Siemens DCT-1E Five Channel Digital Communicator, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Model DCT 1E Channel Digital Communicator 864 Listed Meets NFPA 72 Chapter 4 for Central Station Monitoring Listed as a Slave Communicator for Connection to 3TM SXL EX PXL MXL FS 100 and XLS Fire Alarm Control Panels Five Fully Supervised Input Channels or open collector Dual Phone Line Interface and Line Monitoring Automatic 24 Hour Test Reports in Contact ID SIA and 4 2 Formats 100 Event History Buffer Local Keypad Programmer DCT P Form cid 147 C cid 148 Relay Output for Trouble Conditions LEDs for Heartbeat System Trouble Phone Line Troubles Complete with enclosure Feature Building Technologies Inc Fire Safety Division the Model DCT 1E five channel dual line digital communication transmitter This communicator is to monitor UL listed fire alarm control panels from these fire alarm control panels drive the Programming and troubleshooting time is by user friendly English language messages with the Model DCT P local programmer Line Monitors phone line circuits detect phone line faults by their voltages Each line is monitored every seconds If a trouble condition persists through three cycles 36 seconds the DCT 1E sends a trouble to the central station turns on the yellow phone LED and operates the System Trouble Relay To phone line accessibility the DCT 1E is equipped line seizure Inputs supervised or unsupervised channel inputs can be as open collector inputs or contact closure The System 3TM using the CSI 35 module a combination of contact closures and active voltage input to activate the DCT 1E The FireFinder MXL SXL EX and PXL use a contact closure for channel input can be programmed as Fire Alarm Waterflow Supervisory Monitor Alarm System Fault AC or Low Battery All inputs are non latching will return to their normal state when the input is Functions power up DCT 1E performs a system status self A watchdog circuit on the microprocessor resets the if a failure occurs Additionally a 24 hour test can be programmed to a central station at a time The auto test will automatically alternate the two phone lines to ensure proper operation installer can also initiate a manual test using the programmer NUMBER Specifications DCT 1E cid 190 H x 5 W x 2 Deep Metal Cabinet Lb DCT P Programmer Annunciator harness H x 6 W x 1 Deep Than 1 Lb Information Model DCT P LCD keypad programmer can be connected to program or troubleshoot the on site It has a two line 16 character to provide information on various programming It is used to put account information phone line configurations input configurations and configurations into the DCT 1E It can also be for manual tests viewing history troubleshooting resetting the DCT 1E Monitoring Fire Safety Fire Alarm Control Panels as well as the communicator can be programmed to delay of this signal to a central station or remote as required by Underwriters cid 146 Laboratories The 3TM transmits this signal via an active high output the Model CSI 35 central station interface Specification cid 151 24 VDC from UL listed fire control panel DC Load cid 151 150mA cid 151 190mA Monitoring Input trouble output from System 3TM CSI 35 module or programmed as AC Fail on FireFinder XLS or MXL Output C rated 1A 30VDC Trouble Lights LED for System Heartbeat two 2 yellow LEDs for line status flashing during communication steady trouble one yellow LED for System Status flying leads for all power input and connections plug in connection point for programmer Formats via SIA 110 SIA 300 Contact ID 4 2 formats Requirements registration Number ESVMUL 46514 AL E of Jack RJ31X two required 864 listed by Siemens Fire Safety for use FireFinder XLS SXL EX MXL PXL and 3TM CSI 35 UL 864 listed NYMEA and approved by DSI for Central Station Remote Monitoring Building Technologies Safety Safety Fernwood Road Park NJ 07932 973 593 2600 973 593 6670 www sbt siemens com fis in U S A Safety Kenview Boulevard Ontario L6T 5E4 905 799 9937 905 799 9858 2002 Issue

Related Files