Siemens Cerberus PRO System A comprehensive fire-protection system (for Canada), Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data Sheet Supervised remote printer via the Peripheral Module for the 252 504 point systems Menu driven operator commands 5,000 event history logging capability on line and off line reports Off line reports can be viewed the custom programming tool EEPROM software compatible Multiple levels of password protection Automatic environmental for smoke detectors Pre alarm operation Alarm verification by device or zone Degrade mode operation Logic controlled output functions Optional city tie leased line module Distributed processing Emergency Alarm events for CO per NFPA 720 for the 252 504 point systems Optional notification appliance circuit expansion module Up to 3.0 amps 24VDC load per output Module used for 252 504 point systems per NFPA 72 Detector Sensitivity Readout Printout NEC 760 power limited circuits ULC Listed ULC compliant 3010 CSFM 7165 0067 0259 FDNY 6104 Approved PRO comprehensive fire protection system AND ENGINEER SPECIFICATIONS Standard 252 point and 504 point systems Remote viewing for the 252 and 504 point systems One 1 or 2 two height enclosures Powerful but user system interface Softkey buttons RS interface Four way navigation menu extended views capability Primary regulated power 300 Watts is rated at 11.5 Amps 170 Watts is rated at 6.5 Amps Universal AC power input 120VAC or 240VAC 50 60Hz 2.0A max Fully field programmable via a PC Built in strobe synchronization protocol Global annunciation and control Several relay commands Alarm Supervisory etc Light emitting diodes LEDs for Alarm Supervisory Silenced Fault Trouble and system LEDs Alarm command has a larger distinctive LED LED option provides LED annunciation system activity SureWireTM addressable loop technology Patented polarity insensitive detection circuits Intelligent analog detection A or B Supports FirePrintTM detection Supports single person Test Sprinkler Supervision End user screens Multiple command stations Supports pre action deluge and releasing for 504 point systems Releasing valve monitoring Backlit liquid crystal display LCD Overview Cerberus PRO System a comprehensive fire system from Siemens Fire Safety is a advanced fire and life safety system Cerberus PRO system provides easy operation via push button soft keys a backlit LCD screen and a four way navigation push button all located in upper portion of each panel the use of its unique multiprocessor design along with its ability to utilize detection devices Cerberus PRO a flexible and highly configurable fire SureWire addressable loop technology is by Cerberus PRO PRO Safety Security Products for infrastructure PRO is ideally suited for mid market via its 252 and 504 point addressable fire panel FACP which are each systems conjunction with these new improved FACPs is a line of intelligent detectors For the Multi Criteria Fire CO Detector with is cutting edge technology for applications such as carbon monoxide The Photoelectric Smoke Detector uses circuitry and surface mount for peak dependability Overview PRO System Components 504 point Cerberus PRO system 504 point Cerberus PRO fire system Cerberus PRO Model FC922 252 point and FC924 addressable FACP is designed to meet the fire needs of mid size buildings advanced panel offers features typically required in buildings in a package that is easy to install and priced Additionally Models FC922 and are networkable allowing the systems to fulfill the fire protection needs of the building FC922 and FC924 utilize a two height unit The following components comprise a two height unit enclosure Operating unit Periphery board Power supplies System enclosures C NET Network Module C NET Network Module C WEB network module Model FN2001 U1 is used to up to 16 FACPs and the Fire Terminal Model via the C NET system bus The C WEB network is plugged into the Operating Unit Model or Model FCM2035 U3 FN2001 U1 supports networking the following systems Model FC922 Model FC924 Model FT924 Model FN2001 U1 connects to system bus inputs and and the module has ground fault monitoring as as an integrated degrade mode function networking is accomplished with one 1 module simple loop trouble per panel There is isolation between the system bus and the FACP Canada Limited Standard Operating Unit Operating Unit with LEDs Interface Unit Operating Interface Unit Model FCM2018 U3 or Operating Interface Unit with LEDs Model is the operator interface and central for the Fire Terminal Model FT924 and PRO FACPs Models FC922 and FC924 FCM2018 U3 or Model FCM2035 U3 provides capability for each end user to efficiently events to quickly control the signaling SCs of the corresponding FACP and to permit a reset of the respective system Detailed about the nature and location of the events displayed via a 5.1 cm 12.1 cm backlit LCD FCM2018 U3 or Model FCM2035 U3 contains the program configuration created in The controller in each interface module provides system logic and supervision Operating Unit allows for connection to the Peripheral Module Model FCA2018 U1 and or Remote Terminal Displays Models FT2014 U3 R3 R3 board for 252 point Periphery board for 504 point PRO fire system Cerberus PRO fire system Boards periphery boards Models FCI2016 U1 and encompass the key components for the Cerberus PRO panels Models FC922 and Each module operates and monitors input identity as well as controls the signaling line that communicate with smoke detectors and field devices i e C NET periphery board is equipped with two 2 B Style Y or 1 Class A Z circuit providing 24VDC nominal at a 3A per maximum of audible visual signaling circuits periphery boards mount directly on the enclosure back of the Model FC922 and Model FC922 Cerberus PRO Models FCI2016 U1 FCI2017 U1 provide two 2 auxiliary powered short circuit protected regulated 24VDC 1.5A max that supply to external devices or modules PRO PRO Components continued Terminal and equipment Fire Terminal Model FT924 consists of the Fire Board Model FTI2001 U1 the Operating Unit FCM2018 U3 or Model FCM2035 U3 and a one enclosure Model FT924 terminal contains one 1 backlit 5.1 12.1 cm Video Graphics Array VGA LCD screen with LEDs for displaying system An audible will sound when there are events on the system display of each operating unit categorizes events by providing a separate event tab for Alarm Emergency Supervisory and Trouble events The quantity of events of each type is listed in each event tab The provides two 2 full lines of text message for each event can have a 40 character custom message

Related Files