Siemens Cerberus PRO Marine Fire and Detection Equipment, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-cerberus-pro-marine-fire-and-detection-equipment-data-sheet-5679823014.pdf |
---|---|
Type | |
Size | 1.13 MB |
Downloads |
Text Preview
PRO Fire and Detection Equipment FH 2071 UM I BP 62 I USCG XPLATE Architect Engineer Specifications Product Overview Marine equipment is used with Cerberus 252 point Model FC922 and 504 point FC924 addressable fire alarm control FACPs design allows for protection of in harsh climates and most parts used in Marine fire have passed salt spray mist for Exceptional Degree of per USCG guidelines Models OH921 OP921 HI921 Siemens and series devices properties of Model FH 2071 UM include fully gasket sealed outer door draw latches for secure closure wire braided corrosion resistant isolators one 1 battery bracket which holds two batteries one 1 AC line EMI filter set Model BP 62 provides back up power for Marine only 16AH Standby power 24VDC with metal jacket operable between to176 80 comes with two 2 batteries per order USCG XPLATE is required for Marine in order to reduce radio interference RFI 864 10th Edition Listed ULC S527 Listed ABS Type Approval Lloyd Register Type States Coast Guard USCG Approved Exceptional Degree of Protection CFR Title 46 Subpart 161.002 60 0 Fire and Detection Control is an advanced Siemens fire safety system for use with Cerberus PRO 252 point Model FC922 or 504 point addressable FACPs for Marine specific installs and other harsh applications enclosure used in Marine applications is robust and weather resistant Its design is customized for Marine installs due to the conditions at sea equipment will regularly encounter In order to provide secure fastening Model FH 2071 UM shipment includes a fully gasket sealed outer door latches as well as wire braided corrosion resistant vibration isolators all Marine installations that use Siemens XTRI series devices a specific Model USCG XPLATE is required and must be ordered separately faceplate helps diminish RFI exposure and fits on the front of each XTRI module the system batteries Model BP 62 are used to provide back up power Each battery which rated at 16AH can withstand as low as 40 and as high as 176 80 Application Data equipment used in Marine applications generates and radiates radio energy If the equipment is not installed properly and is attempted be used in ways that are different from the instructions found in the manual A6V10519176 this could subsequently result in interference with communications the exception of the inner door the Marine enclosure Model FH 2071 is shipped complete A trained Siemens representative is required to wire assemble the Marine equipment at the site Actual FACPs are delivered in parts Pre installed components include one 1 EMI filter as well as 1 system battery bracket components be ordered separately one 1 system operating electronic according to order two 2 16AH batteries material and option as required Pages 4 6 for the list of individual parts Model Cerberus PRO Marine Fire and Detection Equipment is UL 864 10th Edition USCG Approved per CFR Title 46 Subpart 161.002 60 0 Refer to Cerberus 252 504 point addressable panel datasheet 9815 for more data Infrastructure Building Products usa siemens com fire Data Sheet 9822 Ordered separately each faceplate fits one 1 170W power Model XTRI series devices Cerberus PRO Marine Equipment Marine Enclosure FH 2071 UM is the enclosure designed for use in PRO Marine and other harsh environment One 1 outer door one 1 backbox and 1 battery bracket come standard in each Model FH shipment The inner door Model FHD2004 U1 only available in Black houses the system operating Models FCM2018 U3 and FCM2019 U3 The back box supports the fire terminal Model FTI2001 U1 and optionally supports the Model FCA2015 U1 as well as the releasing Model XCI2001 U1 size 30.6 77.7 cm H 22 55.9 cm W 6.31 16 cm D weight 48 Lbs 21.8 kg Optional Accessories Batteries for Marine Applications in Marine applications the Model BP 62 battery set auxiliary emergency standby power at 24VDC case of system power failure from the main source battery which is rated at 16AH can operate in ranging as low as 40 degrees and as high 176 80 Model BP 62 contains two 2 batteries order batteries are generally designed by major As the manufacturers improve the design of batteries the amp hour rating may change the dimensions of the batteries will remain the to ensure proper fit in the system enclosures as Model BP 62 is required for use in Marine applications should only be connected when each panel is Cover Plate XTRI Series Devices USCG XPLATE is a metal cover faceplate used in applications When Siemens XTRI Series modules are used the plate is then required for and is fitted over each device protecting it from RFI size 12.7 cm H 12.7 cm W 0.6 cm D weight oz 99.2 g Model Cerberus PRO System Components Interface Unit Operating Interface Unit Model FCM2018 U3 or Model functions as the operating interface and microprocessor for Model FC922 and FC924 control operating interface unit offers multi use capability the end user to promptly events to control the NACs of the FACP and to reset the panel manually data relative to the nature and location of events also be displayed via a backlit 2 5.1 cm x 4.75 cm LCD screen and the four way navigation push at the top of the FACP For applications in Canada that require a Cerberus operating unit with LEDs Model FCM2035 U3 must be Boards periphery boards Models FCI2016 U1 and FCI2017 serve as the main operating components for Cerberus 252 504 point addressable FACPs Each module and monitors input device identity as well as the signaling line circuits SLCs that communicate smoke detectors and other field devices i e C NET Supply system functions are powered internally from the 170W supply Model FP2011 U1 which is housed in the enclosure FH 2071 UM Each power supply primary 24VDC nominal power for routine system to the Cerberus PRO 252 point addressable Model FC922 and the 504 point addressable panel FC924 170 Watt power supply incorporates a 4.0A non slow blow fuse on the primary input and a built in AC line filter for surge and noise Model FP2011 U1 mounts in the panel and there are no serviceable parts to be Model FP2011 U1 is filtered and regulated is rated at 6.5Amps Cerberus PRO Optional Accessories Module SafeDLINK network module Model FN2001 U1 is used network 16 FACPs or fire terminals via the C NET system Model FN2001 U1 is plugged into the Standard Unit Models FCM2018 U3 R3 or the Ope