 Canada or starting point if practical in a detector installation This spacing is based on ideal conditions ceiling no air movement and no physical all installations except in special circumstances like room underfloors locate the detector on the a minimum of 6 inches from a side wall or on a between 4 and 6 inches from the ceiling questions arise regarding detector placement it is important that the drawings provided or by Siemens Industry Inc or by its authorized be followed The detector placements shown these drawings were chosen after a careful evaluation all facets of protecting the area Environmental factors as air current temperature humidity air pressure the nature of the fire load are carefully considered consideration is given to room or area and the type of ceiling sloped or flat or beamed Siemens Industry Inc s extensive in the design of fire detection systems assures detector placement and is reflected in these Follow sound engineering judgment made by personnel WIRING THE ADBX 11 BASE to Figure 6 Audible base model ADBX 11 should interconnected as shown in the Installation Wiring above and wired to the specific system modules control panels following the appropriate instructions operation with System MXL MXL IQ note any limitations the number of audible bases permitted on each MMB SMB 1 2 or CSM 4 audible circuit depending on the cable resistance for each audible signal circuit See RATINGS section SELECTION audible base Model ADBX 11 the user can either temporal tone or steady tone Refer to 7 Temporal Tone Terminals 3 and 4 are shorted a jumper Steady Tone Terminals 3 and 4 are not without a jumper MOUNTING THE ADBX 11 BASE detector base comes from the factory prewired All and initiating circuits are connected directly to back of the ADBX 11 audible base using the four terminal blocks The Audible Base Model ADBX 11 at only to a 4 inch square electrical with extension the Detector Base Route all wires out from the outlet box When the alarm LED viewing is critical position the mark on the base in the intended direction to Figure 8 Make connections directly to the audible base located on the back of the base Refer to related lnstallation Wiring Diagram After all bases are installed check loop continuity ADBX 11 loop continuity check refer to the MXL or MXL IQ Manual Checkout If loop continuity is acceptable proceed with head installation

Related Files