Siemens Cerberus PRO Tabular Annunciators Series, Data sheet

File Preview
File Preview
Click below to download for free

Text Preview

PRO Annunciators FT2008 U1 R1 I FT2018 U1 R1 16 zone FT2009 U1 R1 I FT2019 U1 R1 32 zone FTH2073 UA Universal Enclosure Architect Engineer Specifications Product Overview Tabular annunciators come in either 16 or 32 zones and are available in black or red 16 zone annunciators Models FT2008 FT2018 U1 R1 32 zone annunciators Models FT2009 FT2019 U1 R1 Each module requires external power 24 DC for operation System power is obtained from either a PRO addressable panel or a separate 24VDC power supply Each 200x series of tabular annunciator control of Acknowledge Reset Unsilence and Lamp Test system remotely Operated and supervised via a RS bus Maximum eight 8 modules allowed each RS interface All user control buttons on the 200x are key switch T 45 key protected Annunciator backboxes contain six 6 allowing single gang double gang 4 inch square 10.2 cm mounting Set baud DIP switches Two 2 cable ties and one 1 end of line jumper are included UL 864 10th Edition Listed ULC S527 3rd Listed FM 3010 Approved Tabular Annunciators from Siemens Fire Safety allow system events sent Cerberus PRO addressable panels to be displayed remotely in real time Model FT2008 FT2018 series of tabular annunciators have 16 zones and the FT2009 FT2019 series use 32 zones Up to two 2 light emitting diodes can be used per zone The 2018 and 2019 series are identical to the 2008 2009 series but do not have any control capabilities buttons or key switch Annunciators provide outputs for system and zone status are available in black or red For Cerberus PRO 50 point addressable panels Model FC901 built in RS interface controls the operation and supervision of the 16 zone 32 zone Tabular Annunciators Model Model FTH2073 UA is a universal enclosure for housing annunciators It is protected T 45 Key and has a plexi glass front so that the status can be viewed It is louvered to attain the appropriate levels meeting regulatory requirements The Universal Enclosure also brackets and hardware needed for mounting the annunciators conjunction with View Plate Model FTH073 VP can be Universal and provides a better aesthetic when housing and covers the unused portion the Universal Enclosure Model FT2007 S1 is a spare hardware kit the tabular annunciators Models FT2008 FT2018 FT2019 and includes items as cable ties EOL screws etc Model Infrastructure Building Products usa siemens com fire Data Sheet 9825 Specifications Tabular Annunciators provide 16 zones Model FT2008 U1 R1 FT2018 U1 R1 32 zones via Model FT2009 U1 R1 FT2019 U1 R1 on Cerberus PRO panels Each annunciator requires 24VDC external power directly either the panel or from a separate UL Listed 24VDC power supply source applications for 50 point FACP require use of a separately listed power supply the annunciators annunciators easily and promptly display user defined system commands Unsilence Reset Acknowledge Test Model FT2018 U1 system commands are operated and supervised by a RS interface tabular annunciator backboxes have six 6 mounting holes allowing for double gang or 4 inch square 10.2 cm mounting Two 2 cable and one 1 EOL jumper are included per order annunciator control features on FT2008 and FT2009 series tabular are key switch protected T 45 key and its front end design is to the modern sleek appearance of the Cerberus PRO addressable panels Temperature and Humidity Range Cerberus PRO Tabular Annunciators are UL Listed for indoor dry locations within a temperature range of 120 3 49 2 to 32 3 0 2 and a relative humidity of 93 2 at a temperature of 90 3 32 2 Model FT2019 R1 Properties Data Inputs Location Operating Voltage 24VDC nominal 30 VDC Temperature Current FT2018 U1 R1 Current FT2019 U1 R1 Current interface cross section FT2018 U1 R1 cm x 18.7 cm x 5.1 cm 18 28 AWG Wire Gauge FT2019 U1 R1 cm x 18.7 cm x 5.1 cm dry 120 49 140 60 Temperature relative Properties x 7.4 x 2.0 W x H x D x 7.4 x 2.0 W x H x D FT2018 U1 R1 4 Lbs 1.8 kg Lbs 1.2 kg unit FT2019 U1 R1 5 Lbs 2.3 kg Lbs 1.7 kg unit Infrastructure Building Products usa siemens com fire for Ordering Documentation Sheet Tabular Annunciator Black UL ULC PRO System Enclosures Tabular Annunciator Red PRO 50 point FACP Tabular Annunciator Black S54400 A146 A1 Tabular Annunciator Red S54400 C54 A1 S54400 C54 A2 Red Black no control Tabular no control Tabular no control Tabular Qty 1 Qty 1 Qty 1 Qty 1 Enclosure Kit Black Black Red no control Tabular Enclosure Kit Red Qty 1 Qty 1 Qty 1 Qty 1 Hardware Kit tabular annunciators Enclosure Canadian applications the 16 zone and 32 Tabular Annunciators are used optionally in provinces and can be utilized for display only order to comply with ULC regulations each annunciator with manual controls must be in a lockable ULC S527 Listed enclosure NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also

Related Files